• 제목/요약/키워드: Copper-selective electrode

검색결과 22건 처리시간 0.023초

Highly Copper(II)-selective PVC Membrane Based on a Schiff Base Complex of N,N'-Bis-pyridin-2-ylmethylene-naphthalene-1,8-diamine as an Ionophore

  • Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1593-1596
    • /
    • 2006
  • The polymeric membrane electrodes based on N,N'-bis-pyridin-2-ylmethylene-naphthalene-1,8-diamine as an ion carrier were prepared and tested for the copper-ion selective electrode. The membrane has a linear dynamic range between $10^{-6}$ and $10^{-2}$ M with a Nernstian slope of 29.6 mV per decade, and its detection limit was $10^{-5.62}$M. The potentiometric response is independent of the pH range of 3-5. The proposed electrode showed good selectivity and response for $Cu^{2+}$ over a wide variety of other metal ions in pH 4.0 buffer solutions.

Determination of Salicylate by Selective Poly(vinylchloride) Membrane Electrode Based on N,N'-1,4-Butylene Bis(3-methyl salicylidene iminato) Copper(II)

  • Mazloum Ardakani, M.;Jamshidpoor, M.;Naeimi, H.;Heidarnezhad, A.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권8호
    • /
    • pp.1127-1132
    • /
    • 2006
  • A new salicylate-selective electrode based on the complex N,N'-1,4-butylene bis(3-methyl salicylidene iminato) copper(II) as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 59.1 ${\pm}$ 1.0 mV/decade and a linear range of $1.0\;{\times}\;10^{-6}$-1.0 M for salicylate. The limit of detection was $5.0\;{\times}\;10^{-7}$ M. It has a fast response time 10 s and can be used for more than three months. The selective coefficients were determined by the fixed interference method (FIM) and could be used in the pH range 4.5-10.5. It was employed as an indicator electrode for direct determination of salicylate in pharmaceutical samples.

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권6호
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.

2,5-Dimercapto-1,3,4-thiadiazole에 의한 구리의 전위차 적정 정량 (Potentiometric Determination of Copper with 2,5-Dimercapto-1,3,4-thiadiazole)

  • 하영구
    • 대한화학회지
    • /
    • 제20권4호
    • /
    • pp.277-279
    • /
    • 1976
  • 은 전극을 지시전극으로 하고 표준칼로멜 전극을 기준전극으로 하여 전압플로위회로를 이용하여 수용액에서 2,5-dimercapto-1,3,4-thiadiazole에 의한 구리의 전위차 적정법을 연구하였다. 이 시약은 구리의 전위차 적정 정량에 뛰어나게 이용할 수 있었고 여러가지 가리움제를 사용하여 다른 이온들의 존재하에 대기중에서 미량의 구리를 직접 적정할 수 있었다.

  • PDF

Novel Copper(Ⅱ)-Selective Senor Based on a New Hexadentates Schiff's Base

  • Ganjali, Mohammad Reza;Emami, Mehdi;Salavati Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1394-1398
    • /
    • 2002
  • A novel copper(II) membrane electrode based on diphenylisocyanate bis(acetylacetone) ethylenediimine (DIBAE), as a new hexadentates Schiff's base was prepared. The electrode exhibited a Nernstian response for Cu$^{2+}$ ions over a wide concentration range (1.0 ${\times}$ 10$^{-1}$ to 1.0 ${\times}$ l0$^{-6}$ M) with a limit of detection of 6.0 ${\times}$ 10$^{-7}$ M (39 ppb). The sensor shows a fast response time (15s) and the membrane can be used for more than 4 months without observing any major deviation. The electrode revealed very good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor could be used in a pH range of 3.0-7.5. It was applied to the direct potentiometric determination of copper in black tea, and in wastewater of copper electroplating samples. The electrode was also used in potentiometric titration of the copper(II) ion with EDTA.

Nafion-DTPA-Glycerol이 수식된 유리탄소전극을 사용한 미분펄스 전압전류법에 의한 구리(II)이온의 측정 (Differential Pulse Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol)

  • 박찬주;박은희;정근호
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.115-122
    • /
    • 2004
  • A glassy carbon electrode(GCE) modified with nafion-DTPA (diethylene triamine-pentaacetic acid)-glycerol is used for the highly selective and sensitive determination of a trace amount of Cu(II). Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu(II), are optimized. The Copper(II) is accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface is characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry(DPV). The electrochemical response is evaluated with respect to concentration of modifier, pH and preconcentration time, quiet time, copper(II) concentration, and other variables. A linear range is obtained in the concentration range 1.0${\times}$10$^{-8}$ M-1.0${\times}$10$^{-6}$ MCu(II) with 7 min preconcentration time. The detection limit(3s) is as low as 2.36${\times}$10$^{-8}$ M (1.50 ppb).

