• 제목/요약/키워드: Cores

검색결과 1,545건 처리시간 0.031초

The effect of young stellar populations in Early-type galaxies

  • 서혜원;정현진;오규석;이석영
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.74.1-74.1
    • /
    • 2010
  • We have investigated the radial g-r color gradients of early-type galaxies in the Sloan Digital Sky Survey (SDSS) DR6 in the redshift range 0.00$H{\beta}$ absorption-line strengths and/or emission-line ratios that are indicative of the presence of young stellar populations. This implies that most of the residual star formation in early-type galaxies is centrally concentrated. Blue-cored galaxies are predominantly low-velocity dispersion systems. A simple model shows that the observed positive color gradients are visible only for a billion years after a star formation episode for the typical strength of recent star formation. The observed effective radius decreases and the mean surface brightness increases due to this centrally concentrated star formation episode. As a result, the majority of blue-cored galaxies may lie on different regions in the fundamental plane (FP) from red-cored ellipticals. However, the position of the blue-cored galaxies on the FP cannot be solely attributed to recent star formation but requires substantially lower velocity dispersion. We conclude that a low-level of residual star formation persists at the centers of most of low-mass early-type galaxies, whereas massive ones are mostly quiescent systems with metallicity-driven red cores.

  • PDF

비표준형 실린더 공시체에 대한 콘크리트 압축강도의 크기효과 (Size Effect of Compressive Strength of Concrete for the Non-standard Cylindrical Specimens)

  • 김진근;어석홍;이성태
    • 콘크리트학회지
    • /
    • 제9권1호
    • /
    • pp.105-113
    • /
    • 1997
  • 콘크리트 실린더 공시체의 크기에 따른 압축강도의 감소현상은 많은 관심을 받아 왔으나, 지금까지도 이에 대해 제시된 모델식이 없는 실정이다. 기존의 연구결과에 의하면 콘크리트의 강도는 부재의 크기가 증가할수록 감소하며 그 파괴거동을 규명하기 위해서는 비선형 파기역학 이론을 적용해야 함을 알 수 있다. 이전의 연구에서 표준형 콘크리트 실린더 공시체의 크기에 따른 압축강도의 변화를 파괴역학 이론에 따라 연구하고 실용적인 예측 모델식을 제시한 바 있다. 이 논문에서는 높이/직경의 비가 2/1이 아닌 비표준형 실린더 공시체를 고려하여 보다 일반적인 실린더 압축강도 에측 모델식을 제시하고자 한다. 이를 위하여 최대골재크기가 미소균열영역에 미치는 영향을 이론적으로 고찰하였으며, 특성길이의 개념을 새로이 도입하여 일반화된 크기효과에 대한 모델식을 제시하였다. 이 연구의 결과는 기존 구조물에서 채취한 다양한 크기의 콘크리트 코아 강도 등을 예측하는데도 매우 실용적으로 사용될 수 있을 것이다.

마이크로웨이브 발열거푸집으로 양생된 콘크리트의 압축강도발현 모델 (Compressive Strength Development Model for Concrete Cured by Microwave Heating Form)

  • 고태훈;문도영;배정명;유정훈
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.669-676
    • /
    • 2015
  • 본 연구에서는 촉진양생기술 중 하나인 마이크로웨이브 발열거푸집으로 양생된 콘크리트의 재령에 따른 압축강도를 예측할 수 있는 모델을 제시하였다. 제시된 모델은 ACI 209R-92에서 제시하고 있는 모델식과 유사하지만 시멘트종류와 양생방법에 따른 계수를 실험과 그 결과의 회귀분석에 근거하여 수정하여 제안하였다. 실험실 규모의 실험체를 타설한 후 마이크로웨이브 발열거푸집으로 촉진양생한 후 실험체로부터 채취된 코어의 압축강도를 측정하였다. 측정강도결과는 표준코어강도와 현장 콘크리트강도로 보정되었으며, 이 자료를 근거로 회귀분석을 수행하였다.

Comparison of prosthetic models produced by traditional and additive manufacturing methods

  • Park, Jin-Young;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Jae-Hong;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.294-302
    • /
    • 2015
  • PURPOSE. The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). MATERIALS AND METHODS. Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (${\alpha}=.05$). RESULTS. The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. CONCLUSION. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.

