• 제목/요약/키워드: Corner point

검색결과 193건 처리시간 0.021초

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

1990년대 유압굴삭기 조형 분석에 관한 연구 (Design Analysis of Hydraulic Excavator since 1990)

  • 윤진필;문무경
    • 디자인학연구
    • /
    • 제13권4호
    • /
    • pp.233-242
    • /
    • 2000
  • 1990년대는 유압굴삭기의 전통적 조형이 새롭게 모색 및 재해석되는 시기로 판단되었으며, 이는 2가지 방향으로 정리될 수 있다. 하나는 유압굴삭기의 전통적 이미지에 관한 부정적 해석에서 기인한 '탈(post-heavy equipment)중기적' 경향이며, 다른 하나는 고유성 유지와 개선이라는 긍정적 해석에서 기인한 '후기(late-)중기적' 경향이다. 이는 동일한 현상을 다양하게 바라볼 수 있는 패러다임과 관련하는 것으로 사료된다. 이 시기에 개발 및 시판된 8개 연구대상 모델 중 유압굴삭기의 조형 경향은, 일본 색채디자인연구소에서 개발한 이미지스케일 3상한에서 2상한으로 변화였으며, 예외적으로 코벨코는 1상한까지 이동하는 경향이 있었다. 이는 탈중기적 이미지를 디자인 전략으로 채택하고 있는 코벨코만의 경우였다. 아울러, 인적(入的)공간으로서의 캐빈의 변화는 장비 전체의 변화에서보다 좀더 1상한으로 이동하고 있는데, 이는 물적(物的)공간과 시각적 차별화를 위한 것으로 사료되었다.

  • PDF

다양한 카메라와 조명의 변화에 강건한 반자동 카메라 캘리브레이션 방법 (Robust Semi-auto Calibration Method for Various Cameras and Illumination Changes)

  • 신동원;호요성
    • 방송공학회논문지
    • /
    • 제21권1호
    • /
    • pp.36-42
    • /
    • 2016
  • 최근 다시점 카메라 시스템을 기반으로 한 3차원 영상 렌더링 방법을 통해 3차원 콘텐츠가 많이 제작되고 있다. 이러한 깊이 영상 기반 렌더링에서는 필연적으로 색상 카메라와 깊이 카메라 간의 시점 차이가 발생하기 때문에 두 카메라의 시점을 일치시키는 전처리 과정으로서 카메라 파라미터가 중요한 역할을 수행한다. 기존의 카메라 캘리브레이션 방법은 평면의 체스보드 패턴을 회전과 이동이 수행된 여러 자세로 촬영한 다음 획득된 영상에서 패턴 특징 점을 손으로 직접 선택해야하는 불편함이 따른다. 따라서 본 논문에서는 이 문제를 해소하기 위해 원형 샘플 화소 검사와 호모그래피 예측을 이용한 반자동 카메라 캘리브레이션을 제안한다. 제안하는 방법은 먼저 FAST 코너 검출 알고리즘을 이용하여 패턴 특징 점의 후보를 영상으로부터 추출한다. 다음으로 원형 샘플 화소를 검사하여 후보군의 크기를 줄이고 호모그래피 예측을 통해 손실된 패턴 특징 점을 보완하는 완전한 패턴 특징 점군을 획득한다. 마지막으로 쌍곡 포물면 근사를 통해 실수 단위의 정확성을 가지는 패턴 특징 점의 위치를 획득한다. 실험을 통해 각 단계에서 어떤 요인이 패턴 특징 점 검출에 영향을 미치는가에 대해 조사했고 제안하는 방법이 기존의 방법과 비교하여 카메라 파라미터의 정확성은 유지하고 수작업의 불편함을 해소할 수 있음을 확인했다.

대형선박용 유압실린더에서 경제요소법을 이용한 응력해석 (Analysis on the Stress of Hydraulic Cylinder for Large Vessel by Boundary Element Method)

