• 제목/요약/키워드: Corona current

검색결과 211건 처리시간 0.024초

플라즈마 처리된 실리콘 절연재의 표면 특성화 (Surface Charcterization of plasma-treated silicone insulating materials)

  • 송정용;허창수;연복희;이태호;유형철;서유진;이기택;김남렬;이운하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.176-178
    • /
    • 2002
  • Surface states of silicone polymer treated by plasma were investigated by the analysis by x-ray photoelectron spectroscopy(XPS) and surface voltage decay after corona charging. Plasma treatment causes the silica -like oxidative layer, which was confirmed with XPS, and lowers surface resistivity with increasing the plasma treatment time. Using the decay time constant of surface voltage, the calculated surface resistivity was compared with the value directly measured by voltage-current method using three electrodes system. A good agreement between two methods was obtained. In addition, we estimated the thermal activation energy for surface conduction, Based on our results, we could understand the relationship between surface chemical states and surface electrical properties.

  • PDF

Corona-Cov-2 (COVID-19) and ginseng: Comparison of possible use in COVID-19 and influenza

  • Lee, Won Sik;Rhee, Dong-Kwon
    • Journal of Ginseng Research
    • /
    • 제45권4호
    • /
    • pp.535-537
    • /
    • 2021
  • In the 1918 influenza pandemic, more than 95% of mortalities were ascribed to bacterial pneumonia. After the primary influenza infection, the innate immune system is attenuated, and the susceptibility to bacteria is increased. Subsequent bacterial pneumonia exacerbates morbidity and increases the mortality rate. Similarly, COVID-19 infection attenuates innate immunity and results in pneumonia. In addition, the current pneumococcal conjugate vaccine may have limited defense against secondary pneumococcal infection after influenza infection. Therefore, until a fully protective vaccine is available, a method of increasing immunity may be helpful. Ginseng has been shown to increase the defense against influenza in clinical trials and animal experiments, as well as the defense against pneumococcal pneumonia in animal experiments. Based on these findings, ginseng is suspected to be helpful for providing immunity against COVID-19.

실증시험선로를 이용한 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 이온류 특성 평가 (Ion Effects of HVDC ±500 kV Double Bipole Overhead Transmission Line with Metallic Return Conductor Using Full-scale Test Line)

  • 신구용;권구민;주문노;우정민
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.249-256
    • /
    • 2019
  • 국내에 향후 건설 예정인 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 최적선로 형상을 설계하고 송전선로에서 발생되는 전기환경장해를 검증하기 위해 실증시험장을 구축하여 1년간 전기환경장해 평가시험을 수행하였다. 또한, HVDC Double Bipole 실선로에서 인체의 지표면 전계인지도 평가시험을 통해 HVDC 실규모 실증선로 직하에서 인체가 직류 전계를 감지하는 임계값을 조사하여 HVDC ±500 kV Double Bipole 가공송전선로의 직류전계 설계기준안의 타당성을 검증하였다. HVDC ±500 kV Double Bipole 시험선로의 극형상은 전기환경장해와 운영관점에서 동일한 극성을 대각으로 배치하였으며, 국내 가공송전선로의 전기환경장해의 사회적인 수용성을 고려하여 선로에서 코로나방전이 거의 발생되지 않도록 소도체 방식은 6 도체를 선정하였다. 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로 방식인 Cardinal×6B를 적용한 실증시험결과, 선로 도체에서 코로나 방전이 거의 발생되지 않았으며, 따라서 지표면 전계와 이온전류밀도는 모두 국내 가공송전선로 설계 기준값을 만족하였다. 또한 선로직하에서 피조사자들에 대한 전계 인지도 평가결과, 피조사자들의 70%는 23 kV/m에 노출되어도 직류전계를 인지하지 못하는 결과를 나타냈다.

전계해석과 기체방전 이론을 기반으로 한 Polyvinyl-Chloride-Sheathed Flat Cord 표면의 트래킹 진전 메커니즘 (Tracking Propagation Mechanism on the Surface of Polyvinyl-Chloride-Sheathed Flat Cord based on Electric Field Analysis and Gas Discharge Physics)

  • 임동영;박혜리;지승욱
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.30-38
    • /
    • 2019
  • 전기 화재의 주요 원인 중 하나인 트래킹은 전기적 방전에 의한 물리적 현상으로 인식된다. 따라서 트래킹은 전계해석, 전자생성에 의한 도전성 경로, 기체방전이론을 기반으로 설명되어야 한다. 하지만, 이러한 사항을 반영한 연구논문은 드물다. 본 논문은 트래킹 진전에서 그들의 영향을 포함한 트래킹 진전 메커니즘을 제안하였다. 그 메커니즘의 제안을 위해, 트래킹 실험, 탄화진전 모델에 대한 전계해석, 연면방전 이론을 적용한 트래킹 진전과정에 대한 설명이 수행되었다. 트래킹 모의실험으로부터, 코로나 방전에서 트래킹 파괴까지 트래킹 진전의 각 단계에서 전류파형이 측정되었다. 전계해석은 탄화의 발생과 진전과정동안 건조대 표면의 전계와 전자생성을 위한 고전계 영역을 파악하기 위해 수행되었다. 본 논문에서 제안된 트래킹 메커니즘은 코로나 방전에 의한 전자사태, 양이온의 축적, 전자사태의 확장, 2차 전자사태, 스트리머, 도전성 경로에 의한 트래킹 파괴의 6단계로 구성된다. 트래킹 모의실험에서 측정된 펄스성 전류파형은 제안된 트래킹 메커니즘에 의해 설명될 수 있었다. 본 연구 결과는 화재의 원인인 트래킹을 검출하고, 내트래킹성을 높이는 데 필요한 기술 자료가 될 것이다.

PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구 (A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity)

  • 이한얼;이광택;안소희;박예원;이건희;홍기정;박인용;김상복;박대훈;이예완;송동근;김용진;한방우;김학준
    • 한국입자에어로졸학회지
    • /
    • 제19권3호
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.

Application of a non-equilibrium ionization model to rapidly heated solar plasmas

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Shen, Chengcai;Moon, Yong-Jae;Kim, Yeon-Han
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.53.1-53.1
    • /
    • 2019
  • We apply a non-equilibrium ionization (NEI) model to a supra-arcade plasma sheet, shocked plasma, and current sheet. The model assumes that the plasma is initially in ionization equilibrium at low temperature, and it is heated rapidly by a shock or magnetic reconnection. The model presents the temperature and characteristic timescale responses of the Atmospheric Imaging Assembly (AIA) on board Solar Dynamic Observatory and X-ray Telescope (XRT) on board Hinode. We compare the model ratios of the responses between different passbands with the observed ratios of a supra-arcade plasma sheet on 2012 January 27. We find that most of observations are able to be described by using a combination of temperatures in equilibrium and the plasma closer to the arcade may be close to equilibrium ionization. We also utilize the set of responses to estimate the temperature and density for shocked plasma associated with a coronal mass ejection on 2010 June 13. The temperature, density, and the line of sight depth ranges we obtain are in reasonable agreement with previous works. However, a detailed model of the spherical shock is needed to fit the observations. We also compare the model ratios with the observations of a current sheet feature on 2017 September 10. The long extended current sheet above the solar limb makes it easy to analyze the sheet without background corona. We find that the sheet feature is far from equilibrium ionization while the background plasma is close to equilibrium. We discuss our results with the previous studies assuming equilibrium ionization.

  • PDF

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

$SF_6$$SF_6/CO_2$ 혼합기체 중에서의 뇌임펄스 전구방전의 특성 (Characteristics of lightning impulse pre-breakdown discharge in $SF_6\;and\;SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2005
  • This paper describes the experimental results of the pre-breakdown phenomena in $SF_6/CO_2$ mixtures under non-uniform electric fields caused by positive and negative lightning negative voltages. $SF_6/CO_2$ mixtures have an advantage of an environmental aspect and cost reduction, and safety aspects. In order to analyze the pre-breakdown processes in $SF_6/CO_2$ mixtures stressed by impulse voltages, pre-breakdown current and luminous signals were measured by a shunt and a photo-multiplier tube, respectively. Dielectric strengthes of $SF_6/CO_2$ mixtures were investigated. Additionally, characteristics of discharge channels were observed by high speed cameras and the physical properties were discussed. The pre-breakdown propagates with a stepwise process. The in to breakdown from the corona onset point in positive polarity was shorter than that in negative polarity. The time intervals of positive leaders are shorter than those of negative leaders, and the path of positive leader channel is zigzag.

  • PDF

대기압 글로우 방전의 구현 및 안정화에 대한 실험적 연구 (An Experimental Study on the Implementation and Stabilization of Atmospheric Pressure Glow Discharge)

  • 최상원
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.42-46
    • /
    • 2008
  • Ionizers are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, ultraviolet and glow discharge. Glow discharge has lots of attractive properties, such as lower discharge sustaining voltage, no generation of ozone, and so on. In this paper, we did an experimental study to trace the mechanism and stabilization of atmospheric pressure glow discharge using the several size and shape of electrodes. As an experimental result, to sustain conditions of atmospheric pressure glow discharge is that discharge voltage is 360V, discharge current is 12mA, apply frequency is 1kHz between electrodes when positive electrode is molybdenum(Mo) and negative electrode is copper(Cu). We confirmed that the mechanism and stabilization of atmospheric glow discharge is deeply concerned with the shape and material of electrode for discharge. Especially, glow discharge in atmospheric pressure was well generated and sustained according with the physical properties used electrode materials, example melting point, thermal conductivity, and etc.

전기철도 전차선로의 설치 상태 판단을 위한 복합검측 기술 구현 (Implementation of Multi-functional Type Condition Monitoring System for Railway Catenary Systems)

  • 박영;이기원;박신영;박준영;최원석
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1406-1410
    • /
    • 2015
  • The railway catenary systems consist of a complex structure, electrical and mechanical conditions are exposed to dangerous environment due to current collection between pantograph and catenary systems. These two types of conditions for the catenary systems are critically assessed for management and are becoming increasingly more dependent on reliable inspection system. In this paper, a new measurement system which enables inspection of catenary faults was studied and implemented. The system uses wavelength band of ultraviolet (UV) and IR (Infrared) to measure the insulation of corona and temperature of catenary wire. In order to determine the sensitivity of implemented system, the performance test such as distance detection range of UV camera and temperature resolution of IR camera were conducted, respectively. The field test of development system was also conducted in metro and high-speed line using mobile type UV and IR multi-composited measurement systems.