• Title/Summary/Keyword: Cooling line

Search Result 271, Processing Time 0.024 seconds

The Estimation of Curvature Deformation of Steel Plates in Water Cooling Process after Line Heating (선상 가열시 수냉 효과를 고려한 강판의 변형 추정에 관한 연구)

  • HwangBo, Hyeok;Yang, Park-Dal-Chi
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.209-212
    • /
    • 2006
  • Line heating with water cooling is generally adapted process in the shipyards for the forming hull surface. The purpose of this paper is to develop a model of thermal deformation in water cooling process after the line heating. In order to simulate the cooling process, heat transfer analysis was performed by assuming the effects of water cooling as a negative heat-source. Experiment for the line heating with water cooling was performed for 9 models of plates in order to verify the cooling model. By using the suggested model for the water cooling process, it could be observed that the present method predict the plate deformations in the line heating more accurately.

  • PDF

A study on the simulation of water cooling process for the prediction of plate deformation due to line heating

  • Nomoto, Toshiharu;Jang, Chang-Doo;Ha, Yun-Sok;Lee, Hae-Woo;Ko, Dae-Eun
    • International Journal of Ocean System Engineering
    • /
    • v.1 no.1
    • /
    • pp.46-51
    • /
    • 2011
  • In a line heating process for hull forming, the phase of the steel transforms from austenite to martensite, bainite, ferrite, or pearlite depending on the actual speed of cooling following line heating. In order to simulate the water cooling process widely used in shipyards, a heat transfer analysis on the effects of impinging water jet, film boiling, and radiation was performed. From the above simulation it was possible to obtain the actual speed of cooling and volume percentage of each phase in the inherent strain region of a line heated steel plate. Based on the material properties calculated from the volume percentage of each phase, it should be possible to predict the plate deformations due to line heating with better precision. Compared to the line heating experimental results, the simulated water cooling process method was verified to improve the predictability of the plate deformation due to line heating.

Microstructural Features of Al Alloy 7N01 Welded by $CO_2$ Laser - Microsturctural Features of Full Penetration Joints - ($CO_2$ 레이저 용접한 7N01 Al합금의 미세조직 특징(I) - 완전용입 용접부의 미세조직 -)

  • 윤재정;강정윤;김인배;김대업
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.429-436
    • /
    • 2001
  • The effect of welding condition on the microstructures of the weld metal in A7N01 welded by $CO_2$ laser was investigated. The number of ripples was increased with decreasing power and increasing welding speed. In the bead without ripple lines, the subgrain microstructures distribution from the fusion line toward the center of the bead were in the order of cellular, dendritic and equiaxed dendrite. However, in the bead with ripple lines, cellular and dendritic were formed between the fusion boundary and the ripple line. Inaddition, those structures were also observed between the ripple line. Equiaxed dendrites were formed only at the center line region. Cellular and dendritics formed near the ripple line were larger than those formed near the fusion boundary. The cooling rates estimated by the dendrite arm spacing were in the range of 200 to 1150oC/s. Cooling rate was increased with decreasing the power and increasing the welding speed. Mg and Zn segregated at the boundaries of cellulars and dendritics, Mg was segregated more than Zn. The segregation of Mg and Zn decreased with increasing cooling rate. Hardness of the weld metal was lower than that of the base metal in all welding conditions and increased as the cooling rate increased.

  • PDF

On-line Measurement of Cooling Rate of a Fermenter and its Application for Fed-batch Control (발효조의 냉각량 연속 측정 및 이를 이용한 유가배양제어)

  • Heo, Won;Hong, Gun-Pyo
    • KSBB Journal
    • /
    • v.18 no.5
    • /
    • pp.418-423
    • /
    • 2003
  • A laboratory jar fermenter was modified to measure the duration for cooling water supply and the temperatures of the coolant at the inlet and outlet of water jacket. Successful operation of temperature control and on-line measurement was achieved by adjusting optimum parameters of the Proportion-Integral-Derivative temperature controller. The variables measured on-line were used to estimate cooling rates from empirical equations comprised of the time period of cooling water supply and the temperatures of coolant. The measured cooling rate showed a good correlation to the specific growth rate during batch cultivation of E. coli. Cooling rate was measured and applied to programmed cell growth in a fed-batch cultivations. Three fed-batch cultivations were demonstrated by feeding substrate to follow the programmed cooling rates increasing exponentially.

