• 제목/요약/키워드: Cooling gradient

검색결과 156건 처리시간 0.02초

분사구 인접영역에서의 막냉각에 관한 3차원 해석 (3-Dimensional Analysis for Film Cooling adjacent Injection Hole)

  • 이용덕;이재헌
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2590-2600
    • /
    • 1993
  • The present paper describes numerical predictions for the film cooling effectiveness from a row of hole at various injection ratios and injection alngles.Numerical calculations were performed to investigate film cooling effectiveness and the characteristics of flow and temperature distributions in the region near the downstream of injection hole including the region of adverse pressure gradient. The elliptic 3-dimensional governing equations with variable thermal properties were solved by SIMPLE algorithm. The results showed that the presence of adverse pressure gradient in the region near the downstream of injection hole induces large temperature gradient. At injection angle of $35^{\circ}$ the average film cooling effectiveness was increased as increased of injection ratio up to 1.0. At injection angle of $90^{\circ}$ however, the average film cooling effectiveness was decreased from injection ratio larger than 0.4.

화염법으로 제조된 TiO2 나노분말의 결정구조에 미치는 화염가스 유량의 영향 (Effect of the Flow Rate of Flame Gases on the Crystal Structure of TiO2 Nanopowder Synthesized by Flame Method)

  • 지현석;안재평;허무영;박종구
    • 한국분말재료학회지
    • /
    • 제10권6호
    • /
    • pp.448-455
    • /
    • 2003
  • $TiO_2$ nanopowder has been synthesized by means of the flame method using a precursor of titanium tetraisopropoxide (TTIP, Ti$(OC_3H_7)_4)$. In order to clarify the effect of cooling rate of hot flame on the formation of $TiO_2$ crystalline phases, the flame was controlled by varying the mixing ratio and the flow rate of gases. Anatase phase was predominantly synthesized under the condition having the steep cooling gradient in flame, while a slow cooling gradient enabled to form almost rutile $TiO_2$ nanopowder of above 95%.

자연대류를 고려한 전류도입선의 최적설계 (Optimal design of Current lead considering Natural convection)

  • 손봉준;설승윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.103-108
    • /
    • 2003
  • In this paper, the current lead for superconducting device is studied by numerical method. The current lead is cooled by surrounded $N_{2}$ gas by natural convection. The heat conduction equation for current lead and boundary layer equation for $N_{2}$ gas must be solved simultaneously. The boundary layer equation for $N_{2}$ gas is highly nonlinear for varied temperature of current lead. So the linearization method is adopted for simplicity. Numerical results using natural convection cooling are compared with the conventional cooling methods such as conduction cooling and vapor cooling methods. The main difference of natural convection cooing is the non-zero temperature gradient at the top of current lead for the minimum heat dissipation into superconducting devices. For the optimized conduction-cooling and vapor-cooling current leads, the temperature gradient at the top of current lead is zero. Also, the heat flow at the cold end is much smaller than conduction cooling case.

  • PDF

건물예냉과 실내온도의 선형상승에 의한 피크냉방수요 저감 (Reducing Peak Cooling Demand Using Building Precooling and Modified Linear Rise of Indoor Space Temperature)

  • 이경호;양승권;한승호
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.86-96
    • /
    • 2010
  • The paper describes development and evaluation of a simple method for determining gradient of modified linear setpoint variation to reduce peak electrical cooling demand in buildings using building precooling and setpoint adjustment. The method is an approximated approach for minimizing electrical cooling demand during occupied period in buildings and involves modified linear adjustment of cooling setpoint temperature between $26^{\circ}C$ and $28^{\circ}C$. The gradient of linear variation or final time of linear increase is determined based on the cooling load shape in conventional cooling control having a constant setpoint temperature. The potential to reduce peak cooling demand using the simple method was evaluated through building simulation for a calibrated office building model considering four different weather conditions. The simple method showed about 30% and 20% in terms of reducing peak cooling demand and chiller power consumption, respectively, compared to the conventional control.

경사기능성 세라믹/ 금속 복합재료의 열충격특성에 관한 연구 (A Study on Thermal Shock Characteristics of Functionally Gradient Ceramic/Metal Composites)

  • 송준희;임재규
    • 대한기계학회논문집A
    • /
    • 제20권7호
    • /
    • pp.2134-2140
    • /
    • 1996
  • This study was carried out to anlayze the heat-resistant characteristics of functionally gradient material(FGM) composed with ceramic and metal. The thermal fracture behavior of plasma-sprayed FGM and conventional coating material(NFGM) was exaimined by acoustic emession technique under heating and cooling. Furnace cooling and rapid cooling tests were used to examine the effect of temperature change under various conditions, respectively. At the high temperature above $800^{\circ}C$, it was shown that FGM gives higher thermal resistance compared to NFGM by AE signal and fracture surface analysis.