Copper phthalocyanine conjugated PANI coated screen printed carbon electrode for electrochemical sensing of 4-NP

  • Ramalingam Manikandan;Jang-Hee Yoon;Seung-Cheol Chang
    • 한국표면공학회지
    • /
    • 제56권1호
    • /
    • pp.40-54
    • /
    • 2023
  • In this work, we synthesized a novel electrochemical sensing materials based on tetracarboxylic copper phthalocyanine (TcCuPtc) conjugated PANI (TcCuPtc@PANI). The synthesized materials were employed to modify the screen-printed carbon electrode (SPCE) for the selective sensing of 4-nitrophenol. The TcCuPtc was conjugated with conducting polymer of PANI through the electrostatic interaction and π-π electron conjugation, the polymer film of PANI to inhibit the leakage of TcCuPtc from the surface of the electrode. The prepared TcCuPtc@PANI were characterized and confirmed by scanning electron microscopy (SEM) with EDX, ATR-IR, UV-vis absorption spectroscopy, cyclic voltammetry, and differential pulse voltammetry techniques. The prepared TcCuPtc@PANI/SPCE showed an excellent electrocatalytic sensing of 4-NP in the linear concentrations from 3 to 500 nM with a LOD of 0.03 nM and a sensitivity of 8.8294 ㎂/nM cm-2. However, the prepared TcCuPtc@PANI/SPCE showed selective sensing of 4-NP in the presence of other interfering species. The practical applicability of the TcCuPtc@PANI/SPCE was employed for the sensing of 4-NP in different water samples by standard addition method and showed satisfactory recovery results.

Voltammetric Determination of Copper(II) at Chemically Modified Carbon Paste Electrodes Containing Alga

  • Bae, Zun-Ung;Kim, Young-Lark;Chang, Hye-Young
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.611-615
    • /
    • 1995
  • The design of appropriate chemically modified electrodes should allow development of new voltammetric measurement schemes with enhanced selectivity and sensitivity. Microorganism like algae has high ability to trap toxic and heavy metal ions and different affinities for metal ions. A copper(II) ion-selective carbon paste electrode was constructed by incorporating alga Anabaena into a conventional carbon paste mixture, and then the film of 10% Nafion was coated to avoid the swelling of the electrode surface. Copper ion could be deposited at the 25% algamodified electrode for 15 min without the applied potential while stirring the solution by only immersing the electrode in a buffer (pH 4.0) cot1taining copper(II). Temperature was controlled at $35^{\circ}C$. After preconcentration was carried out the electrode was transferred to a 0.1 M potassium chloride solution and was reduced at -0.6 volt at $25^{\circ}C$. The differential pulse anodic stripping voltammetry was employed. A well-defined oxidation peak could be obtained at -0.1 volt (vs SCE). In five deposition / measurement / regeneration cycles, the responses were reproducible and relative standard deviations were 3.3% for $8.0{\times}10^{-4}M$ copper(II). Calibration curve for copper was linear over the range from $2.0{\times}10^{-4}M$ to $1.0{\times}10^{-3}M$. The detection limit was $7.5{\times}10^{-5}M$. Studies of the effect of diverse ions showed that the coexisting metal ions had little or no effect for the determination of copper. But anions such as cyanide. oxalate and EDTA seriously interfered.

  • PDF

Copper(II) Selective PVC Membrane Electrodes Based on Schiff base 1,2-Bis (E-2-hydroxy benzylidene amino)anthracene-9,10-dione Complex as an Ionophore

  • Jeong, Eun-Seon;Lee, Hyo-Kyoung;Ahmed, Mohammad Shamsuddin;Seo, Hyung-Ran;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권2호
    • /
    • pp.401-405
    • /
    • 2010
  • The Schiff base 1,2-bis(E-2-hydroxy benzylidene amino)anthracene-9,10-dione has been synthesized and explored as ionophore for preparing PVC-based membrane sensors selective to the copper ($Cu^{2+}$) ion. Potentiometric investigations indicate high affinity of these receptors for copper ion. The best performance was shown by the membrane of composition (w/w) of ionophore: 1 mg, PVC: 33 mg, DOP: 66 mg and KTpClPB as additive were added 50 mol % relative to the ionophore in 1 ml THF. The proposed sensor's detection limit is $2.8{\times}10^{-7}$ M over pH 5 at room temperature (Nernstian slope 31.76 mV/dec.) with a response time of 15 seconds and showed good selectivity to copper ion over a number of interfering cations.

구리 나노 입자에 산-보조 레이저 공정을 적용한 구리 전극 제작 공정 개발 및 투명·유연 전극으로 활용 (Cu Electrode Fabrication by Acid-assisted Laser Processing of Cu Nanoparticles and Application with Transparent·Flexible Electrode)

  • 조현민;권진형;하인호;고승환
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.121-121
    • /
    • 2018
  • Copper is a promising electronic material due to low cost and high electrical conductivity. However, the oxidation problem in an ambient condition makes a crucial issue in practical applications. In here, we developed a simple and cost-effective Cu patterning method on a flexible PET film by combining a solution processable Cu nanoparticle patterning and a low temperature post-processing using acetic acid treatment, laser sintering process and acid-assisted laser sintering process. Acid-assisted laser sintering processed Cu electrode showed superior characteristics in electrical, mechanical and chemical stability over other post-processing methods. Finally, the Cu electrode was applied to the flexible electronics applications such as flexible and transparent heaters and touch screen panels.

  • PDF