• Title/Summary/Keyword: Coordination time

Search Result 596, Processing Time 0.028 seconds

A Study on the Voltage Stabilization Method of Distribution System Using Battery Energy Storage System and Step Voltage Regulator

  • Kim, Byung-ki;Park, Jae-Beom;Choi, Sung-Sik;Jang, Moon-Seok;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.11-18
    • /
    • 2017
  • In order to maintain customer voltages within the allowable limit($220{\pm}13V$) as much as possible, tap operation strategy of SVR(Step Voltage Regulator) which is located in primary feeder, is widely used for voltage control in the utilities. However, SVR in nature has operation characteristic of the delay time ranging from 30 to 150 sec, and then the compensation of BESS (Battery Energy Storage System) during the delay time is being required because the customer voltages in distribution system may violate the allowable limit during the delay time of SVR. Furthermore, interconnection of PV(Photovoltaic) system could make a difficultly to keep customer voltage within the allowable limit. Therefore, this paper presents an optimal coordination operation algorithm between BESS and SVR based on a conventional LDC (Line Drop Compensation) method which is decided by stochastic approach. Through the modeling of SVR and BESS using the PSCAD/EMTDC, it is confirmed that customer voltages in distribution system can be maintained within the allowable limit.

Development of an Adaptive Overcurrent Relaying Algorithm for Distribution Networks Embedding a Large Scaled Wind Farm

  • Jang, Sung-Il;Kim, Ji-Won;Kim, Kwang-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.198-205
    • /
    • 2003
  • This paper proposes the adaptive relaying of protective devices applied in the neighboring distribution feeders for reliable and efficient operations of a wind farm interconnected with distribution networks by dedicated lines. A wind farm connected to an electric power network is one of the greatest alternative energy sources. However, the wind turbine generators are influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the dedicated power. Particularly, in cases of a fault happening in the neighboring distribution feeders, a wind farm might be accelerated until protective devices clear the fault. Therefore, the delayed operation time of protective devices for satisfying the coordination might overly expose the interconnected wind turbine generators to the fault and cause damage to them. This paper describes the proper delayed operation time of protective relay satisfying the coordination of the distribution networks as well as reducing damage on the interconnected wind farm. The simulation results for the Hoenggye substation model composed of five feeders and one dedicated line using PSCAD/EMTDC showed that the proper delayed time of protective devices reflecting the fault condition and the power output of the wind farm could improve the operational reliability, efficiency, and stability of the wind farm.

Development of Protection Coordination Algorithm for Smart Distribution Management System using Communication Method based on IEC61850 (IEC61850 기반의 통신방식을 이용한 스마트 배전운영시스템용 보호협조 알고리즘 개발)

  • Chu, Cheol-Min;Yun, Sang-Yun;Kwan, Seung-Chul;Chu, Kyung-Yong;Jin, Young-Kyu;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1412-1419
    • /
    • 2012
  • In this paper, we propose the protection coordination algorithm using communication methode based on IEC 61850. The communication protocol in power distribution management system has been issued by IEC standard, IEC61850 of them, which was made for substation automation system, has researched to apply into power distribution system, even though the standard is not a suitable for the system. In smart distribution management system' launched in 2009, the communication network based on the ethernet network for IEC 61850 has been designed to apply the self-healing concept, which is to perform the system protection through the communication between remote terminal units(RTU) according to the standard. However, it is first time to apply the scheme in the real. Thus, this paper proposed the protection algorithm and consideration for applying communication method and introduced the result of demonstration.

ISO Coordination of Generator Maintenance Scheduling in Competitive Electricity Markets using Simulated Annealing

  • Han, Seok-Man;Chung, Koo-Hyung;Kim, Balho-H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.431-438
    • /
    • 2011
  • To ensure that equipment outages do not directly impact the reliability of the ISO-controlled grid, market participants request permission and receive approval for planned outages from the independent system operator (ISO) in competitive electricity markets. In the face of major generation outages, the ISO will make a critical decision as regards the scheduling of the essential maintenance for myriads of generating units over a fixed planning horizon in accordance with security and adequacy assessments. Mainly, we are concerned with a fundamental framework for ISO's maintenance coordination in order to determine precedence of conflicting outages. Simulated annealing, a powerful, general-purpose optimization methodology suitable for real combinatorial search problems, is used. Generally, the ISO will put forward its best effort to adjust individual generator maintenance schedules according to the time preferences of each power generator (GENCO) by taking advantage of several factors such as installed capacity and relative weightings assigned to the GENCOs. Thus, computer testing on a four-GENCO model is conducted to demonstrate the effectiveness of the proposed method and the applicability of the solution scheme to large-scale maintenance scheduling coordination problems.

