• Title/Summary/Keyword: Coregistration

Search Result 20, Processing Time 0.034 seconds

Comparison of Visual- and Automatic Coregistration with MR Template based ROI Methods for Measurement of Specific Striatal Binding Ratio (SBR) in I-123 IPT SPECT

  • 주라형;서태석;최보영;이형구;김재승;문대혁
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.107-107
    • /
    • 2002
  • 목적: I-123 IPT SPECT에서 striatum에 ROI를 설정하여 Strial Binding Ratio를 측정하기 위해 사용되는 육안적인 방법과 MR Template based Coregistration 방법을 비교 평가하였다. 대상 및 방법: 파킨슨씨병 환자(IPD) 15명(남/녀:8/7, 63.3$\pm$4.8세)과 정상인 8명(남/녀:2/6, 61.4$\pm$16.5세) 에서 I-123 IPT(259MBq)를 주사한 후 2시간에 SPECT 영상을 얻었고 미상핵과 조가비핵의 전, 후부 및 후두엽에 각각 육안적인 방법과 MR Template based Coregistration방법으로 ROI를 설정하였다. MR Template based Coregistration 방법은 MNI TIMR template을 이용하여 SPECT영상을 voxel based intensity matching 방법으로 coregistration한 후midthalamic level에서 striatum의 경계를 따라 설정된 ROI를 이용하였다. 육안적인 방법은 striatal uptake가 가장 높은 level에서 3개의 ROI template를 striatum에 위치하였다. 두 방법으로 SBR과 nnterior/posterior ratio of SBR(APR)를 측정하였고 정상인과 파킨슨씨병 환자에서 두 방법을 비교하였다.

  • PDF

GEOMETRIC COREGISTRATION FOR TERRASAR-X INTERFEROMETRY

  • Yoon, Geun-Won;Kim, Sang-Wan;Lee, Yong-Woong;Won, loong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.251-254
    • /
    • 2008
  • The German radar satellite TerraSAR was launched in 2007. In this study, interferogram is generated using TerraSAR-X data and DEM (Digital Elevation Model). Coregistration procedures used with SAR images (i.e. master and slave) in traditional method results in serious errors for high resolution TerraSARX data because of the mutual shift of the master and slave images due to topography. This error becomes more serious in mountainous areas in which the coherence between interferometric pairs is relatively low. Here we processed a geometric coregistration with DEM exploiting height information. Through the method, interferometry processing is fulfilled to generate a qualified interferogram and coherence is improved. This approach will help high resolution X-band SAR interferometry in mountainous area.

  • PDF

Coregistration of QuickBird Imagery and Digital Map Using a Modified ICP Algorithm (수정된 ICP알고리즘을 이용한 수치지도와 QuickBird 영상의 보정)

  • Han, Dong-Yeob;Eo, Yang-Dam;Kim, Yong-Hyun;Lee, Kwang-Jae;Kim, Youn-Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.6
    • /
    • pp.621-626
    • /
    • 2010
  • For geometric correction of high-resolution images, the authors matched corresponding objects between a large-scale digital map and a QuickBird image to obtain the coefficients of the first order polynomial. Proximity corrections were performed, using the Boolean operation, to perform automated matching accurately. The modified iterative closest point (ICP) algorithm was used between the point data of the surface linear objects and the point data of the edge objects of the image to determine accurate transformation coefficients. As a result of the automated geometric correction for the study site, an accuracy of 1.207 root mean square error (RMSE) per pixel was obtained.

A Study on the 3D Coregistration of FDG Brain PET and MRI (FDG 뇌 PET영상과 MRI의 3차원적 합성에 관한 연구)

  • Lee, J.S.;Kwark, C.;Park, K.S.;Lee, D.S.;Chung, J.K.;Lee, M.C.;Koh, C.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.310-313
    • /
    • 1996
  • In this study, we developed three dimensional FDG brain PET and MRI coregistration technique. The boundaries of the head in PET and MRI were segmented using sinogram of emission PET scan and T1-weighted MRI. We registered both boundaries by minimizing the mean Euclidean distance of those. To display the registered PET and MRI simultaneously, we used weighted normalization method and interleaving method.

