• 제목/요약/키워드: Copper/low k

검색결과 594건 처리시간 0.03초

In-situ Characterization of Electrochemical and Frictional Behaviors During Copper CMP

  • 엄대홍;강영재;박진구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.227-230
    • /
    • 2004
  • As the organic acids were added in the slurry, zeta potential of alumina was changed to negative value and IEP value was shifted from alkaline to acidic pH. In citric acid based slurry, Cu surface continuously dissolved and etching depth linearly increased. On the contrary, passivation layer was grown on Cu surface in oxalic acid based slurry. As the platen rotation speed increased, Preston coefficient decreased in both slurries. With oxalic acid based slurry, at low velocity, removal rate is high value because of high friction force compared to citric acid based slurry. As platen velocity increased, removal of Cu in citric acid based slurry became higher value than oxalic acid based slurry. Typical lubrication behaviors were observed in both slurries. As Sommerfeld number increased, COF values gradually decreased and then re-increased. It indicated that lubrication was changed to direct contact or semi-direct contact mode to hydro-lubrication mode.

  • PDF

Ultra Low Field Sensor Using GMI Effect in NiFe/Cu Wires

  • Kollu, Pratap;Kim, Doung-Young;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • 제12권1호
    • /
    • pp.35-39
    • /
    • 2007
  • A highly sensitive magnetic sensor using the Giant MagnetoImpedance effect has been developed. The sensor performance is studied and estimated. The sensor circuitry consists of a square wave generator (driving source), a sensing element in a form of composite wire of a 25 $\mu$m copper core electrodeposited with a thin layer of soft magnetic material ($Ni_{80}Fe_{20}$), and two amplifier stages for improving the gain, switching mechanism, scaler circuit, an AC power source driving the permeability of the magnetic coating layer of the sensing element into a dynamic state, and a signal pickup LC circuit formed by a pickup coil and an capacitor. Experimental studies on sensor have been carried out to investigate the key parameters in relation to the sensor sensitivity and resolution. The results showed that for high sensitivity and resolution, the frequency and magnitude of the ac driving current through the sensing element each has an optimum value, the resonance frequency of the signal pickup LC circuit should be equal to or twice as the driving frequency on the sensing element, and the anisotropy of the magnetic coating layer of the sensing wire element should be longitudinal.

Primary study on metal amounts in Lophius piscatorius Linnaeus, 1758 obtained from fish markets in Sinop, Turkey

  • Bat, Levent;Yardim, Oztekin;Oztekin, Aysah;Sahin, Fatih;Arici, Elif
    • 식품보건융합연구
    • /
    • 제6권1호
    • /
    • pp.21-27
    • /
    • 2020
  • The levels of five heavy metals (mercury, cadmium, lead, copper and zinc) were analyzed in edible tissues of Lophius piscatorius Linnaeus, 1758 marketed in Sinop coasts of the Black Sea by using inductively coupled plasma mass spectrometry. With the present study, heavy metal values of this fish in the Black Sea were examined for the first time. The mean concentrations in mg kg-1 wet wt. of Hg, Cd, Pb, Cu and Zn were 0.022, 0.009, 0.035, 6.3 and 16 mg kg-1 wet wt., respectively. The results of the present study indicate that the consumption of muscle from anglerfish can be considered safe in terms of permissible legal limits. It is clear that, Zn showed the high accumulation in muscle tissue followed by Cu, while non-essential metals Hg, Cd and Pb showed the low accumulation. This could be explained by the fact that Zn and Cu are essential elements in the bodies of living organisms and has an important role in different physiological processes. In the present study, heavy metal levels in angler fish were low. Likewise, the calculated HI values were lower than one. In conclusion, the results of the present study indicate that the consumption of muscle from anglerfish can be considered safe in terms of permissible legal limits and hazard index values.

