• Title/Summary/Keyword: Corona current

Search Result 211, Processing Time 0.024 seconds

Computation of Refractive Indices of Corona Viruses through Reverse Calculation

  • Kuppuswamy, Srinivasan;Swain, Kaliprasanna;Nayak, Suryakanta;Palai, Gopinath
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.566-570
    • /
    • 2020
  • The present paper computes the refractive indices of different corona viruses (H5N1, H5N2, H9N2, H4N6, FAdV and IBV) through reflectance analysis of a virus solution. The computational analysis indicates that the refractive indices of all viruses are negative at the signal of 412 nm. Further the numerical output shows that the infectious bronchitis viruses (family of novel corona viruses, COVID-19) have higher negative refractive indices as compared to other corona viruses. Finally refractive indices of the family of COVID-19 are investigated with respect to the EID (Electronic infusion Device) concentration of the viruses, showing that the refractive index which ranges from "-0.96725 to -0.999998" corresponds to '0.01 to 10000' EID virus concentration.

A Study on the Perception of Corona19 Period Play Culture Based on Big Data Analysis

  • Jung, Seon-Jin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.196-203
    • /
    • 2020
  • In this study, we tried to explore the actual direction for the play culture by looking at the social perception of the change of play culture due to the Corona 19 using big data analysis. For this research, we used Textom, a website specializing in collecting big data, and collected 10,216 data using keywords of "Corona + Play," "Play Culture" and "Leisure" from January 19, 2020 to September 30, 2020, when the first confirmed case of Corona 19 occurred in Korea on various portal sites at home and abroad. The results of this paper showed that the social perception of the play culture in Corona 19 was 51.61%, not much different from the negative image of 48.15%. It is necessary to develop a play culture program that can identify people's various desires and emotions under the premise that situations similar to the current With Corona period and Corona19 can occur at any time, and find mental and physical stability and vitality in unstable situations. In addition, the results of this study can be used as basic data for the development of play culture policies or programs, with the significance that this study helped vitalize big data utilization research in the fields of play, leisure, and culture.

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

Simulation of Corona Charging Process in Electret for Sensor Materials (센서재료용 일렉트렛트의 코로나 대전 과정 시뮬레이션)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.421-422
    • /
    • 2012
  • 본 연구에서는 코로나 대전된 고분자의 열자격전류(Thermally Stimulated Current; 이하 TSC) 데이터를 기반으로 코로나 대전 과정을 유한요소법(Finite Element Method; 이하 FEM)을 이용하여 시뮬레이션하였다. $DC -5{\sim}-8[kV]$의 고전압을 고분자에 인가하여 형성시킨 일렉트렛트를 온도 범위 $-100{\sim}+200[^{\circ}C]$에서 얻은 TSC 데이터의 대전 과정을 조사하기 위하여 FEM으로 시뮬레이션을 수행하여 공간에서 코로나 대전 과정을 추정하였다.

  • PDF

Simulation of Charging Process in Forming Electret for Sensor Material (센서재료용 일렉트렛트 형성에 대전과정 시뮬레이션)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.185-188
    • /
    • 2011
  • In order to estimate spatial charging process in the corona charging which has been used to make polymer electret, the electrical properties of polypropylene film were obtained from Thermally Stimulated Current(TSC) measurements after corona charging between knife electrode and cylinder electrode with the voltages of -5, -6, -7 and -8[kV], respectively. And then the electrostatic contour and the electric field vector were also simulated by using Finite Element Method(FEM). The edge effect around edge of knife electrode affected the electrostatic contour on surface of specimen and the electric field concentration inside specimen. The uneven charging state in the electret due to the mistake on design could be calculated and so the optimal design of corona charging device which is appropriate to various materials is come to be practicable.

  • PDF

Approach to Characterization of a Diode Type Corona Charger for Aerosol Size Measurement

  • Intra Panich;Tippayawong Nakorn
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.196-203
    • /
    • 2005
  • A semi-empirical method to determine the electrostatic characteristics of a diode type corona aerosol charger based on ion current measurement and electrostatic charging theory was presented. Results from mathematical model were in agreement with those from experimental investigation of the charger. Current-voltage characteristics, $N_{i}t$ product and charge distribution against aerosol size were obtained. It was shown that the space charge was significant and must be taken into account at high ion number concentration and low flow rate. Additionally, significant particle loss was evident for particles smaller than 20 nm in diameter where their electrical mobility was high. Increase in charging efficiency may be achieved by introducing surrounding sheath flow and applying AC high voltage. Overall, the approach was found to be useful in characterizing the aerosol charger.

