• 제목/요약/키워드: Cooling line

검색결과 273건 처리시간 0.023초

열연공정의 온라인 변태율 측정장치 (On-line measurement of metallurgical transformation in hot-rolled steel)

  • 김상영;강명구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 1997
  • The mechanical properties of a hot rolled steel is mostly governed by a cooling control on the run out table. During the cooling control, the hot rotted steel performs a metallurgical transformation(austenite ${\to}$ ferrite) which can be measured with a magnetic flux detector. The magnetic flux detector consisting of exciting and detecting coil can estimates the metallurgical transformation by measuring the variation of permeability in steel. We developed the method of detecting the magnetic property of hot rolled steel and processing the measured signal, Which makes possible to measure on-line metallurgical transformation.

  • PDF

레이저를 이용한 LCD 유리 절단 기술

  • 정재용;오대현;유기룡;이천;이우영
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2005년도 춘계 학술대회
    • /
    • pp.219-223
    • /
    • 2005
  • Nowadays laser cutting is the most promising method of cutting FPD(Flat Panel Display) glass in mass-production line. And this method can also be used to cut other brittle materials such as quartz, sapphire, ceramic and semiconductor The concept of this method is shown in picture 1. Laser beam heats glass up to strain point, not to melting point and cooling system chills glass to induce maximun thermal stress in glass surface and then the thermal stress generates micro thermal crack, in other words blind depth of crack, along laser beam and cooling line.

  • PDF

공조 시스템용 DDC의 온라인 최적제어에 관한 연구

  • 안병천
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1072-1078
    • /
    • 2001
  • The real time optimal control algorithm of the DDC controller for chilled water and supply air temperature set-point of heating, ventilating, air-conditioning and refrigeration systems has been researched for minimization of the total power which is consumed by the chiller, chilled water pump and air handing unit fan. The study has been done by using TRNSYS program in order to analyze the central cooling system in terms of the environmental variables such as indoor cooling lead and wet-bulb temperature. This optimal control alogorithm saves more energy and is suitable for real time on-line control in comparison with conventional method.

  • PDF

스팀사출성형에 의한 공정의 최적화 (Process optimization for the steam injection molding)

  • 문영대
    • Design & Manufacturing
    • /
    • 제9권2호
    • /
    • pp.10-15
    • /
    • 2015
  • The water has been the suitable for the cooling medium until now. But the water as cooling medium seem to have the limit for high speed injection. The steam plastic molding injection use the steam as the medium when raise the mold temperature. The weld line has been the major quality problems in a plastic injection parts to be difficult to be solved. These problems in injection-molded plastic parts are difficult to find the reason because these issues are usually in tradeoff realtions with each other. The purpose of this paper is to obtain the optimum injection moulding condition for improving the quality of plastic injection parts and to inquire the productivity improvement with the measured cycle time by steam plastic moluding injection. Based on these numerical results, the guidelines of mould design and injection processing condition were established. As a result, the improvement of quality and the reduction of cycle time was achieved.

  • PDF

극저온 냉동기를 활용한 기체수소 예냉 시스템의 검증에 관한 연구 Part I: 실험적 연구 및 이론적 분석 (Study on Validity of Pre-cooling System for Hydrogen Gas Using Cryocooler Part I: Experimental Investigation and Theoretical Analysis)

  • 하동우;노현우;서영민;구태형;고락길
    • 한국수소및신에너지학회논문집
    • /
    • 제34권4호
    • /
    • pp.350-357
    • /
    • 2023
  • In this study, the experimental investigation and theoretical analysis were conducted to verify the cooling capacity of the cryocooler used for pre-cooling of hydrogen gas. The effect of the flow rate on a copper pipe attached to the bottom of the cryocooler, which has a coil shape in a hydrogen line, was investigated. Temperature sensors were strategically placed at various positions on the cryocooler to analyze the temperature variations with respect to the flow rate. In this study, the thermal properties of hydrogen for the pressure and temperature were utilized using REFPROP to analyze the cooling capacity of the cryocooler. Based on the experimental results derived from this study, the cooling capacity of the cryocooler for pre-cooling hydrogen gas was considered by calculating the cooling temperature according to the flow rate through theoretical analysis.

