• Title/Summary/Keyword: Core-A

Search Result 17,129, Processing Time 0.05 seconds

The Study on Intensity Index of Core Competency and Evaluation of Maturity Index of IT Outsourcing (기업의 핵심역량 집중도와 IT 아웃소싱 성숙도 평가에 관한 연구)

  • Lee, Hak-Sun;Kim, Jung-Po;Oh, Sung-Ho;Nam, Ki-Chan
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.2
    • /
    • pp.45-61
    • /
    • 2005
  • Recently, increasing attention has been paid to IT outsourcing and core competency of the corporation. Many companies are expected to focus on core competency rather than reduce IT cost from IT Outsourcing. But, by this time there are no a framework for evaluating intensity of core competency and maturity of IT outsourcing capability. This paper is conducted to provide a framework for evaluating intensity of core competency and maturity of IT outsourcing capability. This paper is to verify if the company's core competency and IT outsourcing capability have a significant influence on each other.

  • PDF

Comparison Between Direct- and Indirect-Cooling Core Catchers (직접냉각방식 및 간접냉각방식 Core Catcher의 성능비교)

  • Suh, Jung-Soo;Lee, Jong-Ho;Bae, Byung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.1043-1047
    • /
    • 2012
  • The European nuclear design requirements, which should be satisfied by nuclear reactors in Europe, usually recommend a so-called core catcher, which is a molten core ex-vessel cooling facility, to manage a severe accident at a nuclear reactor. Two different types of core catcher concepts are compared to determine their abilities to manage severe accidents and cool core melts. The study reveals that direct cooling is better for cooling capacity and is convenient to construct, while indirect cooing is better for the management of a severe accident.

Development of a Core Set of Korean Soybean Landraces [Glycine max(L.) Merr.]

  • Cho, Gyu-Taek;Yoon, Mun-Sup;Lee, Jeong-Ran;Baek, Hyung-Jin;Kang, Jung-Hoon;Kim, Tae-San;Paek, Nam-Chon
    • Journal of Crop Science and Biotechnology
    • /
    • v.11 no.3
    • /
    • pp.157-162
    • /
    • 2008
  • A total of 2,765 accessions were used as the initial set having both seed coat color and 100-seed weight data. As a result of molecular profiling using six SSR markers followed by stratification based on their usages, 335 accessions(12.1%) were selected by clustering based on UPGMA. Since 75 out of 335 accessions were mixed in phenotypic traits as a result of characterization, 260 accessions were finally set as a core set. This core set revealed nearly the same diversity compared with the other results on morphological traits of Korean soybean landraces. In total, 115 alleles(19.2 alleles per locus) were detected in the initial set and 79 alleles(13.2 alleles per locus) were detected in the core set. All 30 major alleles were present in the initial set and in the core set as well. In allele coverage, the core set was 71.4% of the initial set. These comparisons of number of alleles, gene diversity and coverage indicated that the core set represented the entire set well.

  • PDF

Fully CMOS-compatible Process Integration of Thin film Inductor with a Sputtered Bottom NiFe Core (스퍼터링 방법으로 증착된 하층 NiFe 코어를 갖는 박막인덕터의 CMOS 집적화 공정)

  • 박일용;김상기;구진근;노태문;이대우;김종대
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.138-143
    • /
    • 2003
  • A double spiral thin-film inductor with a NiFe magnetic core is integrated with DC-DC converter IC. The NiFe core is deposited on a polyimide film as the thinckness of NiFe is 2.5~3.5 ${\mu}$m. Then, copper conductor line is deposited on the NiFe core with double spiral structure. Process integration is performed by sequential processes of etching the polyimide film deposited both top and bottom of the NiFe core and electroplation copper conductor line from exposed metal pad of the DC-DC converter IC. Process integration is simplified by elimination planarization process for top core because the proposed thin-film inductor has a bottom NiFe core only. Inductor of the fabricated monolithic DC-DC converter IC is 0.53 ${\mu}$H when the area of converter IC and thin-film inductor are 5X5$\textrm{mm}^2$ and 3.5X2.5$\textrm{mm}^2$, respectively. The efficiency is 72% when input voltage and output voltage are 3.5 V and 6 V, respectively at the operation frequency of 8 MHz.

Finite Element Analysis of the Effects of Process and Material Parameters on the LVDT Output Characteristics (LVDT의 출력 특성에 미치는 공정 및 재료 변수의 영향에 관한 유한요소해석)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.11-19
    • /
    • 2021
  • Linear variable differential transformer (LVDT) is a displacement sensor and is commonly used owing to its wide measurement range, excellent linearity, high sensitivity, and precision. To improve the output characteristics of LVDT, a few studies have been conducted to analyze the output using a theoretical method or a finite element method. However, the material properties of the core and the electromagnetic force acting on the core were not considered in the previous studies. In this study, a finite element analysis model was proposed considering the characteristics of the LVDT composed of coils, core, magnetic shell and electric circuit, and the core displacement. Using the proposed model, changes in sensitivity and linear region of LVDT according to changes in process and material parameters were analyzed. The outputs of the LVDT model were compared with those of the theoretical analysis, and then, the proposed analysis model was validated. When the electrical conductivity of the core was high and the relative magnetic permeability was low, the decrease in sensitivity was large. Additionally, an increase in the frequency of the power led to further decrease in sensitivity. The electromagnetic force applied on the core increased as the voltage increased, the frequency decreased, and the core displacement increased.

