• 제목/요약/키워드: CopA3

검색결과 443건 처리시간 0.021초

멀티형 히트펌프 시스템 컴퓨터 시뮬레이션과 실험적 검증 (Multi type heat pump system computer simulation and experimental verification)

  • 한도영;정민영
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.12-19
    • /
    • 2000
  • The multi type heat pump system may provide more energy savings and better environmental conditions than the single type heat pump system may do. In order to design a multi type heat pump system, it may be recommended to develop the system simulation program, which can predict the characteristics of the system such as unit capacities, power consumptions, and system COP's. In this study, the steady state simulation program of the multi type heat pump system was developed. The results from the simulation program were compared with those from the experimental tests which were performed in the environmental chamber, Cooling tests show 3.11% and 0.94% of error in capacity and COP, and heating tests show 3.30% and 1.90% of error in capacity and COP, respectively. Therefore, the steady state simulation program developed for this study can effectively be used for the design and the performance prediction of the multi type heat pump system.

  • PDF

태권도 품새 우수·비 우수선수 간 앞차고 몸돌아 옆차기의 성·패에 따른 균형성 비교 (Comparison between the Balance of Skilled and Less-Skilled Players during Successful and Failed Front Kick and Turning Side Kick Motions)

  • 류시현;류지선
    • 한국운동역학회지
    • /
    • 제22권3호
    • /
    • pp.285-293
    • /
    • 2012
  • The aim of this study is to identify the appropriate movement for maintaining postural balance during Front Kick and Turning Side Kick motions. To do so, ten Taekwondo athletes: five skilled players(S, body mass: $65.0{\pm}5.8kg$, height: $172.3{\pm}3.7cm$, age: $20.0{\pm}1.2yrs$, career: $9.0{\pm}1.9yrs$) and five less-skilled players(LS, body mass: $67.1{\pm}5.5kg$, height: $173.2{\pm}5.1cm$, age: $19.4{\pm}1.7yrs$, career: $9.6{\pm}1.7yrs$) participated in this study. A three-dimensional motion analysis was performed on the participants using eight infrared cameras and two force plate(sampling frequency of 200 Hz and 2000 Hz for S and LS players, respectively). The participants' motions were divided into: a front-kick phase(P1) and a turning-side-kick phase(P2). For P2(p<.05), the range and root mean square(RMS) of the ground reaction torque and the M-L mean velocity of COP were greater for LS than for S; similarly, for P2(p<.05), the M-L range, A-P range, and velocity of the COP were greater for LS than for S. Further, the M-L range and maximum velocity of the COP was greater for failure than for success(p<.05). The femoral biceps muscle for bending the knee joint was significantly stronger in S than in LS(p<.05). It is expected that these results will be useful in developing a training program for improving the balance and stability of Taekwondo poomsae athletes and improve their front-kick and turning-side-kick motions.

H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH)

  • 권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구 (In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System)

  • 신영기;양훈철;태춘섭;조수;김영일
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

태양열 구동 $NH_3/H_2O$ 흡수식 냉동기 리모델링 연구 (A Study on Remodeling for Solar driven $NH_3/H_2O$ absorption chiller)

  • 신유수;맹주성;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.37-43
    • /
    • 2003
  • The aim of this research is to study the feasibility of the solar(hot fluid) driven $NH_3/H_2O$ absorption chiller, made by re-manufacturing of Gas fired $NH_3/H_2O$ absorption chiller. This experimental study is performed with the temperature of the inlet hot fluid of generator. In order to determine the inlet temperature of the generator, which gives maximum COP, the experimental data are obtained with various hot fluid supply temperature in range of $130\sim170^{\circ}C$. Remodeled chiller is operated with periodical cooling effect, which due to mixture subcooled pool boiling, then the COP is evaluated in average. The maximum COP$(\sim0.36)$ is at $160^{\circ}C$. The temperature is stable operation temperature range of typical vacuum collector. It offers a feasibility of solar driven $NH_3/H_2O$ absorption chiller.

차량용 CO2 에어컨 사이클 성능 향상을 위한 일체형 팽창기-압축기 성능 해석 (An Analysis of the Performance of a Combined Expander-Compressor Unit for a CO2 Automotive Air Conditioning Cycle)

  • 최재웅;임정택;김현진
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.107-115
    • /
    • 2018
  • A design combining the use of a compressor and expander was introduced in order to improve the cycle performance of a $CO_2$ automotive air conditioning system. Both the compressor and expander used were of rotary vane type and were designed to share a common shaft in a housing. Numerical simulation was carried out to evaluate the merit of the combined unit. In a typical automotive air conditioning operating conditions, the COP of the system was improved by 8.7% by the application of the combined unit. The compressor input was reduced by 5.2% through use of the expander output. In addition, about 3.06% increase in the cooling capacity was obtained through isentropic expansion in the expander. Our study noted that, as the pressure difference between the gas cooler and the evaporator becomes larger, the COP of the system improved increases unless the mass flow rate in the expander exceeds that in the compressor.