TBM 굴진성능 예측을 위한 NTNU 시험결과의 분석 (Statistical analysis of NTNU test results to predict rock TBM performance)

  • 장수호;최순욱;이규필;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제13권3호
    • /
    • pp.243-260
    • /
    • 2011
  • 성공적인 TBM의 적용을 위해 설계단계에서 TBM의 굴진성능을 사전에 예측하는 것이 매우 중요하다. 대표적인 TBM 굴진성능 예측모델 중의 하나인 NTNU 모델에서는 TBM의 시추코어를 활용한 세 가지 시험들로부터 얻어지는 DRI와 CLI에 근거히여 TBM의 굴진율과 디스크커터의 수명 예측이 가능하다. 본 연구에서는 NTNU모델의 기본 입력변수인 DRI와 CLI를 측정하는 NTNU 시험방법과 국내에서 구축된 NTNU 시험장비를 소개하고, 구축된 장비를 사요하여 측정된DRl와 CLI를 일축압축강도, 석영함유량 등익 암석 특성과 비교 분석하여 각각의 상관관계를 도출하였다. 마지막으로 NTNU의 시험 데이터베이스와의 비교를 통하여 국내에서 수행된 NTNU 시험결과의 신뢰성을 확인하였다.

Utility of Digital Rectal Examination, Serum Prostate Specific Antigen, and Transrectal Ultrasound in the Detection of Prostate Cancer: A Developing Country Perspective

  • Kash, Deep Par;Lal, Murli;Hashmi, Altaf Hussain;Mubarak, Muhammed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권7호
    • /
    • pp.3087-3091
    • /
    • 2014
  • Purpose: To determine the utility of digital rectal examination (DRE), serum total prostate specific antigen (tPSA) estimation, and transrectal ultrasound (TRUS) for the detection of prostate cancer (PCa) in men with lower urinary tract symptoms (LUTS). Materials and Methods: All patients with abnormal DRE, TRUS, or serum tPSA >4ng/ml, in any combination, underwent TRUS-guided needle biopsy. Eight cores of prostatic tissue were obtained from different areas of the peripheral prostate and examined histopathologically for the nature of the pathology. Results: PCa was detected in 151 (50.3%) patients, remaining 149 (49.7%) showed benign changes with or without active prostatitis. PCa was detected in 13 (56.5%), 9 (19.1%), 26 (28.3%), and 103 (74.6%) of patients with tPSA <4 ng/ml, 4-10 ng/ml, 10-20 ng/ml and >20 ng/ml respectively. Only 13 patients with PCa had abnormal DRE and TRUS with serum PSA <4 ng/ml. The detection rate was highest in patients with tPSA >20 ng/ml. The association between tPSA level and cancer detection was statistically significant (p<0.01). Among 209 patients with abnormal DRE and raised serum PSA, PCa was detected in 128 (61.2%). Conclusions: The incidence of PCa increases with increasing serum level of tPSA. The overall screening and detection rate can be further improved by using DRE, TRUS and TRUS-guided prostate needle biopsies.

PCS(Pressure Core Sampler) 개발 및 성능평가실험 (Development of PCS and an experiment for performance evaluation)

  • 이하정;김해진;이계광;정효석;손인락
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.973-980
    • /
    • 2015
  • 비전통 에너지자원은 전통 에너지자원에 비해 지리적으로 넓은 지역에 걸쳐 연속적인 형태로 분포되어 있으나, 잔존 기술적 회수가능 자원량(TRR : Technical Recoverable Resource)은 전통자원과 비슷하여 그 개발이 확대되고 있으며, 특히 셰일가스, 치밀가스, 석탄층 메탄가스, 가스하이드레이트 등의 비전통 가스자원의 개발이 활기를 띄고 있다. 그러나 현재의 물리검층 기술로는 비전통 자원에 포함된 물성, 특히 가스의 함량을 정확히 계산하기 어려우며 관련 기자재 또한 일부 해외 업체에서 독점하고 있다. 따라서 본 연구에서는 지하심부의 시료채취 순간부터 그 지점의 심부압력을 유지하여 시료 내 가스의 손실 없이 코어를 회수하고, 온도와 압력을 실시간으로 기록하는 저류층 PCS(Pressure Core Sampler)를 개발하였으며, 제작된 시제품의 검증을 위한 성능실험을 수행하였다. 모든 성능평가를 통과한 시제품은 In-situ 물성자료의 취득은 물론이고 정확하고 신뢰성 있는 시추코어를 확보하는 데 기여할 것이다.

Overview of Benign and Malignant Prostatic Disease in Pakistani Patients: A Clinical and Histopathological Perspective

