• 제목/요약/키워드: Core Correction

검색결과 158건 처리시간 0.033초

Ebstein`s 심기형의 개심수술 8예 (Open Heart Correction Of Ebstein`S Anomaly: A Report Of 8 Cases)

  • 김삼현
    • Journal of Chest Surgery
    • /
    • 제14권4호
    • /
    • pp.388-398
    • /
    • 1981
  • Fourteen Infants with congenital cardiac anomalies underwent primary surgical Intervention within the first 12 months of life. There were eight patients with ventricular septal defect, two with total anomalous pulmonary venous return [TAPVR], and the remainders with tetralogy of Fallot, transposition of great arteries [d-TGA], Taussing-Bing malformation, and coronary A-V fistula. The age of the patients ranged from 5 to 12 months, with a mean age of 9.9 months. The mean weight was 6.7 Kg [3.8 to 9.5 KS]. Congestive heart failure persisting despite intensive medical treatment was present In 8 patients [56%], and was the most common indication for operation. Early operation was necessary in 5 of these patients [35%], because of failure to thrive and recurrent pulmonary infection. In one patient with TOF, frequent hypoxic spell prompted the necessity for early operation. In cases of VSD, TAP. VR, TOF, and coronary A-V fistula, Intracardiac repair was done with conventional cardiopulmonary bypass, chemical cold cardioplegia, and topical myocardial cooling. Deep hypothermic circulatory arrest with surface induced cooling, followed by core cooling and core rewarming, was employed .for better exposure in the cases of d-TGA and Taussing-Bing malformation. The results were however, not satisfactory. The overall mortality was 28 per cent. There were no deaths in the eight patients with VSD. The one with coronary A-V fistula survived. The other 5 cases all expired either on the table or immediately after operation. The non-fatal post-operative complications included low cardiac output, respiratory insufficiency, bleeding, and temporary A-V block. The causes of death were prolonged circulatory arrest time in d-TGA, complete A-V block and low cardiac output in TOF and Taussing-Bing malformation and prolonged bypass time and Inadequate correction in TAPVR.

  • PDF

GIS 스페이서 내장형 저전력 측정용 변압기의 설계 및 제작 (Design and Fabrication of an LPVT Embedded in a GIS Spacer)

  • 박성관;이경렬;김남훈;김철환;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.175-181
    • /
    • 2024
  • In electrical power substations, bulky iron-core potential transformers (PTs) are installed in a tank of gas-insulated switchgear (GIS) to measure system voltages. This paper proposed a low-power voltage transformer (LPVT) that can replace the conventional iron-core PTs in response to the demand for the digitalization of substations. The prototype LPVT consists of a capacitive voltage divider (CVD) which is embedded in a spacer and an impedance matching circuit using passive components. The CVD was fabricated with a flexible PCB to acquire enough insulation performance and withstand vibration and shock during operation. The performance of the LPVT was evaluated at 80%, 100%, and 120% of the rated voltage (38.1 kV) according to IEC 61869-11. An accuracy correction algorithm based on LabVIEW was applied to correct the voltage ratio and phase error. The corrected voltage ratio and phase error were +0.134% and +0.079 min., respectively, which satisfies the accuracy CL 0.2. In addition, the voltage ratio of LPVT was analyzed in ranges of -40~+40℃, and a temperature correction coefficient was applied to maintain the accuracy CL 0.2. By applying the LPVT proposed in this paper to the same rating GIS, it can be reduced the length per GIS bay by 11%, and the amount of SF6 by 5~7%.

편평족 중학생의 고관절 교정 운동 프로그램과 발교정구 착용 유무가 안정시 종골 기립 각도, 발목의 가동범위, 코어 근력에 미치는 영향 (The Effects of Corrective Hip Joint Exercises and Foot Orthotics on RCSP, Ankle's Range of Motion, and Core Muscle Strength for Middle School Students with Pes Planus)

  • 김남희;이경옥
    • 한국운동역학회지
    • /
    • 제25권4호
    • /
    • pp.401-412
    • /
    • 2015
  • Objective : The purpose of this study is to evaluate the effects of hip joint exercises and orthotics on RCSP, ankle's range of motion, and core muscle strength of middle school students with pes planus. Method : Out of the original pool of 200 students, 60 students with pes planus (RCSP < -2) were selected for the study. The selected 60 students were then divided into four groups. The first group was a combined orthotics and exercise group (12 students), the second was the orthotics-only group (9 students), the third was the exercise-only group (8 students), and the last was the control group (10 students). Exercise groups worked out twice a week for 60 minutes per session over 8 weeks. The independent variables were corrective hip joint exercises and orthotics. The dependant variables consisted of kinematic and kinetic variables. The kinematic variables were RCSP, and ankle's range of motion (dorsiflexion and plantarflexion). The kinetic variables were muscles forces that consist in core muscle strength, which are hip joint adduction, abduction, and flexion muscles forces. Statistical analysis was performed via SPSS 18.0 with multivariate analysis of covariance (MANCOVA) and a paired t-test was used. Results : The left foot was more responsive to the treatments, both exercise and orthotics, than the right foot. RCSP improved significantly in the left foot for the first and third groups. Only the first group significantly improved hip joint adduction, abduction, and flexion muscles' strengths. As for the ankle's range of motion of the left foot, plantarflexion showed improvement when treated with exercise, orthotics, or both. Conclusion : This study found that exercise is more effective in correcting RCSP and foot orthotics is more effective in reinforcing core muscle strength. Future studies should expand on these results to examine the relationship between the ankle, hip, and pelvis.

