• 제목/요약/키워드: Cooling model and simulation

검색결과 380건 처리시간 0.024초

열간압연 고강도강의 온도 및 재질제어 (Temperature and Property Control of High Strength Steel in Hot Strip Mills)

  • 박철재
    • 한국생산제조학회지
    • /
    • 제20권6호
    • /
    • pp.817-823
    • /
    • 2011
  • This paper proposes a cooling stop temperature control(CST) and a phase transformation control(PTR) which aim at obtaining the uniform temperature and quality along the longitudinal direction of the high strength steel on the run-out table(ROT) process. The problems of the temperature control are analyzed for the conventional steel and the new control concepts are derived from a time-temperature transformation(TTT) diagram. The proposed control technologies are verified from the simulation results under the temperature prediction model by the heat transfer governing equation, and the temperature estimation simulator. It is shown through the field test of the hot strip mills that the phase transformation ratio of the high strength steel is considerably improved by the proposed temperature controls.

열 잉크젯 프린트헤드의 집중질량 모델링 (Lumped Modeling of Thermal Inkjet Print Head)

  • 이유섭
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.942-949
    • /
    • 2006
  • A lumped model is proposed to predict liquid ejection characteristics of a thermally driven inkjet print head. The model is based on a two-dimensional heat conduction equation, an empirical pressure-temperature equation and a nonlinear hydraulic flow-pressure equation. It has been simulated through the construction of an equivalent R-C circuit, and subsequently analyzed using SIMULINK and a circuit simulation tool, PLECS. Using the model, heating and cooling characteristics of the head are predicted to be in agreement with the IR temperature measurements. The effects of the head geometry on the drop ejection are also analyzed using the nonlinear hydraulic model. The present model can be used as a design tool for a better design of thermal inkjet print heads.

로터리 제습기의 단순 해석 모델 개발-I. 지배방정식의 근사적 해석 (Development of a Simple Analytical Model for Desiccant Wheels-I. Approximate Solution of the Governing Equations)

  • 김동선;최영돈;이대영
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.821-827
    • /
    • 2011
  • A simple analytical model has been developed from the approximate solution of the governing equations for desiccant wheels. The model has been compared with a numerical twodimensional transient model and found capable of making realistic prediction. The analytical model will be further developed to provide simple effectiveness correlations which can be useful for the rough design or long-term simulation of the desiccant wheels in DEC systems.

백신 수송용 포장재 내부에서 열 전달의 모델링 및 시뮬레이션 (Modeling and Simulation of Heat Transfer inside the Packaging Box for Vaccine Shipping)

  • 다오 반 둥;최호석;이성찬;배윤성
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.604-609
    • /
    • 2008
  • 본 연구에서는 세계보건기구의 기준을 만족시키기 위한 포장재 개발을 목적으로 백신 수송용 장방형 포장재 내부열 전달에 대한 모델링 및 시뮬레이션을 수행하고 이를 실험결과와 비교하였다. 장방형의 박스를 구형 박스로 전환하여 구상한 1차원 모델은 냉각공정의 경우에는 실험 결과와 비교적 잘 일치하는 결과를 보였으나, 가열공정에서는 실험결과와 상당한 차이를 보여주었다. 이는 가열공정을 계산할 때, 포장재 외부에서의 경계조건을 적절히 고려해주지 못한 결과로 사료된다. 그러나, 본 연구를 통하여 상전이 물질을 함유한 다층 벽을 통한 열 전달의 문제를 전산 모사할 수 있는 기본적인 알고리즘을 성공적으로 개발할 수 있었다.

IMPROVEMENT OF CUPID CODE FOR SIMULATING FILMWISE STEAM CONDENSATION IN THE PRESENCE OF NONCONDENSABLE GASES

  • LEE, JEHEE;PARK, GOON-CHERL;CHO, HYOUNG KYU
    • Nuclear Engineering and Technology
    • /
    • 제47권5호
    • /
    • pp.567-578
    • /
    • 2015
  • In a nuclear reactor containment, wall condensation forms with noncondensable gases and their accumulation near the condensate film leads to a significant reduction in heat transfer. In the framework of nuclear reactor safety, the film condensation in the presence of noncondensable gases is of high relevance with regards to safety concerns as it is closely associated with peak pressure predictions for containment integrity and the performance of components installed for containment cooling in accident conditions. In the present study, CUPID code, which has been developed by KAERI for the analysis of transient two-phase flows in nuclear reactor components, is improved for simulating film condensation in the presence of noncondensable gases. In order to evaluate the condensate heat transfer accurately in a large system using the two-fluid model, a mass diffusion model, a liquid film model, and a wall film condensation model were implemented into CUPID. For the condensation simulation, a wall function approach with a heat/mass transfer analogy was applied in order to save computational time without considerable refinement for the boundary layer. This paper presents the implemented wall film condensation model, and then introduces the simulation result using the improved CUPID for a conceptual condensation problem in a large system.