R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석 (Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump)

  • 강변;조홍현
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

온실난방을 위한 히트펌프의 성능에 관한 연구 (A Study on the Greenhouse Heating Performance of Heat Pump System)

  • 윤용철;서원명;이석건
    • 한국농공학회지
    • /
    • 제40권3호
    • /
    • pp.94-102
    • /
    • 1998
  • This experiment was carried out to study on the effect of greenhouse heating by water-to-water heat pump system employing heating water tank(ground water) as the heat source. Followings are the results obtained from this study ; 1. The heat amount absorbed from evaporator and the heat amount rejected from condenser were approximately 9, 000~ 12, 000kcal/h and 13, 000~ 17, OOOkcal/h, respectively. 2. The heat efficiencies of evaporator and condenser used in this experiment were approximately 79% and 83%, respectively. 3. The maximum heating load estimated for the experimental greenhouse was about 18, 000 ~ 25, OOOkcal/h, which was found to be about 28 ~ 32% higher than the heating capacity of the heat pump system adopted for this experiment. 4. The coefficients of performance(COP) for the heat pump and the total heat pump system were approximately 2.9~3.5 and 1.5~2.4, respectively. 5. The coefficient of performance(COP) calculated from the Mollier Diagram was about 3.2 ~ 3.4, which was reasonably close to the COP estimated on the basis of measured values. 6. The temperature of experimental greenhouse heated by the heat pump system could be maintained about 12~15 。C higher than that of a control greenhouse.

  • PDF

Immediate Effects of Lumbar Rotational Mobilization on the One-Legged Standing Ability in Healthy Individuals: A Randomized Controlled Trial

  • Heo, Seo Yoon;Kim, Bo Kyung;Moon, Ok Kon;Choi, Wan Suk
    • 국제물리치료학회지
    • /
    • 제9권3호
    • /
    • pp.1521-1527
    • /
    • 2018
  • The original focus of this study was to investigate the immediate effects of lumbar rotational mobilization on the one-legged standing ability. Fifteen subjects (6 men and 9 women, mean age = 22.77 (SD = 1.21), mean height = 165.46cm (SD = 11.65), mean weight = 61.46kg (SD = 8.29) volunteers from healthy individuals were recruited and randomized to a lumbar rotational mobilization (LRM) group and a trunk rotational exercise (TRE) group. Mobilization (grade 3 or 4) was applied to the LRM group on the lumbar spine (L1 to L5) in a side-lying, and trunk twist exercise (left and right side) was applied the to the TRE group with lunge position. Center of pressure (COP) and the velocity of the center of pressure (VCOP) of each participant were measured as a balance ability through one leg standing position. Results are as follows. In within-group difference, the COP of the LRM group reduced during standing with the right foot, but the VCOP change of the LRM was not statistically significant. In between-groups difference, COP of TRE group was decreased compared with LRM group only during left leg standing in the eyes (p <.05). The results of this study suggest that LRM is more effective than TRE in improving balance ability.

용량가변 방식을 적용한 압축기의 성능연구 (Performance of Compressor with Variable Capacity)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • 에너지공학
    • /
    • 제13권3호
    • /
    • pp.214-218
    • /
    • 2004
  • 본 연구에서는 용량가변방식을 적용한 PWM 압축기의 냉방운전 시 소비전력 변화 및 성능향상을 조사하기 위해서 기존 및 개선된 압축기의 능력, 소비전력, COP를 측정하여 비교하였다. 압축기의 효율 향상을 위해 무부하 상태에서 압축기 운전콘덴서의 변경, 복수구동부의 교차운전, 그리고 주 전류단에 코일를 적용하여 소비전력의 변화를 측정하였다. 용량가변형인 PWM압축기는 압축기 능력이 증가함에 따라 소비전력과 COP가 선형적으로 증가하였다. 압축기의 운전 콘덴서를 바꾸어가면서 소비전력을 측정한 경우 소비전력의 최적점이 확인되었다. 한편, 복수 구동부의 적용으로 불필요한 과전압에 의한 소비전력을 감소할 수 있었다.