  • 김옥삼
    • 수산해양기술연구
    • /
    • 제31권4호
    • /
    • pp.423-434
    • /
    • 1995
  • 수산업분야의 생력화와 조업공정의 단축으로 새로운 활로를 개척할 수 있는 방안으로 보조기계들의 유압화 및 대형화에 사용되는 후벽 유압실린더는 작동응력 거동의 분석과 파손예측의 정확성이 강구되어야만 기계고장으로 인한 해난사고의 개연성을 미연에 감소시킬 수 있다. 균일한 내압을 받는 대형선박용 유압실린더를 수치해석적 방법인 경계요소법을 사용하여 각종 응력 해석의 시도는 엄밀해나 유한요소법의 결과와 비교적 양호하게 일치하고 있다. 축대칭 형상에 대한 반경방향 응력이나 원주방향 응력의 BEM 해석결과는 단일절점과 이중절점 모두 최대 25MPa의 압축응력이나 최대 52MPa의 인장응력이 작용하고 있으므로 재료의 허용응력내에서 작동하고 있음을 알 수 있다. 이중절점 형상함수(double node shape function)를 사용하여 원통형 형상의 구조물에 대한 수치계산 결과의 정확도를 높힐수 있었으며 입력데이터의 증가는 오차감소에 기여하였으나 프로그램의 실행시간(run-time)을 증가시켰다. 코너에서의 트랙션벡터의 불연속 현상을 해결하기 위한 이중절점의 사용은 영역 내부해의 안정성을 확보하였고 경계부근에서의 내부해의 발산을 제거하기 위한 이중지수형 적분법 사용은 해석결과의 오차를 효과적으로 감소시켰다.

  • PDF

치아파절에 관한 3차원유한요소법적 연구 (A STUDY ON TOOTH FRACTURE WITH THREE DIMENSIONAL FINITE ELEMENT METHOD)

  • 조병훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.291-316
    • /
    • 1993
  • Restorative procedures can lead to tooth fracture due to the relatively small amount of the remaining tooth structure. It is essential to prevent fractures by having a clear concept of the designs for cavity preparations. Among the several parameters in cavity designs, profound understanding of isthmus width factor would facilitate selection of the appropriate cavity preparation for a specific clinical situation. In this study, MO amalgam cavity were prepared on maxillary first premolar and filled with amalgam. Three dimensional, model with 1365 8-node brick elements was made by serial photographic method. In this model, isthmus was varied in width at 1/4, 1/3, 1/2 and 2/3 of intercuspal width and material properties were given for three element groups, i.e., enamel, dentin and amalgam. A load of 500 N was applied vertically on amalgam and enamel. In case of enamel loading, 2 model (with and without amalgam) was compared to consider the possibility of play at the interface between tooth material and amalgam. These models were analyzed with three dimensional finite element method. The results were as follows: 1. The stress was concentrated on the facio-pulpal line angle and distal marginal ridge of the cavity. 2. With the increase of the isthmus width, the stress spread around the facio-pulpal line angle and the area of stress concentration moved toward the proximal box. 3. In case of narrow isthmus width, the initiation point of crack would be in the area of isthmus corner of the cavity, and with the increase of the isthmus width, it would move toward the proximal box and at the same time the possibility of crack increase at the distal marginal ridge. 4. The direction of crack progressed outward and downward from the facio-pulpal line angle, and with the increase of the isthmus width, it approximated vertical direction. At the marginal ridge, it occurred in vertical direction. 5. It would be favorable to make the isthmus width narrower than a third of the intercuspal width, and to cover the cusp if isthmus width were wider than half of the intercuspal width. 6. It is necessary to apply the possibility of play to the finite element analysis.

  • PDF

네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석 (Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study)

  • 전상제;박정길;김현철;우성관;김광훈;손권;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.359-370
    • /
    • 2006
  • 본 연구의 목적은 네 가지 형태의 비우식성 치경부 병소에 과다한 교합하중을 가했을 때 각 와동에 나타나는 응력 분포를 3차원적으로 조사하고자 하였다. 임상적으로 많이 관찰되는 다양한 형태의 병소 중 4가지 형태의 서로 다른 병소를 대표적으로 선택하여 발치된 상악 제2소구치에 3차원 유한요소 모형을 제작하였다. 형성된 모형에 협측교두와 설측교두에 500 N의 하중을 가한 후 치경부병소 첨부와 수직 절단면의 주 응력을 분석하여 다음과 같은 결과를 얻었다. 1 서로 다른 네 가지 형태의 와동에서 응력분포 양상은 비슷했지만 응력의 크기가 서로 달랐다. 2. 최대치 응력은 근심협측 우각부에서 나타났으며, 또한 병소의 첨부에 응력의 집중을 보였다. 3. 하중 A에서는 주된 응력이 압축 응력이었고 하중 B에서는 주된 응력이 인장 응력이었다. 4. 이러한 하중 하에서 수복치료를 하지 않으면 와동의 크기는 점차 커지고 치아구조에는 유해하게 작용하리라 생각된다.