비집속빔을 이용한 $CO_2$ 레이저 빔 조사강화 ($CO_2$ Laser Irradiation Strengthening by Defocused Beam)

  • 서정;이제훈;강희신;김정오;이문용;오상진;이규현
    • 한국레이저가공학회지
    • /
    • 제6권2호
    • /
    • pp.1-7
    • /
    • 2003
  • Defocused CO$_2$ laser beam irradiation strengthening of 60kgf/$\textrm{mm}^2$ grade steel sheet was investigated to obtain the tensile strength similar to that of fully penetrated one by the focused beam. The melted line width by the defocused beam was 3∼4 times larger compared to that of the focused beam. However, the increase of tensile strength with 1 line irradiation by the defocused beam was similar to that of 2~3 lines by the focused beam. The increase(37.6%) of bending strength with 1 line by the defocused beam was higher than the increase(12.9%) of tensile strength. Also, the effect of cooling gas to strengthening was observed.

  • PDF

퀜치 시 초전도 한류기의 온도 (Temperature Behavior of Superconducting Fault Current Limiters during Quenches)

  • 김혜림;심정욱;현옥배
    • Progress in Superconductivity
    • /
    • 제6권2호
    • /
    • pp.108-112
    • /
    • 2005
  • We investigated temperature behavior of superconducting fault current limiters (SFCLs) during quenches. Knowledge on temperature behavior during quenches is important to the design of SFCLs, because the temperature of SFCLs is related to their stability. SFCLs were fabricated by patterning $Au/YBa_2Cu_3O_7$ thin films grown on sapphire substrates into meander lines by photolithography. A gold film grown on the back side of the substrate was patterned into a meander line, and used as a temperature sensor. The front meander line was subjected to simulated AC fault currents, and the back line to DC current. They were immersed in liquid nitrogen during the experiment for effective cooling. Overall, temperature at the back side of SFCLs was close to that at the front side. It was closer at the beginning of faults, and at lower applied voltages. Temperature distribution at the back side was even except at the edge, as at the front side. These results tell that the whole SFCL was heated to similar degree during quenches, and that effective cooling of SFCLs at the back side is as important to the stability of SFCLs as at the front side. The results could be explained with the concept of heat transfer within the film.

  • PDF

동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가 (Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions)

  • 이승찬;김태안;태상진;정규하;문제명;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF

과냉비등류에 있어서 동블록을 이용한 과도적 냉각실험 (Transient cooling experiments with a cooper block in a subcooled flow boiling system)

  • 정대인;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.72-79
    • /
    • 1987
  • When the wall temperature is very high, a stable vapor film covers the heat transfer surface. The vapor film creates a strong thermal resistance when heat is transferred to the liquid though it. This phenomenon, called "film boiling" is very important in the heat treatment of metals, the design of cryogenic heat exchangers, and the emergency cooling of nuclear reactors. In the practical engineering problems of the transient cooling process of a high temperature wall, the wall temperature history, the variation of the heat transfer coefficients, and the wall superheat at the rewetting points, are the main areas of concern. These three areas are influenced in a complex fashion such factors as the initial wall temperature, the physical properties of both the wall and the coolant, the fluid temperature, and the flow state. Therefore many kinds of specialized experiments are necessary in the creation of precise thermal design. The object of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The block was 240 mm high and 79 mm O.D.. The coolant flowed throuogh the center of a 10 mm diameter channel in the copper block. In the copper block, three sheathed thermocouples were placed in a line perpendicular to the flow. These thermocouples were used to take measurements of the temperature histories of the copper block.

  • PDF