• 제목/요약/키워드: Corona current

검색결과 211건 처리시간 0.03초

발전기 정지중 진단을 위하여 개발된 유도결합 마그네틱 프로브의 성능특성 (Performance Characteristics of an Inductively Coupled Magnetic Probe Developed for Off-line Monitoring of a Rotating Machine)

  • 박노준;양상현;공태식;김희동;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.46-46
    • /
    • 2010
  • In order to detect exact corona discharge point at stator winding of a rotating machine, an inductively coupled magnetic probe has been developed, which consists of U-shaped and truncated manganese ferrite inductor as a helix. The measured current intensity is somewhat higher than commercially developed probe. It has been shown that the measured intensity of proposed probe is suitable for manual localization as to off-line stator winding monitoring of rotating machine.

  • PDF

The Relation Between Magnetic Field Configuration And The Flux Expansion Factor

  • 이환희;;안준모;강지혜
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.85.1-85.1
    • /
    • 2012
  • In this study we use three-dimensional magnetohydrodynamic simulations of flux emergence from solar subsurface layer to corona. In order to study the twist parameter of magnetic field we compare the simulations for strongly twisted and weakly twisted cases. Based on the results, we derive a flux expansion factor of selected flux tubes which is a ratio of expanded cross section to the one measured at the footpoint of the flux tube. To understand the effect of flux expansion factor, we make a comparison between magnetic field configuration and the expansion factor. By using a fitting function of hyperbolic tangent we derive noticeable correlations among the strength of the vertical magnetic field, current density and expansion factor. We discuss what these results tell about the relationship between the twist of emerging field and the mechanism for the solar wind.

  • PDF

대기중 연소화염에 의한 교류 플래시오버전압의 저하 특성 (Reduction Characteristics of AC Flashover Voltage by Combustion Flames under Atmospheric Conditions)

  • 김인식
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1041-1047
    • /
    • 2001
  • In this paper, reduction characteristics of the ac flashover voltage in the horizontal air gap of sphere-sphere/needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrodes. The voltage and current waveforms were measured, when the flashover is occurred, in order to examine the flashover polarity by flame. The reduction characteristics of ac flashover voltage were discussed with the thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that changed by the corona wind and coulomb\`s force. As the results of an experimental investigation, It was found that the reduction of flashover voltages in sphere-sphere system, in comparison with the no-flame case, are 79.9 [%] for k=0, 82.9 [%] for k=0.5, 87.5 [%] for k=1.0, 85.0 [%] for h=0 [cm], 40.8 [%] for h=5 [cm] and 28.2 [%] for h=9 [cm] when ac voltage is applied.

  • PDF

대용량 터빈발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Large Turbine Generator Stator Windings)

  • 김희동;이영준;박덕현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2093-2096
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in three large turbine generators. Nondestructive tests have been carried out on stand-still generators which have been in service for 2 to 30 years. In most cases these tests include ac current increase rate($\Delta$I), delta tan delta( ${\Delta}tan{\delta}$), and maximum partial discharge(Qm). Gen. 2 show that the $tan{\delta}$ is higher than other two generators in the $tan{\delta}$-voltage curve. Partial discharge(PD) patterns were observed internal, corona and treeing discharges in large turbine generators. The PD tests were confirmed the correlation between discharge patterns and the kinds of defects.

  • PDF

전기집진에서의 난류 입자 이산 (Turbulent Particle Dispersion Effects on Electrostatic Precipitation)

  • 최범석
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.39-47
    • /
    • 1998
  • Industrial electrostatic precipitation is a very complex process, which involves multiple-way interaction between the electric field, the fluid flow, and the particulate motion. This paper describes a strongly coupled calculation procedure for the rigorous computation of particle dynamics during electrostatic precipitation. The turbulent gas flow and the particle motion under electrostatic forces are calculated by using the commercial computational fluid dynamics (CFD) package FLUENT linked to a finite-volume solver for the electric field and ion charge. Particle charge is determined from both local electrical conditions and the cell residence time which the particle has experienced through its path. Particle charge density and the particle velocity are averaged in a control volume to use Lagrangian information of the particle motion in calculating the gas and electric fields. The turbulent particulate transport and the effects of particulate space charge on the electrical current flow are investigated. The calculated results for poly-dispersed particles are compared with those for mono-dispersed particles, and significant differences are demonstrated.

  • PDF

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

유한요소법을 이용한 침대 평판 전극에서의 $SF_6$ 가스 방전 특성 해석 (A study on the discharge characteristics of $SF_6$ gas by Finite Element Methods in needle to plane electrode)

  • 현정수;박필용;최승길;심재학;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.700-703
    • /
    • 1999
  • Thls paper describes the process of corona discharge in $SF_6$ gas. The discharge characteristm such as electric field distribution, electron density, ion density and current denslty distribution are considered as time go by, The result show that difference between electronegative gas and nonelectronegative gas.

  • PDF

광폭 전기집진기의 집진 특성에 관한 수치적 연구 (A Numerical Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator)

  • 김용진;홍원석;정상현;하병길;하대홍;유주식
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1205-1213
    • /
    • 2001
  • The electrical characteristics and particle collection efficiency of a wide-plate spacing electrostatic precipitator are numerically investigated, and the results are compared with those obtained experimentally. The electric potential and field strength near the collection plate increase with increasing the plate spacing. The electric field strength of a discharge electrode of a twisted pin type is larger than that of a rectangular type. As the roughness factor of the discharge electrode wire becomes small, or the plate spacing becomes narrow, the corona current of the precipitator increases. The numerical results agree well with those obtained from experimental method.

  • PDF

불평등전장에서 $SF_6$$SF_6/N_2$ 혼합기체의 뇌임펄스 전압에 대한 코로나 방전특성 (Characteristics of lightning impulse corona discharges under non-uniform electric fields in $SF_6$ and $SF_6/N_2$ mixtures)

  • 이복희;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.129-132
    • /
    • 2004
  • This paper presents an experimental study on the prebreakdown characteristics in $SF_6/N_2$ mixtures under non-uniform electric fields when subjected to the positive and negative lightning impulse voltages. $SF_6/N_2$ mixtures have a merit of an environmental aspect and cost reduction, and safty aspects. In order to analyze the prebreakdown processes in $SF_6/N_2$ mixtures stressed by impulse voltages, prebreakdown current and light were observed by a shunt with high sensitivity and a photo-multiplier tube, respectively. Additionally, characteristics of luminous events in flashovers were discussed.

  • PDF

6.6kV 회전기 고정자 권선에서 부분방전 진단을 위한 평판 안테나 센서 설계 (The Design of a Planar Antenna Sensor for Partial Discharge diagnosis in 6.6kV Rotary Machine Stator Windings)

  • 임광진;키아우소륀;신동훈;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.222-223
    • /
    • 2007
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which tranmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analize the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF