• Title/Summary/Keyword: Cooling load rate

Search Result 193, Processing Time 0.027 seconds

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode (냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Chung, Hyun-Joon;Joo, Young-Ju;Kang, Hoon;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

EFFECTS OF DIFFERENT COOLING TECHNIQUES ON DRAUGHT CAPACITY OF BUFFALO

  • Bunyavejchewin, P.;Kaewsomprasong, K.;Chotemethepirom, S.;Tanta-ngai, B.;Tajima, A.;Chikamune, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.2
    • /
    • pp.131-136
    • /
    • 1991
  • Four male swamp buffaloes weighing $460.5{\pm}44.6kg$ were used to study the effects of different cooling techniques on draught capacity. Each animal carted an 882 kg load on the same asphalt road for one hour during four different time periods: 9:00-10:00 A.M., 10:30-11:30 A.M., 2:00-3:00 P.M. and 3:30-4:30 P.M. Simultaneously, all animals were subjected to five different treatments on five days of similar environmental conditions. In Treatment 1, animals were put stationary in a field and did no work; in Treatment 2, animals were worked without any cooling method; in Treatment 3, fifteen-minute wallow was allowed to animals prior to working; in Treatment 4, animals were covered with wetted jute bags while working, and in Treatment 5, two buckets of water were poured over the buffaloes' trunks just prior to working. The experiment was conducted from April to July 1989, when the weather was very hot. It was found that cooling methods and working times did not affect the draught efficiency of buffaloes during the one hour, but did affect physiological traits. The work load had a larger partial effect on physiological responses of buffalo other than respiration rate than did climatic variables except on the respiration rate of the buffaloes. One cooling technique that seemed to slow the increase of body temperature while working was covering the buffalo's back with wetted jute bags. Animals working at different times had significant differences in the increase of physiological traits except pulse rate.

Study on TES system application for industrial production facility (축냉시스템의 산업용 생산설비 적용에 대한 고찰)

  • Park, C.H.;Hong, S.S.;Kim, J.R.;Park, S.S.;Hwang, H.S.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

The Study of Economical Efficiency for the Ice Storage System of more Energy Consumption Building (에너지 다소비형 건물 축냉 시스템의 경제성에 관한 연구)

  • Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.733-738
    • /
    • 2012
  • It is important issue to reduce the electric energy to save the operating cost of HVAC system. Even if electrical energy is the clean energy, it is difficult and takes high cost for storage of electricity. These cause the high peak load of electric energy for HVAC in summer season. In korea, government impose the electric charge with several grade for the purpose of cut-off the peak load of electricity. Government has a policy to support to design and install the heat/ice storage system using midnight electricity. In this study, analysis of cooling load and operating characteristics for ice storage system are performed. And, also economical efficiency is compared between ordinary charge system of electricity and midnight rate charge of electricity. The systematic and economical supports are needed for expansion of usage of energy saving equipments.

A Study on the Evaluation of Cooling Demand using Cooling Gas Sales (냉방용 가스사용을 중심으로 추정한 냉방전력수요 평가)

  • KIM C.S.;Rhee C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.660-662
    • /
    • 2004
  • Cooling demand in Korea has increased constantly. Furthermore, an evaluation and savings of cooling demand has impacted on summer DSM and investment in Korea. Absorbed cooling system uses gas. It could achieve reductions in summer peak load and increase gas demand simultaneously. However its efficiency rate is lower than electric system. Gas cooling system uses separate meter. Therefore we could analyze monthly cooling demand and derive annual uses pattern. This paper analyzes demand pattern of gas cooling and its effects on electricity savings. Also this paper presents the course of policy in electricity sector on spreading of gas cooling measures.

  • PDF

Effects of Inlet Water Temperature and Heat Load on Fan Power of Counter-Flow Wet Cooling Tower (입구 물온도와 열부하가 냉각탑의 팬동력에 미치는 영향 분석)

  • Nguyen, Minh Phu;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.267-273
    • /
    • 2013
  • In order to provide effective operating conditions for the fan in a wet cooling tower with film fill, a new program to search for the minimum fan power was developed using a model of the optimal total annual cost of the tower based on Merkel's model. In addition, a type of design map for a cooling tower was also developed. The inlet water temperature and heat load were considered as key parameters. The present program was first validated using several typical examples. The results showed that for a given heat load, a three-dimensional graph of the fan power (z-axis), mass flux of air (x-axis, minimum fan power), and inlet water temperature (y-axis, maximum of minimum fan power) showed a saddle configuration. The minimum fan power increased as the heat load increased. The conventionally known fact that the most effective cooling tower operation coincides with a high inlet water temperature and low air flow rate can be replaced by the statement that there exists an optimum mass flux of air corresponding to a minimum fan power for a given inlet water temperature, regardless of the heat load.

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean (태안 시설원예단지의 온실 냉난방 부하 분석)

  • Suh, Won-Myung;Bae, Yong-Han;Heo, Hae-Jun;Kwak, Cheul-Soon;Lee, Suk-Gun;Lee, Jong-Won;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.45-52
    • /
    • 2009
  • This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.