Agent_based Web Service Support using Decentralized Coordination Technique (비집중화된 조정 기법을 이용한 에이전트 기반 웹 서비스 지원)

  • Jung, Seul-Ki;Lee, Tae-Kyung
    • The KIPS Transactions:PartB
    • /
    • v.15B no.5
    • /
    • pp.449-456
    • /
    • 2008
  • This paper proposed the agent-based web service platform that works toward providing coordination technique on web environment. The system described in this paper is designed and implemented to support web services between agents while maintaining web service module. The agent perform user's request dynamically with the proposed LDL, and it offer possibility of coordinated web services by performing commitment process to perform their goals with mutual cooperation for grouped agents. On experiments to check an implemented system, we found that the cost of module retrieval time is reduced and users are accessible.

Effective Coordination Method of Multi-Agent Based on Fuzzy Decision Making (퍼지 의사결정에 기반한 멀티에이전트의 효율적인 조정방안)

  • Ryu, Kyung-Hyun;Chung, Hwan-Mook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.1
    • /
    • pp.66-71
    • /
    • 2007
  • To adapt environment changing high speed and improve rapidly response ability for variation of environment and reduce delay time of decision making inlet agents, the derivation of user's preference and alternative are required. In this paper, we propose an efficient coordination method of multi-agents based on fuzzy decision making with the solution proposed by agents in the view of Pareto optimality. Our method generates the optimal alternative by using weighted value. We compute importance of attributes of winner agent, then can obtain the priorities lot attributes. The result of our method is analyzed that of Yager's method.

Performance Improvement of DCF through Transmission Control (전송제어를 통한 DCF의 성능 향상)

  • Park, Jaesung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.12
    • /
    • pp.1811-1813
    • /
    • 2016
  • DCF (Distributed Coordination Function) resolves the channel contention problem in a distributed manner by forcing nodes to randomly choose a waiting time in a contention window. However, since the size of a contention is limited, the collision probability increases with the number of sending nodes. To resolve the problem, in this paper, we propose a transmission control method based on the minority game (MG). Each node can determine autonomously whether to send or not without message exchanges with other nodes to maximize its profit. Through simulation studies, we verify that the proposed method can improves the performance of DCF in terms of collision probability in a congestion situation.

Sensory Motor Coordination System for Robotic Grasping (로봇 손의 힘 조절을 위한 생물학적 감각-운동 협응)

  • 김태형;김태선;수동성;이종호
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.2
    • /
    • pp.127-134
    • /
    • 2004
  • In this paper, human motor behaving model based sensory motor coordination(SMC) algorithm is implemented on robotic grasping task. Compare to conventional SMC models which connect sensor to motor directly, the proposed method used biologically inspired human behaving system in conjunction with SMC algorithm for fast grasping force control of robot arm. To characterize various grasping objects, pressure sensors on hand gripper were used. Measured sensory data are simultaneously transferred to perceptual mechanism(PM) and long term memory(LTM), and then the sensory information is forwarded to the fastest channel among several information-processing flows in human motor system. In this model, two motor learning routes are proposed. One of the route uses PM and the other uses short term memory(STM) and LTM structure. Through motor learning procedure, successful information is transferred from STM to LTM. Also, LTM data are used for next moor plan as reference information. STM is designed to single layered perception neural network to generate fast motor plan and receive required data which comes from LTM. Experimental results showed that proposed method can control of the grasping force adaptable to various shapes and types of greasing objects, and also it showed quicker grasping-behavior lumining time compare to simple feedback system.

Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator (스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

Inter-cell Interference Coordination Method Based on Active Antenna System in Heterogeneous Networks (이종망 환경에서 능동 안테나 시스템 기반의 셀간 간섭 제어 방법)

  • Kim, Byoung-June;Park, Haesung;Kim, Duk Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.548-556
    • /
    • 2014
  • To cope with recently increasing demand for data traffics, heterogeneous networks have been actively studied, where small cells are deployed within a macro cell coverage with the same frequency band. To mitigate the interference from the macro cell to small cells, an enhanced Inter-cell Interference Coordination (eICIC) technique has been proposed, where ABS (Almost Blank Subframe) is used in time domain. However, there is a waste of resource since no data is transmitted in a macro-cell in ABS. In this paper, we propose a new interference management method by using a 3D sector beam based on Active Antenna System (AAS), where Genetic Algorithm (GA) is applied to reduce the antenna gain toward a small-cell. With the proposed scheme, the macro-cell and small cells can transmit data at the same time with the AAS antenna pattern generating reduced interference to small cells. The performance of the proposed scheme is evaluated by using an LTE-Advanced system level simulator.