상하부 2개의 노외계측기를 이용한 축방향 출력분포 감시계통 개발 (Development of Axial Power Distribution Monitoring System Using Two-Level Encore Detector)

  • Chi, Sung-Goo;Song, Jae-Woong;Ahn, Dwak-Hwan;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.294-301
    • /
    • 1989
  • 상하부 2개의 노외계측기, 노입구관 온도 및 제어봉 위치 신호를 이용하여 상세한 축방향 출력분포를 계산할 수 있는 APDMS프로그램을 개발하였다. 상하부 2개의 노외계측기 신호가 제어봉 위치에 의하여 결정된 제어봉 간섭계수와 노입구관 온도에 따른 온도 간섭계수에 대하여 보정된 후 노심 주변출력을 얻기 위하여 보정된 노외계측기 신호에 shape annealing matrix가 적용되었다. 노심의 상하부 경계에서의 출력을 얻기 위해서는 평균 노심출력과 주변출력과의 선형적 관계를 이용한 노심 상하부의 평균출력에 경계점 출력보정계수가 적용되었다. 축방향 출력분포가 2개의 노외계측기에 의해 계산된 상하부 평균 노심출력, 상하부 경계면에서의 출력 및 미리 계산된 노심의 중심 위치에서의 출력을 이용하여 spline approximation에 의하여 계산되었다. 연소도, 출력준위, 제어봉 위치 및 axial offset의 변화에도 불구하고 고리 3호기 4주기에 대하여 BOXER 코드와 APDMS 프로그램에 의해 계산된 축방향 출력분포의 비교는 5% root mean square 오차내에서 일치함을 보여 주었다.

  • PDF

Genome-wide Response of Normal WI-38 Human Fibroblast Cells to 1,763 MHz Radiofrequency Radiation

  • Im, Chang-Nim;Kim, Eun-Hye;Park, Ae-Kyung;Park, Woong-Yang
    • Genomics & Informatics
    • /
    • 제8권1호
    • /
    • pp.28-33
    • /
    • 2010
  • Increased exposure of human to RF fields has raised concerns for its potential adverse effects on our health. To address the biological effects of RF radiation, we used genome wide gene expression as the indicator. We exposed normal WI-38 human fibroblast cells to 1763 MHz mobile phone RF radiation at a specific absorption rate (SAR) of 60 W/kg with an operating cooling system for 24 h. There were no alterations in cell numbers or morphology after RF exposure. Through microarray analysis, we identified no differentially expressed genes (DEGs) at the 0.05 significance level after controlling for multiple testing errors with the Benjaminiochberg false discovery rate (BH FDR) method. Meanwhile, 82 genes were differentially expressed between RF-exposed cells and controls when the significance level was set at 0.01 without correction for multiple comparisons. We found that 24 genes (0.08% of the total genes examined) were changed by more than 1.5-fold on RF exposure. However, significant enrichment of any gene set or pathway was not observed from the functional annotation analysis. From these results, we did not find any evidence that non-thermal RF radiation at a 60-W/kg SAR significantly affects cell proliferation or gene expression in WI-38 cells.

콘크리트의 형상비 및 온도변화에 따른 부착강도 특성평가 (Evaluation of Bond Strength Properties with Changing the Aspect Ratio and Temperature of Concrete)

  • 김현석;정원경;오한진;박준영;김형배
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.19-26
    • /
    • 2018
  • PURPOSES : The main purpose of this study is suggest of field bond strength evaluation method for more objective evaluation method through Evaluation of Bond Strength Properties with changing aspect ratio and temperature. METHODS : The evaluation is laboratory bond strength test. Using the core machine, the pull-off test method ; the bond strength test of interface layer the universal testing machine. RESULTS : As a result of the laboratory bond strength evaluation, it was verified that the bond strength by aspect ratio decreases linearly with increasing aspect ratio and the bond strength properties by temperature change existed at high and low temperature condition relative to odinary temperature condition. CONCLUSIONS : According to the results of laboratory bond strength evaluation, the field bond strength evaluation results suggest applying the proposed correction factor (0.8, 1.0, 1.4, 1.9) according to aspect ratio(0.5, 0.1, 1.5, 2.0), For more objective evaluation of the bond strength, it is analyzed that the evaluation value is within $6{\sim}32^{\circ}C$ and the result can be obtained within 5% of the coefficient of variation.