  • PDF

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

SAR 영상을 이용한 수치표고모형 제작방법에 관한 연구

  • 이창원;문우일
    • Proceedings of the KSRS Conference
    • /
    • 2000.04a
    • /
    • pp.85-90
    • /
    • 2000
  • 백두산 지역의 JERS-1 SLC 영상과 볼리비아 지역의 RADARSAT 영상에 대해 각각 interferometry와 radargrammetry를 이용하여 수치표고모형을 제작하였다. Interferometry 는 coregistration, interferogram 작성, phase unwrapping 과정으로 나눠지는데 temporal decorrelation으로 낮은 coherence, 부정확한 궤도정보가 DEM의 정확도를 저하시키는 주요 원인으로 작용하였다. Radargrammetry는 photogrammetry와 동일한 처리과정, 즉 GCP를 이용한 stereo model 설정, 영상 matching, 고도추출단계로 이루어지지만 광학영상 과는 다른 SAR 영상의 기하학적, 방사적 특성이 고려되어야 한다.

  • PDF

3D GIS Modelling Using Airborne Integrated Rapid Mapping System (AIR-MS(Airborne Integrated Rapid Mapping System)를 이용한 3D GIS 모델링)

  • Sohn, Hong-Gyoo;Yun, Kong-Hyun;Kim, Gi-Tae;Seo, Il-Hong
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.123-128
    • /
    • 2004
  • 최근 디지털 카메라(Digital camera), 다중/고분광 영상(Mumltispectral/Hyperspectral image), LiDAR(Light Detection and Ranging), InSAR(Interferometric SAR)와 같이 지상을 보다 상세하고 높은 정확도로 지상을 매핑할 수 있는 센서들이 출현하고 있다. 이러한 다양한 정보 취득 자료를 충분히 활용하여 통합하기 위해서는 영상에 대하여 정확한 기하보정 또는 정사영상의 제작과 LiDAR 자료와 같은 경우 평면위치의 오차를 조정하여 다중자료들 간의 정확한 지형보정(Coregistration)이 필요하다. 본 연구에서는 AIR-MS 자료를 이용하여 즉, 항공기로부터 취득한 LiDAR(Height와 강도(Intensity) 자료), digital camera을 통합하고, 기존의 컬러항공사진 및 1:1000 수치지도를 이용하여 3D GIS 자료의 생성을 시도하였다.

  • PDF

Motion Artifact Reduction Algorithm for Interleaved MRI using Fully Data Adaptive Moving Least Squares Approximation Algorithm (완전 데이터 적응형 MLS 근사 알고리즘을 이용한 Interleaved MRI의 움직임 보정 알고리즘)

  • Nam, Haewon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.28-34
    • /
    • 2020
  • In this paper, we introduce motion artifact reduction algorithm for interleaved MRI using an advanced 3D approximation algorithm. The motion artifact framework of this paper is data corrected by post-processing with a new 3-D approximation algorithm which uses data structure for each voxel. In this study, we simulate and evaluate our algorithm using Shepp-Logan phantom and T1-MRI template for both scattered dataset and uniform dataset. We generated motion artifact using random generated motion parameters for the interleaved MRI. In simulation, we use image coregistration by SPM12 (https://www.fil.ion.ucl.ac.uk/spm/) to estimate the motion parameters. The motion artifact correction is done with using full dataset with estimated motion parameters, as well as use only one half of the full data which is the case when the half volume is corrupted by severe movement. We evaluate using numerical metrics and visualize error images.

Investigation of Applications Technology for High Resolution SAR Images (고해상도 SAR 영상의 활용기술 동향분석)

  • Yoon, Geun-Won;Koh, Jin-Woo;Lee, Yong-Woong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.105-113
    • /
    • 2010
  • SAR(Synthetic Aperture Radar) has characteristics well-suited for the measurement of geophysical parameters during day and night in all weather conditions. Recently, SAR data with high resolution acquired by satellites became available to the public. In such data, many features and phenomena of geometric structure of man-made objects and natural environments become observable. In this paper, we discuss main considerations including geometric distortion and coregistration for efficient utilization of high resolution SAR images. And, various advanced technologies in SAR application fields are introduced.