• Title/Summary/Keyword: Cooling fluid

Search Result 875, Processing Time 0.033 seconds

Fluid Flow and Heat Transfer Characteristics around a Surface-Mounted Module Cooled by Forced Air Flow by Piezoelectric Cooling Fan (압전세라믹 냉각팬에 의한 강제 공랭 모듈 주위의 유체유동과 열전달 특성)

  • Park, G.J.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.272-277
    • /
    • 2003
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. A flexible PZT fan with distortion in a fluid transport system of comparatively simple structure which was mounted on a PCB in a parallel-plate channel($450{\times}80{\times}700mm^3$) accelerates surrounding fluid locally. Input voltages of 20-100V and a resonance frequency of 23Hz were used to vibrate the cooling fan. Input power to the module was 4W. The cooling effect using a PZT fan was larger than that of free convection. Fluid flow around the module were visualized by using PIV system. The temperature distribution around heated module were visualized by using liquid crystal film(LCF). We found that the flow type was y-shaped and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

  • PDF

Numerical Thermo-Fluid Analysis to the Water Cooling Plate (IGBT 스택용 10kW급 수냉각판 열유동 수치해석)

  • Ryoo, Seong-Ryoul;Mock, Chin-Sung;Cho, Tae-Sik;Kim, Chul-Ju
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1298-1302
    • /
    • 2011
  • The present study deals with the results of a thermo-fluid analysis applied to the cooling plate of the water cooling system developed for IGBT stacks, which was designed to keep the power semi-conductors from over heating problems. The cooling plate is to absorb a maximum quantity of 10kW from 4 IGBTs which are to be placed on both sides of the cooling plate, 2 IGBTs of them on each surface. For the analysis, Adina of CFD Program was used and an analysis was conducted to obtain the knowledges on heat and mass flow at both the plate and fluid flow inside. For the simulation, the operational conditions of a temperature difference of $15^{\circ}C$ for the working fluid and a uniform heat flux of about 92000 $W/m^2$ on the surface in contact with an IGBTs.

  • PDF

A Numerical Study on Cavitation Suppression Using Local Cooling

  • Zhang, Yuan-Yuan;Sun, Xiao-Jing;Huang, Dian-Gui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.292-300
    • /
    • 2010
  • This study strives to develop an effective strategy to inhibit cavitation inception on hydrofoils by using local cooling technique. By setting up a temperature boundary condition and cooling a small area on the upper surface of a hydrofoil, the fluid temperature around the cooling surface will be decreased and thereby the corresponding liquid saturation pressure will drop below the lowest absolute pressure within the flow field. Hence, cavitation can never occur. In this paper, a NACA0015 hydrofoil at $4^{\circ}$ angle of attack was numerically investigated to verify the effectiveness of the proposed technique. The CFD results indicate that the cooling temperature and the cooling surface roughness are the critical factors affecting the success of such technique used for cavitation suppression.

Thermal Deformation Simulation of Boron Steel Square Sheet in Fluid Cooling Process (사각판재 보론강을 사용한 유체냉각공정에서의 열변형 해석)

  • Suh, C.H.;Kwon, T.H.;Jeon, H.W.;Oh, S.K.;Park, C.D.;Choi, H.Y.;Moon, W.S.
    • Transactions of Materials Processing
    • /
    • v.26 no.1
    • /
    • pp.5-10
    • /
    • 2017
  • Fluid cooling is one of the manufacturing processes used to control mechanical properties, and is recently used for hot stamping of automobile parts. The formed part at room temperature is heated and then cooled rapidly using various fluids in order to obtain better mechanical properties. The formed part may undergo excessive thermal deformation during rapid cooling. In order to predict the thermal deformation during fluid cooling, a coupled simulation of different fields is needed. In this study, cooling simulation of boron steel square sheet was performed. Material properties for the simulation were calculated from JMatPro, and three convection heat transfer coefficients such as water, oil and air were obtained from the experiments. It was found that the thermal deformation increased when the difference of cooling rate of sheet face increased, and the thermal deformation increased when the thickness of sheet decreased.

Experimental study on the cooling characteristics of thermosyphon for the high power electronic components (고발열 전자부품 냉각용 써모사이폰의 냉각특성에 관한 연구)

  • 김광수;김원태;송규섭;이기백
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.137-146
    • /
    • 1998
  • The experimental study is concerned with two-phase closed thermosyphons, (i.e., wickless heat pipes) for the cooling of high power electronic components in telecommunication system. The thermosyphon which can deal with a high heat flux of up to $4.9W/cm^2$ is developed, and the cooling characteristics of thermosyphon is analyzed according to design parameters which are the types of and quantity of working fluid, number of pipes, wire insertion in pipe, inclination angle of thermosyphon, and cooling air velocity. Using water as working fluid is superior cooling performance compared to using acetone, and cooling performance is improved as the number of thermosyphon becomes larger, inserting wires in the pipes, and inclination of $30~60^{\circ}$.