Chloride용액에서의 아말감부식에 대한 연구 (A STUDY ON THE CORROSION OF AMALGAMS IN CHLORIDE SOLUTION)

  • 엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.502-514
    • /
    • 1998
  • The purpose of this study is to observe the corrosion characteristcs of four dental amalgams(CAULK FINE CUT, CAULK SPHERICAL, DISPERSALLOY, TYTIN) and to determine a function of chloride concentration through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylinderical metal mold, and condensed by hydrolic pressure. Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 6 months. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam m KCl and KCl-NaCl solution, which had chlonde concentration of 0.4 g/l, 0.8 g/l, 1.2 gil, and 1.6 gil at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was - 1500mV ~+800mV(vs. S.C.E.) in the working electrode and the scan rate was 50mV/sec. The results were as follows, 1. The corrosion potential. the potential of anodic current peak, and transpassive potential in the solution of high chloride concentration shifted to more cathodic direction than those in the solution of low concentration, and the current density in the solution of high chloride concentration was higher than that in the solution of low concentration. 2. The corrosion potential, the potential of anodic current peak, and transpassive potential for CAULK FINE CUT amalgam were the most cathodic among the others, and the current density were the highest among the others. 3. In the solution of low chloride concentration, the corrosion potential, the potential of anodic current peak, and transpassive potential for DISPERSALLOY were the most anodic among the others, however in the solution of high chloride concentration, those for TYTIN were the most anodic among the others. 4. The anodic polarization curve for CAULK SPHERICAL was similar to that for high copper amalgams.

  • PDF

과테말라 Estancia de la Virgen 지역 금-은-동-비스무스 광화대의 산상과 광물특성 (Occurrence and Mineral Characteristics of Au-Ag-Cu-Bi Bearing Quartz Veins in the Estancia de la Virgen area, Guatemala)

  • 신의철;김수영;홍세선;김인준
    • 자원환경지질
    • /
    • 제31권6호
    • /
    • pp.463-472
    • /
    • 1998
  • 이 연구는 과테말라 에스탄시아 데 라 비르겐 (Estancia de la Virgen) 지역에 분포하는 광화대의 산상과 광물특성을 밝혀내기 위해 수행되었다. 이 연구를 위해 1:2,000 축척의 정밀광상 지질조사가 이루어졌다. 금-은 광화작용은 산 아구스틴 (San Agustin) 단층과 카바나스 (Cabanas) 단층사이의 단층 블럭내에 발달하며 단층구조에 의한 규제를 받았다. 금은 미량에서 부터 최고 72 g/t, 은은 미량에서 초고 180 g/t까지의 품위를 보인다. 정밀광상 지질조사에 의하면 석영맥은 북동방향으로 연장 500 m 이상 추적되며 연속성은 불량하지만 1,000 m 이상 연장되는 양상을 보인다. 석영맥에서의 광물생성순서는 3개 단계를 나눌 수 있다. 1단계에는 황철석, 방연석, 섬아연석, 황동석이 일차 금-은 광물과 수반되며 2단계에는 휘동석, 코벨라이트, 리나라이트와 같은 Cu-Bi-Au-Ag 황화광물이 형성되었으며 이들은 대체로 방연석이나 황동석의 미세구조에 침착-부화되었다. 3단계에는 방연석, 섬아연석의 탄산염화작용, 방연석의 표성부화작용이 지표환경에서 일어났다. 이 과정에서 용탈된 일부 은이 지하수면 근처에서 산화작용이 일어나는 동안 동광석이나 방연석에 침착되었다. 섬아연석과 황동석에서 각기 Fe와 Zn의 함량이 적은 것은 이들 광물이 비교적 저온에서 형성되었음을 의미하며 이는 이전에 연구된 유체포유물의 균일화온도와도 일치한다.