The Effects of Core Stability Exercise on the Ability of Postural Control in Patients With Hemiplegia

  • Kim, Young-Dong;Hwang, Byoung-Yong
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.23-30
    • /
    • 2009
  • Core stability exercises for patients with hemiplegia have become increasingly important and a variety of exercises have been developed over the years to give the hemiplegic patients more stable postural control. This study examined the therapeutic effects of the core stability exercises on the ability of static and dynamic postural control. Fifteen hemiplegic patients (7 males, 8 females, age ranging from 46 to 76 years) hospitalized in a Daejoen rehabilitation hospital were enrolled in this study. Nine and 6 patients had a cerebral infarction and cerebral hemorrhage, respectively. The subjects participated in a core stability exercise program consisting of a total of 12 sessions 3 times each week over a 4-week period with each exercise lasting approximately 15 minutes. The ability of static and dynamic postural control by Berg Balance Scale (BBS) and Timed Up and Go (TUG), respectively, were measured before and after the core stability exercise. A Wilcoxon signed ranks test was used to compare the effects of the ability of static and dynamic postural control before and after core stability exercise in patients with hemiplegia. The ${\alpha}$=.05 level of significance was used for the statistical tests. Core stability exercises were effective in improving the ability of static postural control; BBS (p<.05). Core stability exercises were also effective in improving the ability of dynamic postural control; TUG (p<.05). Overall, core stability exercise is believed to be an important therapeutic method in rehabilitation programs for hemiplegic patients.

  • PDF

Effects of Core Stability Exercise on Strength, Activation of Trunk Muscles and Pulmonary Function in a Guillain-Barre Syndrome Patient: Case Report (코어 안정화 운동이 길랭바래증후군 환자의 몸통 근력, 근활성도 및 폐기능에 미치는 영향: 증례보고)

  • Eum, Young-Bae;Yoo, Kyung-Tae;Lee, Yun-Hwan;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.1
    • /
    • pp.111-121
    • /
    • 2021
  • PURPOSE: This study examined the effects of core stability exercise on the strength, activation of the trunk muscle, and pulmonary function in a Guillain-Barre syndrome (GBS) patient. METHODS: A 38-year-old male with GBS was enrolled in the study. A core stability exercise program was implemented for four weeks with a duration of 30 min/day and a frequency of three days/week. The program consisted of abdominal crunch, Swiss ball crunch, bicycle crunch, medicine ball sit-up with a toss, medicine ball rotational chest pass, raised upper body and lower body, and dead bug. Measurements of the strength of the trunk muscle (trunk flexion and hip flexion), activation of trunk muscles (rectus femoris; RA, external oblique abdominal; EOA, internal oblique abdominal; IOA, erector spinae; ES), and pulmonary function (forced expiratory capacity; FVC, forced expiratory volume at one second; FEV1) were taken before and after four weeks of core stability exercise. RESULTS: The strength of trunk muscles increased in the trunk and hip flexion after four weeks of core stability exercise, respectively, compared to the baseline levels. Activation of the trunk muscles increased in RA, EOA, and IOA after four weeks of core stability exercise compared to baseline levels, but decreased in ES after four weeks of core stability exercise compared to the baseline levels. The pulmonary function increased in FVC and FEV1 after four weeks of core stability exercise compared to the baseline levels. CONCLUSION: These results suggest that core stability exercise improves strength, Activation of the trunk muscle, And pulmonary function in patients with GBS.

A Modified Current Differential Relay for Transformer Protection (변압기 보호용 수정 전류차동 계전방식)

  • 강용철;김은수;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

Development of Transformation-Core for Magnetic Field in Switchgear

  • Gwan-hyung Kim
    • Journal of information and communication convergence engineering
    • /
    • v.21 no.4
    • /
    • pp.316-321
    • /
    • 2023
  • In this study, we developed a conversion core that produces power by utilizing the unused magnetic field in a switchboard. The conversion core makes it possible to utilize power that is normally wasted. The conversion core is composed of a core, filter, and battery. A prototype was installed in a switchboard to conduct tests on the output, battery storage, and output boosting of multiple batteries. Energy was harvested from the magnetic field generated by a busbar of the switchboard, and the power conversion ratio of the core yielded 1.08-1.01 mW per 1 A of bus current. Supplying this technology to the market after further R&D and commercialization is expected to greatly assist in the dissemination of energy harvesting, which has not yet spread widely to the general public.

Observation of Fracture Strengths According to the Core Materials for All Ceramic Bridge (전부도재교의치의 코어재료에 따른 파절강도 관찰)

  • Chung, In-Sung;Kim, Chi-Young
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.351-356
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the fracture strength between the core and veneering ceramic according to 2 core materials, In-Ceram Alumina and In-Ceram Zirconia, fabricated by electro ceramic layering technique. 2 different fixed partial denture cores of three units were veneered by veneering ceramic(Ceranion, Noritake) (n=10). Methods: The fracture strengths between the core and veneering ceramic were measured through the 3 point bending test. The interfaces between the core and veneering ceramic were observed with the X-ray dot mapping of EPMA. Results: The result of fracture strength was observed that IZP group, In-Ceram Zirconia core, had higher fracture strength. IPA group, In-Ceram Alumina core, had fracture strength of 359.9(${\pm}$86.2) N. IZP group, In-Ceram Zirconia core, had fracture strength of 823.2(${\pm}$243.0) N. X-ray dot mapping observation showed that a major element in the core and veneering ceramic of IPA group was alumina and silica, respectively. No binder was observed in interfaces between the core and veneering ceramic, and no ion diffusion or transition was observed between the core and veneering ceramic. However, apparent ion diffusion or transition was observed between the core and veneering ceramic of IZP group.