대형 깊은 기초의 지지거동 특성에 관한 연구 (A Study on the Behavior Characteristics of Large Deep Foundations)

  • 박춘식;정광민
    • 한국지반신소재학회논문집
    • /
    • 제19권1호
    • /
    • pp.83-91
    • /
    • 2020
  • 본 연구에서는 대형 구조물 기초 및 교량 하부기초로 사용이 증가되고 있는 현장타설말뚝 및 대형 Caisson 기초의 지반조건 변화에 따른 지지거동 특성에 대하여 분석하였다. 현장타설말뚝의 항복하중 분석법을 이용하여 산정한 허용지지력은 각 방법마다 서로 유사한 허용지지력을 산정하는 것으로 분석되었다. 또한 극한하중 분석법으로 산정한 허용지지력은 각 방법에 따라 지지력의 차이가 큰 것으로 분석되었고, 기존의 유사 사례현장을 분석하여 재하하중과 침하량에 관한 관계를 제시하였으며, 이를 통하여 향후 설계 및 시공시 말뚝의 침하특성을 평가하기 위한 경험식으로 유용하게 활용 가능할 것으로 판단된다. 또한 대형케이슨의 침설시 발생하는 지반반력 분포에 대해 검토한 결과 풍화암층 구간은 기초 모서리부에서 항복이 발생된 후 지반반력이 감소하여 거의 일정한 지반반력 분포를 나타내었으며, 기반암층 구간에서는 중앙부의 지반반력 증가로 인해 기초 중앙부가 아래로 볼록한 형태의 지반반력 형태로 변형되었다. 이와 같은 결과를 이용하여 Fang(1991) 및 Kőgler(1936)가 기존에 제시한 이론을 증명하였다.

2차원 스마트폰형상에 있어서 상징적 기능으로서 아날로그이미지 및 디지털이미지의 인지특성 연구 (A Study on the Cognitive Characteristics of Analog Image and Digital Image as a Symbolic Function in the Two-Dimensional Smartphone Form)

  • 이진승;김진성
    • 한국HCI학회논문지
    • /
    • 제13권3호
    • /
    • pp.17-33
    • /
    • 2018
  • 사람들은 시각을 통해 대상물의 형상, 크기, 색, 표면 재질 등과 같은 미적기능을 처리하는 것과 동시에 과거의 자신의 경험을 결합시켜 새로운 심리적 해석을 통한 상징적 기능으로서 대상물을 바라보기도 한다. 그렇기 때문에 단순히 사람들이 눈을 통해서 무엇을 보고 있느냐가 중요 한 것이 아니라 눈으로 받아들이고 이해한 것이 사람들에게 어떤 생각과 느낌과 심리적인 영향을 불러오는 것인가를 연구하고 이해하는 것이 매우 중요하다고 할 수 있겠다[15]. 이러한 연구목적의 하나로서 본 연구에서는 상징적 기능으로서 아날로그 이미지와 디지털 이미지의 인지적 특성이 무엇인지를 "형태적 관점"에서 디테일하게 밝혀내려 하였다. 그리고 다섯 가지 가설을 세우고 다음과 같은 실험을 진행하여 가설을 검증하였다. 우리주변에서 가장 많이 사용되고 있는 스마트폰을 2차원형상의 선화(線?)로 단순화하고 그 스마트폰 2차원형상의 가로라인에 R(radius)값이 부여되었을 경우와 런인알(run-in-r; radius)이 부여되었을 경우 그리고 그 도형들의 모서리에 R(radius)굴림이 적용 되었을 경우를 설정하고 12가지 짝(pair)을 이룬 도형의 조합을 실험방법으로 고안하여 피험자들에게 실험을 실시하였다. 그 결과 몇 가지 인간의 특징적인 현상을 발견할 수 있었으며, 특히 어떤 형상에서 사람들은 상징적 기능으로서의 아날로그이미지와 디지털이미지를 심리적으로 강하게 인지하는지를 객관적으로 검증할 수 있었다. 이와 같은 연구를 통해 얻어진 사람들의 생각과 느낌들을 확정된 하나의 가치로서 데이터베이스화 하여 제품디자이너들에게 제공할 수 있다면 소비자들이 원하는 기초적인 감성 디자인으로서 디자인형상에 응용할 수 있을 것으로 생각된다.