  • PDF

Studies on the Production of Artificial Zeolite from Coal Fly Ash and Its Utilization in Agro-Environment

  • Lee, Deog-Bae;Henmi, Teruo;Lee, Kyung-Bo;Kim, Jae-Duk
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.401-418
    • /
    • 2000
  • 1. Production of the artificial zeolite from coal ash Coal fly ash is mainly composed of several oxides including $SiO_2$ and $Al_2O_3$ derived from inorganic compounds remained after burning. As minor components, $Fe_2O_3$ and oxides of Mg, Ca, P, Ti (trace) are also contained in the ash. These components are presented as glass form resulting from fusion in the process of the combustion of coal. In other word, coal ash may refer to a kind of aluminosilicate glass that is known to easily change to zeolite-like materials by hydrothermal reaction. Lots of hot seawater is disposing near thermal power plants after cooling turbine generator periodically. Using seawater in the hydrothermal reaction caused to produce low price artificial zeolite by reduction of sodium hydroxide consumption, heating energy and water cost. As coal ash were reacted hydrothermally, peaks of quartz and mullite in the ash were weakened and disappeared, and new Na-Pl peaks were appeared strengthily. Si-O-Si bonding of the bituminous coal ash was changed to Si-O-Al (and $Fe^{3+}$) bonding by the reaction. Therefore the produced Na-Pl type zeolite had high CEC of 276.7 $cmol^+{\cdot}kg^{-1}$ and well developed molecular sieve structure with low concentration of heavy metals. 2. Utilization of the artificial zeolite in agro-environment The artificial zeolite(1g) could remove 123.5 mg of zinc, 164.7 mg copper, 184.4 mg cadmium and 350.6 mg lead in the synthetic wastewater. The removability is higher 2.8 times in zinc, 3.3 times in copper, 4.7 times in cadmium and 4.8 times in lead than natural zeolite and charcoal powder. When the heavy metals were treated at the ratio of 150 $kg{\cdot}ha^{-1}$ to the rice plant, various growth inhibition were observed; brownish discoloration and death of leaf sheath, growth inhibition in culm length, number of panicles and grains, grain ripening and rice yield. But these growth inhibition was greatly alleviated by the application of artificial zeolite, therefore, rice yield increased $1.1{\sim}3.2$ times according to the metal kind. In addition, the concentration of heavy metals in the brown rice also lowered by $27{\sim}75%$. Artificial Granular Zeolites (AGZ) was developed for the purification of wastewater. Canon exchange capacity was 126.8 $cmol^+{\cdot}kg^{-1}$. AGZ had Na-Pl peaks mainly with some minor $C_3S$ peaks in X-ray diffractogram. In addition, AGZs had various pore structure that may be adhere the suspended solid and offer microbiological niche to decompose organic pollutants. AGZ could remove ammonium, orthophosphate and heavy metals simultaneously. Mixing ratio of artificial zeolite in AGZs was related positively with removal efficiency of $NH_4\;^+$ and negatively with that of $PO_4\;^{3-}$. Root growth of rice seedling was inhibited severely in the mine wastewater because of strong acidity and high concentration of heavy metals. As AGZ(1 kg) stayed in the wastewater(100L) for 4days, water quality turned into safely for agricultural usage and rice seedlings grew normally.

  • PDF

Comparisons of inorganic amounts in paddy fields, rice straw and seed with varying severity of brown spot caused by Cochliobolus miyabeanus