상변화를 이용한 Micro-actuator에 대한 해석 (Analysis on Phase-Change Based Micro-actuator)

  • 정재동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.108-112
    • /
    • 2000
  • This paper presents a mathematical model and simulation of the micro-actuator based on thermally induced liquid-vapor phase-change in a partially-filled closed cavity. The volume expansion by liquid-vapor Phase change can generate considerable forces and displacement $({\sim}50{\mu}m)$ required for commercial use. For optimum operation involving many cycles within the closed chamber, active(thermoelectric) heating and cooling is used. The optimization of the system is conducted according to the parameters such as input power and response time. The optimized performance of micro-actuator is reasonable compared to other actuators.

  • PDF

Parameterization for Longwave Scattering Properties of Ice Clouds with Various Habits and Size Distribution for Use in Atmospheric Models

  • Jee, Joon-Bum;Lee, Kyu-Tae
    • 대기
    • /
    • 제23권1호
    • /
    • pp.39-45
    • /
    • 2013
  • A parameterization for the scattering of longwave radiation by ice clouds has been developed based on spectral scattering property calculations with shapes and sizes of ice crystals. For this parameterization, the size distribution data by Fu (1996) and by Michell and Arnott (1994) are used. The shapes of ice crystal considered in this study are plate, solid column, hollow column, bullet-rosette, droxtal, aggregate, and spheroid. The properties of longwave scattering by ice crystals are presented as a function of the extinction coefficient, single-scattering albedo, and asymmetry factor. The heating rate and flux by the radiative parameterization model are calculated for wide range of ice crystal sizes, shapes, and optical thickness. The results are compared with the calculated results using a six-stream discrete ordinate scattering algorithm and Chou's method. The new method (with various habits and size distributions) provides a good simulation of the scattering properties and cooling rate in optically thin clouds (optical thickness < 5). Depending on the inclusion of scattering by ice clouds, the errors in the calculation of the cooling rates are significantly different.

Server Cooling 알고리즘울 이용한 서비스 객체 이주시의 동기화 알고리즘 (A synchronization algorithm of migrating service object using Server Cooling algorithm)

  • 이준연;김창민
    • 한국정보처리학회논문지
    • /
    • 제7권3호
    • /
    • pp.953-961
    • /
    • 2000
  • In this paper, we propose the algorithm which solve synchronization problem happened migrating service objects. Load imbalance is occurred due to allocate different amount of load to be proposed to each node in distribute system. To solve this problem, the service objects have to be migrated from heavily loaded node to lightly loaded node. And in such a process, the synchronization problem may occur when client request a service object migrated incompletely. Therefore, we describe the environment of executing service objects, the importer/exporter/trader model compatible with migration of service objects, and appropriate migration algorithm, Finally, we analyze the conditions of problems, and propose the solution of each situations. Also, the performance advantages of using proposed algorithms are quantified through a simulation study.

  • PDF

ANALYSIS OF THE FIXED BED REACTOR FOR DME SYNTHESIS

  • Song, Dae-Sung;Ahn, Sung-Joon;Cho, Won-Jun;Park, Dal-Keun;Yoon, En-Sup
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2007년도 춘계학술발표회 논문집
    • /
    • pp.27-32
    • /
    • 2007
  • Dimethyl Ether (DME, $CH_3OCH_3$) is the simplest ether and is considered as one of the leading candidates in the quest for a substitute fur petroleum-based fuels. In this work, we analyzed the one-step synthesis of DME in a shell and tube type fixed bed reactor and carried out a simulation with a one-dimensional, steady state model of a heterogeneous catalyst bed, while taking into consideration the heat and mass transfer between the catalyst pellets and reactants gas and the effectiveness factor of the catalysts, together with the reactor cooling through the reactor tube wall. The reactor simulation was carried out under steady state condition and we compared the simulation results with the experimental data obtained from operations of a pilot-scale reactor and found good agreement between them.

  • PDF

광학식 대용량 정보저장장치의 냉각용 펜의 열유동 해석 (Heat and Flow Analysis for Cooling Fan for an Optical Archive System)

  • 김재후;임윤철
    • 정보저장시스템학회논문집
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 2015
  • An archive system is designed to store data for a long time without loss. However, many important factors such as temperature, dust, vibration, and humidity must be considered to design a successful archive system. Read/write devices, for example optical disk drives(ODDs), in an archive system generate heat while they are in operation. Fans are usually used to remove heat but the air flow accompanies dust into the system result in system failure. In this study, an archive system with six ODDs is chosen as an analysis model and flow together with temperature distributions are computed using a CFD simulation package. Flow analysis is focused on four cooling fans at the rear panel and temperature distribution is studied for various cases of fan operation. From the temperature point of view, fans give significant effects on $4^{th}$ to $6^{th}$ ODDs compared to the $1^{st}$ to $3^{rd}$ ODDs. Also, it is noticed which fan is the most important as far as cooling is concerned.