  • PDF

논의 양분유출 저감을 위한 저류지 효과 (Small-Scale Pond Effects on Reducing Pollutants Load from a Paddy Field)

  • 김민경;권순익;정구복;홍성창;채미진;윤순강;소규호
    • 한국환경농학회지
    • /
    • 제32권4호
    • /
    • pp.355-358
    • /
    • 2013
  • 논에서의 비점오염원 관리는 배출수 관리방안이 현실적인 방안으로 판단되어 본 연구에서는 논 배수 저감을 위한 저류지 효과를 구명하고자 2012년 5월부터 9월까지 경기도 수원시 권선구 서둔동 국립농업과학원 기후변화생태과 시험포장($1,715m^2$)에서 배수로 말단에 논 저류지($12m^2$)를 조성하였다. 영농기간 동안 강우사상시 저류지 유입 전인 논 배출수와 저류지를 통과한 배출수의 토사 및 양분물질(질소, 인) 부하량을 평가하여 저류지의 효과를 평가하였다. 영농기간 동안 논 저류지를 이용한 논 배출수 중 수질농도는 SS와 $COD_{Mn}$은 각각 79.3%와 45.6% 저감되었고 T-N과 T-P는 각각 52.2%와 60.5% 저감되었다. 또한 저류지를 이용한 월별 논 배출수의 유출량 및 양분물질 부하는 유출량의 경우 96~100% 저감되었고 T-N과 T-P의 부하량은 각각 16.3~73.0%와 15.4~70.1% 저감되었다. 따라서 경지기반 정리되어 용수의 취 배수가 용이한 논에서는 외부 수계로 배출되기 전 저류지를 설치하면 양분물질의 배출이 저감될 것으로 생각되며 특히 농업보호구역 및 농업진흥지역에는 논 배수 저류시설 등의 자연 정화형 비점오염 저감방안을 마련하도록 정책부서의 제도 개선이 필요하다고 생각된다.

Changes of lip morphology following mandibular setback surgery using 3D cone-beam computed tomography images

  • Paek, Seung Jae;Yoo, Ji Yong;Lee, Jang Won;Park, Won-Jong;Chee, Young Deok;Choi, Moon Gi;Choi, Eun Joo;Kwon, Kyung-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.38.1-38.10
    • /
    • 2016
  • Background: The aims of this study are to evaluate the lip morphology and change of lip commissure after mandibular setback surgery (MSS) for class III patients and analyze association between the amount of mandibular setback and change of lip morphology. Methods: The samples consisted of 14 class III patients treated with MSS using bilateral sagittal split ramus osteotomy. Lateral cephalogram and cone-beam CT were taken before and about 6 months after MSS. Changes in landmarks and variables were measured with 3D software program $Ondemand^{TM}$. Paired and independent t tests were performed for statistical analysis. Results: Landmarks in the mouth corner (cheilion, Ch) moved backward and downward (p < .005, p < .01). However, cheilion width was not statistically significantly changed. Landmark in labrale superius (Ls) was not altered significantly. Upper lip prominence angle (ChRt-Ls-$ChLt^{\circ}$) became acute. Landmarks in stomion (Stm), labrale inferius (Li) moved backward (p < .005, p < .001). Lower lip prominence angle (ChRt-Li-$ChLt^{\circ}$) became obtuse (p < .001). Height of the upper and lower lips was not altered significantly. Length of the upper lip vermilion was increased (p =< 0.01), and length of the lower lip vermilion was decreased (p < .05). Lip area on frontal view was not statistically significantly changed, but the upper lip area on lateral view was increased and change of the lower lip area decreased (p > .05, p < .005). On lateral view, upper lip prominent point (UP) moved downward and stomion moved backward and upward and the angle of Ls-UP-Stm ($^{\circ}$) was decreased. Lower lip prominent point (LP) moved backward and downward, and the angle of Stm-LP-Li ($^{\circ}$) was increased. Li moved backward. Finally, landmarks in the lower incisor tip (L1) moved backward and upward, but stomion moved downward. After surgery, lower incisor tip (L1) was positioned more superiorly than stomion (p < .05). There were significant associations between horizontal soft tissue and corresponding hard tissue. The posterior movement of L1 was related to statistically significantly about backward and downward movement of cheilion. Conclusions: The lip morphology of patients with dento-skeletal class III malocclusion shows a significant improvement after orthognathic surgery. Three-dimensional lip morphology changes in class III patients after MSS exhibited that cheilion moved backward and downward, upper lip projection angle became acute, lower lip projection angle became obtuse, change of upper lip area on lateral view was increased, change of lower lip area decreased, and morphology of lower lip was protruding. L1 was concerned with the lip tissue change in statistically significant way.