• 제목/요약/키워드: Core Makeup Tank

검색결과 9건 처리시간 0.023초

Numerical study on CMT boron replenishment strategy for an AP1000 nuclear power unit

  • Wang, Hong;Zhang, Miao;Li, Jialong;Wang, Junpeng
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2321-2328
    • /
    • 2022
  • The passive safety system is adopted in an AP1000 nuclear power unit to improve the operation safety of the whole unit. However, due to boron diffusion and periodic sampling, boron dilution occurs in the core makeup tank. The boron replenishment process in the core makeup tank is essential and becomes particularly important. Based on the validated models, this article numerically investigates the influence of the replenishment flow rate and the position on the boron distribution in the core makeup tank. The thermal fatigue phenomenon of the "T" connection caused by replenishment is analyzed. Finally, the replenishment strategy is proposed to benefit both boron mixing in the core makeup tank and eliminating the thermal fatigue of the "T" connection.

Development of a special thermal-hydraulic component model for the core makeup tank

  • Kim, Min Gi;Wisudhaputra, Adnan;Lee, Jong-Hyuk;Kim, Kyungdoo;Park, Hyun-Sik;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1890-1901
    • /
    • 2022
  • We have assessed the applicability of the thermal-hydraulic system analysis code, SPACE, to a small modular reactor called SMART. For the assessment, the experimental data from a scale-down integral-test facility, SMART-ITL, were used. It was conformed that the SPACE code unrealistically calculates the safety injection flow rate through the CMT and SIT during a small-break loss-of-coolant experiment. This unrealistic behavior was due to the overprediction of interfacial heat transfer at the steam-water interface in a vertically stratified flow in the tanks. In this study, a special thermal-hydraulic component model has been developed to realistically calculate the interfacial heat transfer when a strong non-equilibrium two-phase flow is formed in the CMT or SIT. Additionally, we developed a special heat structure model, which analytically calculates the heat transfer from the hot steam to the cold tank wall. The combination of two models for the tank are called the special component model. We assessed it using the SMART-ITL passive safety injection system (PSIS) test data. The results showed that the special component model well predicts the transient behaviors of the CMT and SIT.

피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구 (Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility)

  • 배황;이민규;류성욱;신수재;김영인;이성재;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.

복합안전주입탱크(Hybrid SIT) 설계개념 (Design Concept of Hybrid SIT)

  • 권태순;어동진;김기환
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.104-108
    • /
    • 2014
  • The recent Fukushima nuclear power plant accidents shows that the core make up at high RCS pressure condition is very important to prevent core melting. The core make up flow at high pressure condition should be driven by gravity force or passive forces because the AC-powered safety features are not available during a Station Black Out (SBO) accident. The reactor Coolant System (RCS) mass inventory is continuously decreased by releasing steam through the pressurizer safety valves after reactor trip during a SBO accident. The core will be melted down within 2~3 hours without core make up action by active or passive mode. In the new design concept of a Hybrid Safety Injection Tank (Hybrid SIT) both for low and high RCS pressure conditions, the low pressure nitrogen gas serves as a charging pressure for a LBLOCA injection mode, while the PZR high pressure steam provides an equalizing pressure for a high pressure injection mode such as a SBO accident. After the pressure equalizing process by battery driven initiation valve at a high pressure SBO condition, the Hybrid SIT injection water will be passively injected into the reactor downcomer by gravity head. The SBO simulation by MARS code show that the core makeup injection flow through the Hybrid SIT continued up to the SIT empty condition, and the core heatup is delayed as much.

SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구 (Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL)

  • 류성욱;배황;유효봉;변선준;김우식;신용철;이성재;박현식
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.165-172
    • /
    • 2016
  • 노심보충탱크(Core Makeup Tank, CMT), 안전주입탱크(SafetyInjection Tank, SIT)와 자동감압계통(Auto Depressurization System, ADS)로 구성된 1 계열의 SMART 피동안전주입계통의 주입특성을 파악하기 위한 소형냉각재상실사고(SBLOCA) 모의에 대한 실험적 연구가 수행되었다. SBLOCA의시험은 0.4 인치 안전주입수 배관파단에 대해 수행되었으며, 정상상태 조건은 실험요건서에 제시된 시험 초기 조건을 만족시키도록 746초 동안 운전되었다. 노심 출력 및 안전주입 유량 등의 경계 조건도 적절히 모의되었으며, 안전주입계통 배관에서의 파단, 히터 트립 및 잔열곡선 인가, 원자로냉각재펌프 관성서행(Coastdown), 급수 중단, CMT 및 SIT의 주입, ADS #1 개방이 SBLOCA 시나리오에 따라 적절히 모의되었다. 노심지지원통 내부의 액체환산수위는 파단 초반에 감소하다가 CMT와 SIT가 주입되면서 서서히 회복되었으며, 피동안전주입계통의 주입유량이 노심 수위를 회복하기에 충분한 것으로 판단할 수 있다.

SAFETY ANALYSIS OF INCREASE IN HEAT REMOVAL FROM REACTOR COOLANT SYSTEM WITH INADVERTENT OPERATION OF PASSIVE RESIDUAL HEAT REMOVAL AT NO-LOAD CONDITIONS

  • SHAO, GE;CAO, XUEWU
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.434-442
    • /
    • 2015
  • The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

Improvement of Direct Contact Condensation Model of RELAP5/MOD3.1 for Passive High-Pressure Injection System

  • Lee, Sang-Il;No, Hee-Cheon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.368-373
    • /
    • 1996
  • A simple set of the transition criterion of the condensation regimes and the heat transfer coefficients on the direct contact condensation of the core makeup tank is developed, and implemented in RELAP5/MOD3.1 The condensation regimes are divided into two regimes: supply limit and condensation limit. In mode]ing the transition criterion between two regimes, a large-eddy model developed by Theofanous is used, and the empirical coefficient of the present large-eddy model is close to that of the large-eddy model. It turns out that the modified code better predicts the experimental data, especially the injection flow rate and the water level trend than the original code does.

  • PDF

SMART-ITL 1 계열 피동안전계통을 이용한 유동분사기 성능에 대한 실험연구 (An Experimental Study on Flow Distributor Performance with Single-Train Passive Safety System of SMART-ITL)

  • 류성욱;배황;양진화;전병국;윤은구;김재민;방윤곤;김명준;이성재;박현식
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.124-132
    • /
    • 2016
  • 노심보충탱크 상부에 설치되는 유동분사기 형상에 따른 냉각수 주입특성 및 탱크 내에서의 열수력 현상 변화를 파악하기 위한 안전주입배관 2인치 파단 소형냉각재상실사고(SBLOCA) 모의시험이 잔열 및 피동잔열제거계통(PRHRS) 모의 없이 수행되었다. 두 가지 형상의 유동분사기를 설치하고 수행한 각각의 시험은 거의 유사한 초기 및 경계조건에서 수행되었으며, 이로 인해 반복시험에 대한 재현성이 충족되었다고 판단된다. 시험결과는 유동분사기의 종류(본 시험에서는 구멍의 개수에 해당)에 관계없이 유사한 열수력학적 거동을 보였으며, 초기 주입유량 관점에서는 구멍의 개수가 2배인 B형이 A형에 비해 좀 더 우수한 주입 성능을 보였다. 노심보충탱크 격리 밸브가 개방된 후 압력평형배관을 통해 유입되는 고온의 원자로냉각재는 상부 헤더에서 상대적으로 저온인 $50^{\circ}C$ 물과 혼합되면서 증기 응축과 같은 상변화에 의한 압력 변동을 동반하는 다차원 열유동 현상을 일으키게 된다. 이로 인해 초반부 노심보충탱크 주입 유량은 상온운전 조건에서 보다는 작게 되고, 일정시간 경과 후에는 유사한 주입유량 특성을 보였다.