  • PDF

An Experimental Study on Thermal Characteristics between Cooling Fluid and Ice Ball during Charging and Discharging Precesses (빙축 및 냉방열과정중 냉각유체와 Ice Ball사이의 열적 특성에 관한 실험적 연구)

  • 박경원;박이동;황영규;김윤제
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.193-205
    • /
    • 1996
  • This paper deals with experimental study on thermal characteristics that a cooling fluid is affected to ice ball as being measuring the temperature in storage tank and ice ball governing the rate of heat storage. Distributor was taken as inlet geometry factor. flow rate of cooling fluid which was a brine were 2, 4, and 6LPM, and 8, 10, and 12$^{\circ}C$ in the temperature difference for dynamic factors with respect to three ice ball types(103, 96, 76mm). In case of in flowing cooling fluid, since inertia force is suppressed by lower flow rate the amount of heat was transferred to ice ball by heat conduction high because density difference is high. And in case of larger ice ball, a long-term storage was available because reaching time at steady state is relatively long. consequently, smaller ice ball could be suitable to a short-term storage.

  • PDF

Thermal Fluid Flow Analysis for Temperature Characterization of Mold Transformer in Distribution Power System (배전용 몰드변압기의 온도특성 파악을 위한 열유동해석)

  • Kim, Ji-Ho;Lee, Jeong-Gun;Lee, Ki-Sik;Rhee, Wook;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.6-11
    • /
    • 2013
  • In this paper, the temperature characteristics of mold transformer for the distribution power system have been analyzed by using computational fluid dynamics(CFD). The model has been modeled by coil, cores, insulating materials and frames about 3MVA grade mold transformer and analyzed the temperature distribution of the structure with a heat fluid. The fluid, which is incompressible ideal gas, is analyzed as a turbulent flow phenomenon on the assumption that it is natural cooling of transformer cooling system. Through this study, by examining the temperature distribution and hot-spot of the structure field of the mold transformer, cooling design and temperature distribution information, which are demanded for designing are estimated.

Effects of the Lateral Ejection Angles and Distances of Double-Jet Holes on Flim Cooling Effectiveness (이중분사 막냉각 홀의 측면 분사각 및 홀 사이의 거리가 막냉각 효율에 미치는 영향)

  • Choi, Dae-Woong;Lee, Ki-Don;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.33-41
    • /
    • 2012
  • In the present work, a parametric study on double-jet film-cooling has been carried out to enhance the film-cooling effectiveness using three-dimensional Reynolds-averaged Navier-Stokes analysis. The shear stress transport turbulence model is used as the turbulence closure. The lateral ejection angles and the lateral and streamwise distance between the centers of the cooling holes are chosen as the geometric parameters. The spatially averaged film-cooling effectiveness averaged over an area of 8 hole diameters in width and 30 hole diameters in streamwise length is used to evaluate the performance of film-cooling. The parameter of the lateral distance has the largest impact on the film cooling effectiveness compared to the others. On the other hand, the parameter of streamwise distance gives the least influence on the film cooling effectiveness.

Study on the Design Concept of Impinging Jet Electronics Cooling by Using Axial Fan (축류 팬을 이용한 충돌제트 전자냉각 설계개념에 대한 연구)

  • Lee, Chan;Kil, Hyun-Gwon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.2
    • /
    • pp.24-30
    • /
    • 2009
  • Flow and noise analyses are conducted for examining a new design concept of impinging jet electronics cooling, and the analysis results are compared with conventional electronics cooling techniques. For the application of impinging jet electronics cooling method, the present study considers the air duct where air is supplied by axial fan and air flow from the duct is impinged vertically onto the electronic component heat source. Applying CFD simulation technique and fan noise model to the present cooling scheme, the cooling performance of the impinging jet as well as the operation condition and the noise characteristics of fan are investigated for various impinging jet nozzle conditions and fan models. Furthermore, the impinging jet electronics cooling analysis results are compared with the conventional parallel-flow cooling scheme to give the design concept and criteria of impinging jet cooling method.

A Numerical Study on the Conjugate Heat Transfer inside a High Speed Motor for a Small Radial Compressor (초소형 압축기용 초고속 전동기 내부의 복합 열전달 해석)

  • Kim, T. G.;Hur, N.;Jeong, S.;Jeon, S. B.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.1 s.10
    • /
    • pp.14-21
    • /
    • 2001
  • In a small centrifugal compressor system, a high-speed motor needs to be developed to drive impellers directly. Heat is generated by both electrical heating due to copper coil resistance and aerodynamic heating in the gap between the rotor and stator in a high-speed motor. Removal of the heat is essential to the design of such motors since most magnetic materials are brittle and can be easily fractured by the heat. In the present study the cooling flow fields and temperature distributions are analyzed by using computational fluid dynamics simulation for a high-speed motor which has air cooling system as well as water cooling system. In the analysis, a conjugate heat transfer problem is solved by considering both convective heat transfer in the cooling system and conduction heat transfer in solid parts. Based on design drawings of a motor, air cooling system and water cooling system are analyzed to obtain temperature field and thus to check the coiling system performance. Also the cooling performance are studied for various flow rates of cooling air and water at the inlets.

  • PDF