  • Yeh, Wan-Hae;Park, Yang-Ho;Kim, I-Yeol;Kim, Yong-Ki;Shim, Hong-Sik
    • 한국식물병리학회:학술대회논문집
    • /
    • 한국식물병리학회 2003년도 정기총회 및 추계학술발표회
    • /
    • pp.91.2-92
    • /
    • 2003
  • In order to elucidate influence of nutritional status on rice brown spot caused by Cochliobolus miyabeanus, rice cultivation soils and rice straws were collected from paddy fields where ice brown spot occurred severely, moderately, a little and none respectively. Rice plant materials were analyzed to measure inorganic nutrients in rice straws and rice seeds. Analysis of chemical properties of rice paddy soil showed that EC and contents of available phosphate, cation and silicic acid in soil with severe infections were lower than those in healthy soil. This result suggests that amount and holding capacity of nutrient contents in soils collected from paddy field with infection of C. miyabeanus are relatively low compared to those in soils collected from healthy paddy field. Analysis of inorganic nutrients in rice straws showed that amount of macronutrient elements such as silicic acids, available phosphate and total nitrogen, and micronutrients such as copper, iron and zinc in rice straws from paddy field with infection were lower than those in healthy soil. Especially amount of iron and silicic acid were very low in rice straws from paddy field soils with infection Amount of inorganic nutrients such as iron and zinc in rice seeds was the same trend as those of rice straws. These results showed that one of major factors affecting rice brown spot was amount of nutrient contents in soil and rice straw.

  • PDF

세관내 R-22 대체냉매의 응축열전달에 관한 연구 (The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes)

  • 손창효;정진호;오종택;오후규
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

드라이아이스 펠렛 세정 장치 및 공정개발 (Development of Equipment and Process on Dry Ice Blasting)

  • 박종수;김호태;김선근
    • 청정기술
    • /
    • 제10권3호
    • /
    • pp.121-130
    • /
    • 2004
  • 액체 탄산의 단열팽창하여 얻은 드라이아이스 snow로부터의 펠렛제조기와 이들 펠렛을 이용한 표면 세정용 블래스팅 장치를 설계 제작하였다. 본 블래스팅 장치는 적은 압력과 적은 량의 공기로도 다양한 오염물질 녹, 기름때, 라커막, 페인트 제거에 강한 세정력을 얻을 수 있었다. 이 때 호퍼 용량은 12 kg이고, 펠렛 분사량은 0-1.2 kg/min 까지 조절이 가능하였다. 드라이아이스 펠렛의 impact는 한계 거리 안에서는 거리에 무관하며, 드라이아이스 분사의 impact stress, 각도 및 질량 속도에 의존하였다. 또한 블래스팅의 세정력은 impact와 대상 물질의 열적 성질 및 표면 조도에 의존하였으며, 유리, 구리, 황동, 강철, 아크릴 기판의 순서로 감소하였다. 그리고 세정 속도는 같은 기판에 붙은 오염물의 경도, 부착력에 의존하였으며 그리스, 에폭시, 페인트 순으로 감소하였다. 사용 중 소음도는 대략 85-100 dBA이었다.

  • PDF

사파이어 의료용 나이프의 연삭가공에서 지그의 탄성계수가 날 부 형상에 미치는 영향 : 제2보 탄성계수와 치핑 현상의 검증 (Effect of the Elasticity Modulus of the Jig Material on the Blade Edge Shape in the Grinding Process of Sapphire Medical Knife - Part 2 Verification of the Chipping Phenomenon and Elastic Modulus of the Jig Material)

  • 신건휘;강병욱;곽태수
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.63-68
    • /
    • 2017
  • This study determines the selection of an appropriate jig material for the blade edge of the medical sapphire knife. The physical properties of the jig material affects the edge shape and chipping phenomenon in machining of the medical sapphire knife. If a grinding wheel is used, brittle workpieces such as sapphire are easily damaged by the propagation of cracks because the grinding force significantly increases. It is important to constantly maintain the grinding force in the grinding process of the brittle materials. The grinding force can be kept constantly by inducing the elastic deformation of the Jig material because the elastic deformation of brittle work-piece is negligibly low. The chipping phenomenon may be reduced by selecting the proper Jig material. Aluminum, copper, stainless steels and carbon steel were used as Jig materials. The experiment was conducted using a cast iron grinding wheel, which was installed on a conventional grinding machine with the ELID grinding system. The thickness and width of the chipping area were measured using an optical microscope and FE-SEM to analyze the shape of the blade edge. According to the experiment result, the chipping phenomenon decreased, and the sharp edge was formed when the jig materials with low elastic modulus were used.