  • Arshad, Huma;Ahmad, Zubair
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.3005-3010
    • /
    • 2013
  • Background: To present the overall clinical and histological perspective of benign and malignant prostatic disease as seen in our practice in the Section of Histopathology, Department of Pathology and Microbiology, Aga Khan University Hospital, Karachi, Pakistan. Materials and Methods: All consecutive prostate specimens (transurethral resection or TUR, enucleation, needle biopsies) received between July 1, 2012 and December 31, 2012 were included in the study. Results: Of the total of 785 cases, 621 (79.1%) were TUR specimens, 80 (10.2%) enucleation specimens, and 84 (10.7%) needle biopsies. Some 595 (75.8%) were benign, while 190 (24.2%) were malignant. Mean weight of BPH specimens was 19 grams and 43 grams for TUR and enucleation specimens respectively. Almost 67% of adenocarcinomas were detected on TUR or enucleation specimens. Of the above cases, 41.7% were clinically benign while 58.3% were clinically malignant. The average volume of carcinoma in all cases ranged between 60 to 65%. The average number of cores involved in needle biopsies was 5. In general, higher Gleason scores were seen in TUR/enucleation specimens than in needle biopsies. Overall, in all types of specimens, commonest Gleason score was 7, seen in 74 (38.9%) cases, followed by Gleason score 9 seen in 47 (24.7%) cases. Out of the 63 needle biopsies with carcinoma, radical prostatectomy was performed in 16 cases (25.4%). Conclusions: Benign prostatic hyperplasia (BPH) is extremely common and constitutes the bulk of prostate specimens. TMajority of prostatic carcinomas are still diagnosed on TUR or enucleation specimens. These included both clinically benign and clinically malignant cases. The volume of carcinoma in these specimens was quite high indicating extensive disease. Gleason scores were also generally high compared with scores from needle biopsies. Commonest Gleason score in all type of specimens was 7. Pathologic staging was possible in very few cases since radical prostatectomies are rarely performed.

지대치 코어 재료와 In-Ceram coping의 두께가 In-Ceram의 색에 미치는 영향 (COLOR DIFFERNCE OF IN-CERAM BY THE VARIOUS POSTCORE MATERIALS AND COPING THICKNESS)

  • 심직현;방몽숙
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.634-644
    • /
    • 1995
  • The purpose of this study is to evaluate the color differences in the In-Ceram according to coping thickness and various abutment core materials ; amalgam, precious alloy, composite resin, non-precious alloy. After the porcelain was built up on the In-Ceram coping at the thicknes of 0.3mm and 0.5mm then it was cemented with glass ionomer cement to the post & core materials. The following results were obtained. 1. There were significant differences in the $L^*$ values $a^*$ and $b^*$ values in the cementation of different cores, to the In-Ceram(P<0.01). $L^*$ values were not significantly different between the composite resin to the In-Ceram and the $a^*\;b^*$ values were not significantly different between the amalgam and the non-precious alloy. 2. All of cementations of In-Ceram to the core materisal had color difference(${\Delta}E^*ab$) compared to the In-Ceram. In the 0.3mm thickness of the In-Ceram copping non-precious alloy indicated the greatest value, while the composite resin core showed the lowest value with a thickness of 0.5mm In-Ceram copping. 3. By controlloing the In-Ceram coping thickness $L^*$ value was significatly different(P<0.01), but not in $a^*$ and $b^*$ values. 4. In an amalgam, precious & non-prcious alloys there was a 1,74 to 3.06 range color difference in the controlled thickness of In-Ceram coping at the thickness of 0.3mm and 0.5mm. The above results suggest that the requirement of the sufficient thickness of In-Ceram coping and the suitable core material in order to get an estheti restoration by In-Ceram and also to intercept the original core color.

  • PDF

고용량 광 디스크의 고속 재생을 위한 병렬 데이터 추출구조 (Parallel Data Extraction Architecture for High-speed Playback of High-density Optical Disc)

  • 최광석
    • 한국멀티미디어학회논문지
    • /
    • 제12권3호
    • /
    • pp.329-334
    • /
    • 2009
  • 광 디스크를 재생하려면 광 신호를 아날로그 전기신호로 변환하는 광 픽업을 거치고 난 뒤 신호 간 간섭을 없애기 위해 아날로그적으로 등화를 하고, 등화된 아날로그 신호를 AD 변환하여 디지털적으로 동기화된 데이터와 클록을 추출해야 한다. BD와 같은 고용량의 광 디스크를 저속으로 재생하여 동기화된 데이터와 클록을 추출하는데 었어서 추출 데이터 BER을 최소화하는 알고리즘은 다양하게 개발되어 적용되고 있다. 그러나 고용량의 광 디스크를 고속으로 재생 할 때 저속에서 적용된 알고리즘을 동일한 혼성 데이터 PLL과 PRML 하드웨어 구조에 적용하려면 800MHz 이상의 신호 처리가 이루어져야 한다. 일반적으로 사용되는 0.13-${\mu}m$ CMOS 공정에서 기존 방식의 구조를 가지고 800MHz의 이상의 신호처리를 위해서는 고속으로 동작해야하는 아날로그 코어 등이 필요하고 많은 시간과 노력의 레이아웃이 수반되어야 하는 등의 문제점이 제기된다. 본 논문에서는 고용량 광 디스크의 최고 배속인 BD 8x까지 동작 가능한 데이터 및 클록 추출 회로로서 병렬 데이터 PLL 및 PRML 구조를 제안하였다. 제안한 구조를 가지고 실험한 결과 BD 8x 에 해당하는 속도에서 오류 없이 동작함을 확인하였다.

  • PDF