• Title/Summary/Keyword: Core saturation

Search Result 231, Processing Time 0.029 seconds

EMTP를 이용한 전자식 CT, PT의 시뮬레이션 특성 분석 (The Analysis for the Simulational Characteristics of the Electronic CT & PT using EMTP)

  • 신중은;김재철;송승엽;권영목;김언석;추동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.310-312
    • /
    • 2004
  • Generally, instrument transformer of the core type have been used for measuring current. Because instrument transformer has defects, electronic instrument was appeasred. This paper is introduced a basic concept and thoery of electronic instrument and described the the simulation of core type CT and no saturation CT. The evaluation of CT models implemented using EMTP(Electro Magnetic Transients Program) was carried out. The result of comparison both core type CT and no saturation CT are presented.

  • PDF

한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구 (A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train)

  • 이상우;김근웅;윤종학;한성수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

Development of Real-Time Internal Quality Evaluation Technique for Korean Red Ginseng using NIR Spectroscopy

  • Son, J.R.;Kim, G.;Kang, S.;Lee, K.J.
    • Agricultural and Biosystems Engineering
    • /
    • 제7권1호
    • /
    • pp.8-12
    • /
    • 2006
  • This study was conducted to develop a real-time internal quality evaluation technique for Korean red ginseng using NIR spectroscopy while they were moving to be graded. Internal qualities of Korean red ginseng were defined by color, amount of white core and cavity in the red ginseng. To evaluate the internal quality, PLS (Partial Least Square) model was developed. Spectrum saturation can be occurred when most red ginseng has a sound internal quality expressed by higher light transmittance ratio, but that could not found in the ginseng of internal white core under the same light situation. And, if spectrum saturation is obtained, it is hard to identify the exact information of internal quality. In order to evaluate of the internal quality regardless of having internal normal core or white core, an integral time controlled method was used to obtain traditional spectrum. This procedure was applied in real-time process when red ginseng was moving to be graded in the line. Among the 450 samples including 223 internal normal ginsengs and 227 internal white core ginsengs, 315 ginsengs (70%) were used to develop a calibration model and 135 ginsengs were spent to validate the model. The result of quality evaluation by the model was very good showing SEP and bias were 0.3573 and 0.0310, respectively, and the accuracy was 95.6%.

  • PDF

코어 비저항 측정에 미치는 영향요소에 대한 실험적 고찰 (Experimental Verification on Factors Affecting Core Resistivity Measurements)

  • 김영화;최예권
    • 지구물리
    • /
    • 제2권3호
    • /
    • pp.225-233
    • /
    • 1999
  • 암석의 비저항값은 암석 자체의 성질뿐만 아니라 유체의 종류, 온도, 물 포화율, 접촉상태, 유도분극, 측정기기 및 사용전원의 주파수 등, 여러 요인에 의하여 영향을 받는다. 이 연구는 암석의 비저항을 정확하고 정밀하게 측정하기 위한 기초 연구의 일환으로서, 비저항 실측자료를 비교 분석하는 과정을 통하여 비저항 측정에 영향을 주는 다양한 요소들을 추적하고, 아울러 비저항 측정에 있어서 최적의 환경 조건을 찾고자 하였다. 특히 온도, 물 포화율, 시료와 전극의 접촉상태, 측정 주파수의 영향 등이 종합적으로 분석되었으며, 전도성 접착제와 절연 테이핑 방법 그리고 시계열 비저항자료의 이용이 비저항 측정의 정확도와 정밀도 향상에 크게 기여할 수 있음을 보였다.

  • PDF

DVR의 특성을 고려한 매칭변압기의 자속포화 해석 (Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR))

  • 손진근;김동준;강민구;전희종
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

전기강판의 가공 및 포화를 고려한 IPM 모터의 철손 해석 (Core Loss Analysis of IPM Motor Considering Magnetic Saturation and Manufacturing of Electrical Steel)

  • 하경호;김지현;김재관;이선권;나민수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.887.1_888.1
    • /
    • 2009
  • This paper proposes a core loss analysis method to obtain high accuracy prediction by using Multi-curve representing magnetic properties of a electrical steel in Finite Element Analysis (FEA). Generally, the magnetic prosperities of the electrical steel are measured by Epstein Method based on the international standards that are not good sufficient to predict motor performances. The method only aims to grade products in steel companies The magnetic properties of actual stator core is highly different to those given by steel companies due to the fact that stacking effect, shearing stress, nature anisotropy of electrical steels are not taken into account. In this paper, the magnetic properties are variously measured by three measuring devices, and then the several BH curves and BW curves obtained are used to analyze the core loss of a IPM. The BH curve in the high magnetic field are extrapolated using the mathematical formulation with the maximum saturation magnetic polarization measured