Improvement and application of DeCART/MUSAD for uncertainty analysis of HTGR neutronic parameters

  • Han, Tae Young;Lee, Hyun Chul;Cho, Jin Young;Jo, Chang Keun
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.461-468
    • /
    • 2020
  • The improvements of the DeCART/MUSAD code system for uncertainty analysis of HTGR neutronic parameters are presented in this paper. The function for quantifying an uncertainty of critical-spectrumweighted few group cross section was implemented using the generalized adjoint B1 equation solver. Though the changes between the infinite and critical spectra cause a considerable difference in the contribution by the graphite scattering cross section, it does not significantly affect the total uncertainty. To reduce the number of iterations of the generalized adjoint transport equation solver, the generalized adjoint B1 solution was used as the initial value for it and the number of iterations decreased to 50%. To reflect the implicit uncertainty, the correction factor was derived with the resonance integral. Moreover, an additional correction factor for the double heterogeneity was derived with the effective cross section of the DH region and it reduces the difference from the complete uncertainty. The code system was examined with the MHTGR-350 Ex.II-2 3D core benchmark. The keff uncertainty for Ex.II-2a with only the fresh fuel block was similar to that of the block and the uncertainty for Ex.II-2b with the fresh fuel and the burnt fuel blocks was smaller than that of the fresh fuel block.

A Lattice-Based Monte Carlo Evaluation of Canada Deuterium Uranium-6 Safety Parameters

  • Kim, Yonghee;Hartanto, Donny;Kim, Woosong
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.642-649
    • /
    • 2016
  • Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANada Deuterium Uranium (CANDU-6) reactor have been evaluated using the Monte Carlo method. For accurate analysis of the parameters, the Doppler broadening rejection correction scheme was implemented in the MCNPX code to account for the thermal motion of the heavy uranium-238 nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted using MCNPX. The FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated using several cross-section libraries such as ENDF/B-VI.8, ENDF/B-VII.0, JEFF-3.1.1, and JENDL-4.0. The PCR value is also evaluated at mid-burnup conditions to characterize the safety features of an equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, we considered a huge number of neutron histories in this work and the standard deviation of the k-infinity values is only 0.5-1 pcm.

역회복 전류억제 역률개선 회로 (Reverse Recovery Current Suppression Power Factor Correction Circuit)

  • 장덕규;신용희;김창선;박귀철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.942-943
    • /
    • 2008
  • The boost converter is usually used in power factor correction. The dynamic losses of its output diode are produced during the reverse recovery time. The power efficiency is decreased due to the losses and also it generates the noise. These disadvantages have been remarkably improved by ZCS and ZVS techniques of power factor improvement circuit. Some benefits lead to the achievement of higher power density and the development cost can be decreased. In this paper work, the reverse recovery suppression(RS) PFC method is used. A inductor and a diode are added into the conventional circuit. The switching device, MOSFET is turned off after the reverse recovery current has come to the zero level. The Zero Current Switching(ZCS) is implemented at that time. This power conversion technique improves the efficiency to about 1% and reduces the noise obviously. And the additional inductor can be designed using an original filter core in the circuit. The converter size is reduced effectively.

  • PDF

Improved Bridgeless Interleaved Boost PFC Rectifier with Optimized Magnetic Utilization and Reduced Sensing Noise

  • Cao, Guoen;Kim, Hee-Jun
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.815-826
    • /
    • 2014
  • An improved bridgeless interleaved boost power factor correction (PFC) rectifier to improve power efficiency and component utilization is proposed in this study. With combined conventional bridgeless PFC circuit and interleaved technology, the proposed rectifier consists of two interleaved and magnetic inter-coupling boost bridgeless converter cells. Each cell operates alternatively in the critical conduction mode, which can achieve the soft-switching characteristics of the switches and increase power capacity. Auxiliary blocking diodes are employed to eliminate undesired circulating loops and reduce current-sensing noise, which are among the serious drawbacks of a dual-boost PFC rectifier. Magnetic component utilization is improved by symmetrically coupling two inductors on a unique core, which can achieve independence from each other based on the auxiliary diodes. Through the interleaved approach, each switch can operate in the whole line cycle. A simple control scheme is employed in the circuit by using a conventional interleaved controller. The operation principle and theoretical analysis of the converter are presented. A 600 W experimental prototype is built to verify the theoretical analysis and feasibility of the proposed rectifier. System efficiency reaches 97.3% with low total harmonic distortion at full load.