A Study on the Improvement of Cooling Efficiency for EMU by Changing the Operation Method of Line Flow Fans and Door Opening Systems (전동차의 라인데리아 및 출입문 작동 방법 변화를 이용한 냉방 효율 향상에 관한 연구)

  • Oh, Jun-Gyu;Won, Si-Tae;Nam, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.94-99
    • /
    • 2011
  • EMU(Electric Multiple Unit) of Seoul Metro are equipped with air conditioning and six line flow fans for air circulation. In summer, the air conditioning and line flow fans usually work at the same time. Recently, high oil price leads more people to use public transportation, which in turn makes them feel hotter inside the rolling stocks and complain about air conditioning state. In order to improve indoor air quality in summer, it is inevitable to increase the cooling capacity of air conditioners, which costs a lot of money. Thus, we need to raise cooling efficiency by rearranging existing devices effectively. In this study, we found a better way to improve refreshment inside the trains by changing the operation method of line flow fans and door opening systems. The results will help improve the cooling efficiency of EMU in summer. Also, more precise experiments and analyses of our data can lead to various methods to increase energy efficiency.

  • PDF

Prediction of Plate Deformation Considering Film Boiling in Water Cooling Process after Line Heating (선상가열시 수냉이 유발하는 막비등 현상을 고려한 판의 변형 예측)

  • Ha, Yun-Sok;Kim, Jung-Soo;Jang, Chang-Do
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.5 s.143
    • /
    • pp.472-478
    • /
    • 2005
  • From a rapid cooling to a slow cooling in the actual cooling process in shipyards, the phase of steel becomes martensite, bainite, ferrite, and pearlite. In order to simulate the cooling process, heat transfer analysis was performed considering the effects of impinging water jet, film boiling, and radiation. From above simulation it is possible to find the cooling speed at the inherent strain region and volume percentage of all phases in that region. By the suggested method based on the precise material properties calculated from volume percentage of all phases, it will be possible to predict the plate deformations by line heating more precisely. It is verified by comparing with some experimental results that the present method is very effective and efficient.

Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner (냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

A Study on Thermal Analysis of Dual Beam Laser Welding of Thin Metal Sheet (박판의 이중 빔 레이저 용접에서 열유동 해석에 관한 연구)

  • 김재웅
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.99-108
    • /
    • 1997
  • Analytical model for the temperature distribution and the cooling rate of weld in dual beam laser welding is presented for investigating the possibility of controling the cooling rate. The model is based on the solutions to the problem of heat flow due to the distributed and line heat sources for preheating and welding respectively in plates with finite thickness. The effects of beam power, beam distribution parameter, interbeam distance, and welding speed on the resulting temperature distribution and cooling rate are presented. The cooling rates of dual beam laser weld at the weld centerline under the investigated conditions are reduced to as one third of those of welds which were produced by single beam laser. And it appeared that the cooling rate of dual beam laser weld is strongly dependent on the process parameters of preheating laser beam power and welding speed.

  • PDF

Simulation of plate deformation due to line heating considering water cooling effects (수냉 효과를 고려한 선상가열에 의한 판 변형의 시뮬레이션)

  • Ko, Dae-Eun;Ha, Yun-Sok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2470-2476
    • /
    • 2011
  • Inherent strain method, a hybrid method of experimental and numerical, is known to be very efficient in predicting the plate deformation due to line heating. For the simulation of deformation using inherent strain method, it is important to determine the magnitude and the region of inherent strain properly. Because the phase of steel transforms differently depending on the actual speed of cooling following line heating, it should be also considered in determining the inherent strain. A heat transfer analysis method including the effects of impinging water jet, film boiling, and radiation is proposed to simulate the water cooling process widely used in shipyards. From the above simulation it is possible to obtain the actual speed of cooling and volume percentage of each phase in the inherent strain region of a line heated steel plate. Based on the material properties calculated from the volume percentage of each phase, it should be possible to predict the plate deformations due to line heating with better precision.

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.