  • PDF

Microstructure and Soft Magnetic Properties of Fe-6.5 wt.%Si Sheets Fabricated by Powder Hot Rolling

  • Kim, Myung Shin;Kwon, Do Hun;Hong, Won Sik;Kim, Hwi Jun
    • 한국분말재료학회지
    • /
    • 제24권2호
    • /
    • pp.122-127
    • /
    • 2017
  • Fe-6.5 wt.% Si alloys are widely known to have excellent soft magnetic properties such as high magnetic flux density, low coercivity, and low core loss at high frequency. In this work, disc-shaped preforms are prepared by spark plasma sintering at 1223 K after inert gas atomization of Fe-6.5 wt.% Si powders. Fe-6.5 wt.% Si sheets are rolled by a powder hot-rolling process without cracking, and their microstructure and soft magnetic properties are investigated. The microstructure and magnetic properties (saturation magnetization and core loss) of the hot-rolled Fe-6.5 wt.% Si sheets are examined by scanning electron microscopy, electron backscatter diffraction, vibration sample magnetometry, and AC B-H analysis. The Fe-6.5 wt.% Si sheet rolled at a total reduction ratio of 80% exhibits good soft magnetic properties such as a saturation magnetization of 1.74 T and core loss ($W_{5/1000}$) of 30.7 W/kg. This result is caused by an increase in the electrical resistivity resulting from an increased particle boundary density and the oxide layers between the primary particle boundaries.

LED-based illuminated V-core optical engine

  • Chen, Chin-Chung;Mo, Chi-Neng;Wu, Shih-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.560-563
    • /
    • 2006
  • LED is promising for the application of specialty illumination. Thiscolor management system, V-core, with LED light sources and the structure of V-core for LCoS projector has been proposed to improve the primary saturation, uniformity and contrast. We designed the high efficient LED modules for high brightness requirement. The LED module can operate in narrow-direction indicator, $12^{\circ}$.

  • PDF

내삽법 기반의 최소자승법을 이용한 개선된 CT 포화 복원 알고리즘 (An Enhanced Compensation Algorithm for the CT Saturation Using Interpolation-based LSQ(Least Square) Fitting Method)

  • 류기찬;강상희;이봉현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.14-15
    • /
    • 2006
  • A saturation of magnetic flux in the core may occur when a large primary current flows when the iron-cored current transformer is used. This saturation makes the distorted secondary current of the CT. the distorted secondary current may cause the mal-operation or operation time delay of protective relays. CT compensation algorithm using The LSQ(Least Square) fitting method has a problem. It needs to acquire enough data for executing this algorithm without an error. In this paper, an enhanced algorithm using interpolation based LSQ(Least Square) Fitting Method is proposed. The Lagrange Interpolation Method is used for the interpolation and CT is simulated by EMTP. The results show that the proposed algorithm can accurately compensate a distorted secondary current more than existing Algorithm when the saturation severely occurs.

  • PDF

철심 변류기의 2차 전류 보상 알고리즘의 실시간 구현 및 오차 분석 (Hardware implementation and error analysis of an algorithm for compensating the secondary current of iron-cored current transformers)

  • 강용철;김성수;박종근;강상희;김광호
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.490-500
    • /
    • 1996
  • The conventional method to deal with current transformer (CT) Saturation is over dimensioning of the core so that CTs can carry up to 20 times the rated current without exceeding 10% ratio correction. However, this not only reduces the sensitivity of relays as some errors may still be present in the secondary current when a severe fault occurs, but also increases the CT size. This paper presents an algorithm for compensating the distorted secondary current of iron-cored CTs under CT saturation using the magnetization (flux-current : .lambda.-i) curve and its performance is examined for fault currents encountered on a typical 345[kV] Korean transmission system, under a variety of different system and fault conditions. In addition, the results of hardware implementation of the algorithm using a TMS320C10 digital signal processor are also presented. The proposed algorithm can improve the sensitivity of relays to low level internal faults, maximize the stability of relays for external faults, and reduce the required CT core cross-section significantly. (author). refs., figs.