1-Dimensional Simulation of the Corona Discharge using Fluid Method (유체법을 이용한 코로나 방전의 1차원 수치해석)

  • 이용신;심재학;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.172-176
    • /
    • 1997
  • It is likely that the corona discharge appears due to the motion and the multiplication of electron and ion under the nonuniform electric field. Because the motion and the multiplication of electron and ion are the function of electric field, for the simulation of the corona discharge, we have to calculate the electric field, before the calculation of the motion and the multiplication of electron and ion. In this paper, the electric field is calculated on the assumption that the gap between a hyperboloidal needle and a plane is 1-dimension, and the motion and the multiplication of electron and ion are determined by Flux-Corrected Transport method. For this purpose, we solve the electron and ion continuity equation together with Poisson equation. We calculated the current density and the electron and ion density distributions between electrodes as well as electric field distortion due to the space charge assuming that the discharge channel radius is 100${\mu}{\textrm}{m}$. In this simulation, it is found that the current density has one peak as observed by experiment, and electric field distortion is important to the formation and the stability of the corona discharge.

  • PDF

A Study on the Collection Characteristics of Submicron Particles in an Electrostatic Precipitator - I. Electrical Characteristics (전기 집진기에서의 Submicron 입자의 집진 특성에 관한 연구-I. 전기적 특성)

  • 김용진;황태근;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.572-578
    • /
    • 2001
  • This study conducts a laboratory measurement on a cylindrical electrostatic precipitator(ESP) with a 30mm-diameter cylinder. Several kinds of test aerosols are generated with an atomizer and a diffusion dryer. The effects of applied voltage, flow state, gas velocity, and gas temperature on the electrical characteristics of the precipitator and onset of corona are experimentally investigated. The corona onset voltage is decreased, as diameter of discharge electrode wire becomes small or temperature of the precipitator increases. As the fluid velocity or particle load in the precipitator increases, the corona current is decreased.

  • PDF

Improvement of Corona Temperature and Velocity Determination Method Using a Coronagraph Filter System

  • Cho, Kyuhyoun;Chae, Jongchul;Lim, Eun-Kyung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.85.3-86
    • /
    • 2017
  • We have developed a methodology to determine the coronal electron temperature and solar wind speed using a four filter coronagraph system. The method developed so far have been applied to total eclipse observation and have yielded plausible results. The current methodology starts from the assumption that 1) coronal free electrons are isothermal and 2) coronal free electrons have spherically symmetric distrubution. However, the actual solar corona differs significantly from the two assumptions above. The coronal electron density is not spherically symmetric due to streamers, plumes, and coronal loops, and the electron temperature is also expected to increase rapidly with distance from the sun. We will discuss how to determine the temperature and wind speed of the corona in the case of corona with thermal structures and non-spherical symmetric electron density.

  • PDF

Three-dimensional evolution of a solar magnetic field that emerges, organizes and produces a flare and flare-associated eruptions of a flux rope and plasmoid

  • Magara, Tetsuya
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.63.2-63.2
    • /
    • 2015
  • Solar flare is one of the energetic phenomena observed on the Sun, and it is often accompanied with eruptions such as global-scale eruption of a flux rope (filament/prominence eruption) and small-scale eruption of a plasmoid. A flare itself is a dissipative phenomenon where accumulated electric current representing free magnetic energy is dissipated quickly at a special location called a current sheet formed in a generally highly conductive solar corona. Previous studies have demonstrated how a solar magnetic field placed on the Sun forms a current sheet when magnetic shear is added to the field. Our study is focused on a self-consistent process of how a subsurface magnetic field emerges into the solar atmosphere and forms a current sheet in the corona. This study also gives light to a relation among a flare and two types of flare-associated eruptions; flux-rope eruption and plasmoid eruption.

  • PDF