가스터빈블레이드에서 일렬의 제트에 의한 막냉각특성 연구 (Film Cooling by a Row of Jets in a Gas Turbine Blade)

  • 이용덕;이재헌
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1851-1865
    • /
    • 1994
  • The objective of the present study is to predict the film cooling effectiveness by a row of holes at various injection ratios and injection angles. Numerical calculations have been performed to investigate the characteristics of flow and temperature distributions in a region near the down-stream of injection hole including the region of adverse pressure gradient. The elliptic turbulent 3-dimensional governing equations with variable thermal properties using the low-Reynolds number k-$\bar{varepsilon}$ model was solved by SIMPLE algorithm. The results showed that the presence of adverse pressure gradient and secondary vortex in the region near the downstream of injection hole induces large temperature gradent. The $45^{\circ}$ injection has higher averaged film cooling effectiveness than $60^{\circ}$ injection. But neverthless the $90^{\circ}$ injection has greater deviation from a flat plate than $45^{\circ}$ and $60^{\circ}$ injection, the $90^{\circ}$ injection has higher averaged film cooling effectiveness than $45^{\circ}$ and $60^{\circ}$ injection in the region near the downstream of injection hole.

A meso-scale approach to modeling thermal cracking of concrete induced by water-cooling pipes

  • Zhang, Chao;Zhou, Wei;Ma, Gang;Hu, Chao;Li, Shaolin
    • Computers and Concrete
    • /
    • 제15권4호
    • /
    • pp.485-501
    • /
    • 2015
  • Cooling by the flow of water through an embedded cooling pipe has become a common and effective artificial thermal control measure for massive concrete structures. However, an extreme thermal gradient induces significant thermal stress, resulting in thermal cracking. Using a mesoscopic finite-element (FE) mesh, three-phase composites of concrete namely aggregate, mortar matrix and interfacial transition zone (ITZ) are modeled. An equivalent probabilistic model is presented for failure study of concrete by assuming that the material properties conform to the Weibull distribution law. Meanwhile, the correlation coefficient introduced by the statistical method is incorporated into the Weibull distribution formula. Subsequently, a series of numerical analyses are used for investigating the influence of the correlation coefficient on tensile strength and the failure process of concrete based on the equivalent probabilistic model. Finally, as an engineering application, damage and failure behavior of concrete cracks induced by a water-cooling pipe are analyzed in-depth by the presented model. Results show that the random distribution of concrete mechanical parameters and the temperature gradient near water-cooling pipe have a significant influence on the pattern and failure progress of temperature-induced micro-cracking in concrete.

열간 판재단조시 강괴 내부의 기공폐쇄에 관한 연구 (Study on Internal Void Closure in Slab ingot during Hot Plate Forging)

  • 조종래;김동권;김영득;이부윤
    • 소성∙가공
    • /
    • 제5권1호
    • /
    • pp.18-26
    • /
    • 1996
  • In order to investigate the effect of pre-cooling of ingot on void closure in hot plate forging the internal strain and stress distributions are examined quantitatively by using ABAQUS. Simula-tions are carried out on a large slab ingot having the same temperature and the temperature gradient induced by air-cooling. It is shown that pre-cooling produces little effect on the strain behavior but remarkable effect on the hydrostatic stress at the central zone of ingot. The main factors for crushing micro-voids are the effective strain and the time integral of hydrostatic stress in the region surrounding the voids. Based on regression analysis it was found that the distortion of void can be expressed as a polynomial function of the two factors.

  • PDF

매스콘크리트의 열경사 조절에 의한 수화열과 온도균열의 방지 (Innovative Transient Thermal Gradient Control to Prevent Early Aged Cracking of Massive Concrete)

  • 김성수;조태준;이정배
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.164-172
    • /
    • 2008
  • 초기 재령의 매스콘크리트는 양생과정에서 높은 온도를 유발한다. 수화열 저감 기법 중 내부구속이 지배적인 구조물에서 단면의 내외부 온도차를 관리하는 방식은 그 활용도가 매우 높다. 그러나 수화 균열을 예방하기위해 열경사를 조절하는 현재의 제한적인 방법은 콘크리트 중심과 표면 사이에 미세하거나 거대한 균열을 유발할 수 있다. 특히 냉각파이프를 이용하는 방법은 온도의 상승시에는 적용될 수 있지만, 내외부 온도차이가 심한 온도하강시의 대책으로는 적합하지 않다. 따라서 이 문제에 대한 해결방안으로 가열파이프를 동시에 사용하는 모델을 제안하여 유한요소법으로 해석하였다. 해석 결과, 제안된 냉각파이프와 가열파이프를 동시에 사용하는 방법이 열경사조절에 가장 효과적이며 이를 통해 온도균열을 효과적으로 제어할 수 있을 것으로 판단된다.