• Title/Summary/Keyword: Cooling vest

Search Result 14, Processing Time 0.019 seconds

A Relation of Urbanization Entropy and Urban Heat Phenomenon (도시화 엔트로피와 도시 열현상과의 관계성)

  • Sangjun Kang
    • Journal of the Korean Regional Science Association
    • /
    • v.39 no.3
    • /
    • pp.3-12
    • /
    • 2023
  • The issue to be discussed is set as the relationship between urban fragmentation and urban heat phenomena. The fragmentation is recognized as a negative form that commonly occurs in the process of urbanization. The purpose of this study is to examine the relationship between urbanization entropy and heat phenomenon by looking at the five major cities in Korea. The employed methods are InVEST Urban Cooling Model and MSPA (Morphological Spatial Pattern Analysis) by using the meteological data for the July 2018. The major results are as follows; First, a low rank correlation(rho=-0.3) is found in the relation between entropy and Cooling Capacity Index (CCi). Second, a very high level of rank correlation is observed between entropy and Average Temperature(℃)(rho=0.9). The implications are that 1) a city with a large degree of sprawling development can have a negative effect on urban heat phenomena; 2) the composition of land use including dispersion and concentration in non-urbanized areas, which has the characteristics of open space, can affect the urban thermal environment. Due to the limited number of case studies, it is appropriate to understand that a possibility, not generalization, is observed between entropy and heat phenomena in urbanized areas.

Urban Heat Mitigation Effect Analysis based on the Land Use Location Distribution by Using an Ecosystem Service Valuation Model (생태계 서비스 가치평가 모형을 이용한 토지이용 위치분배에 따른 도시 열저감 효과분석)

  • Sangjun, Kang
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.6
    • /
    • pp.369-377
    • /
    • 2022
  • The purpose of this study is to explore whether open spaces with land use characteristics of forest green areas can have different influence on the urban heat reduction depending on the location distribution, through the case of Gangneung-si downtown area. As a research method, the InVest Urban Cooling Model, which is a thermal phenomenon analysis model, is employed based on the most recent data available in 2018. In order to focus on the effect of location distribution of open space in the city, the downtown area is set as the observation area, not the entire city. The analysis of the land use location distribution scenarios shows that large-scale forests or clustered forests are more effective in reducing atmospheric heat in the region than several small-scale forests.

Cooling Strategy for Improving the Performance of Endurance Sports in Heat (고온 환경에서 지구성 스포츠의 운동수행력 향상을 위한 냉각요법의 전략)

  • Park, Chan-Ho;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.27 no.5
    • /
    • pp.591-599
    • /
    • 2017
  • It is well established that endurance performance is negatively affected by environmental heat stress. Numerous scientific investigations have attempted to improve performance in the heat with pre-cooling and per-cooling for endurance athletes. Some cooling strategies are more logistically challenging than others, and thus are often impractical for use in training or competition. The purpose of this study was to review the literature on the use of cooling interventions in the improvement of performance and recovery from exercise-induced heat stress. We undertook an examination that focused on the effects of pre-cooling and per-cooling on the improvement in endurance performance and the effects of post-exercise cooling on recovery. The benefits for pre-cooling and per-cooling strategies undertaken in the laboratory setting could be employed by athletes who compete in hot environmental conditions to improve performance. Most laboratory studies have shown improvements in endurance performance following pre-cooling and per-cooling, and in recovery following post-cooling. Cooling strategies such as cooling vest, neck cooling collar, menthol and ice slurry are practically relevant to sports field. Cooling interventions that can be applied frequently to reduce thermal strain prior to, during and directly after training appear to be the best effective strategy to improve performance and recovery. Future research is warranted to investigate the effectiveness of practical pre-cooling and per-cooling strategies in competition or field settings.

Analysis of Cross Sectional Ease Values for Fit Analysis from 3D Body Scan Data Taken in Working Positions

  • Nam, Jin-Hee;Branson, Donna H.;Ashdown, Susan P.;Cao, Huantian;Carnrite, Erica
    • International Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.87-99
    • /
    • 2011
  • Purpose- The purpose of this study was to compare the fit of two prototype liquid cooled vests using a 3D body scanner and accompanying software. The objectives of this study were to obtain quantitative measurements of ease values, and to use these data to evaluate the fit of two cooling vests in active positions and to develop methodological protocol to resolve alignment issues between the scans using software designed for the alignment of 3D objects. Design/methodology/approach- Garment treatments and body positions were two independent variables with three levels each. Quantitative dataset were dependent variables, and were manipulated in 3x3 factorial designs with repeated measures. Scan images from eight subjects were used and ease values were obtained to compare the fit. Two different types of analyses were conducted in order to compare the fit using t-test; those were radial mean distance value analysis and radial distance distribution rate analysis. Findings- Overall prototype II achieved a closer fit than prototype I with both analyses. These were consistent results with findings from a previous study that used a different approach for evaluation. Research limitations/implications- The main findings can be used as practical feedback for prototype modification/selection in the design process, making use of 3D body scanner as an evaluation tool. Originality/value- Methodological protocols that were devised to eliminate potential sources of errors can contribute to application of data from 3D body scanners.