• 제목/요약/키워드: Cooling device

검색결과 460건 처리시간 0.031초

밀폐 형 전장 박스 온도 제어를 위한 히트 펌프 설계 (Design of Heat Pump for Temperature Control of Sealed Electric Box)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제19권2호
    • /
    • pp.110-114
    • /
    • 2020
  • In this paper, a heat pump using a Peltier device was developed for heat dissipation in a sealed electric box. The heat pump was designed with a cooling fin attached to both sides of the Peltier device, and a fan was mounted on the cooling fin on the hot side to increase the efficiency. The heat dissipation efficiency could be improved by directly connecting the electronic component having high heat to the cooling fin using a heat conducting wire. The fabricated heat pump was designed to operate only in the temperature range set by the temperature control system to improve the problem of high power consumption of the Peltier element.

태양광 시스템의 냉각장치 개발 (Development of Solar Concentrator Cooling System)

  • 이희준;차귀수
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4463-4468
    • /
    • 2014
  • 태양광 모듈 효율의 증가를 위해 렌즈나 반사판 등을 이용한 집광 시스템 개발이 활발하게 진행되고 있으며, 집광장치는 일반적으로 렌즈를 사용하거나 고집속비의 광학장치를 이용하여 태양광 추적형으로 설계하여 고집속화를 추구하고 있다. 그러나 집속비에 비례하여 열로 소산되는 에너지 밀도가 증가하므로, 고집속에 따른 태양전지 온도상승에 의한 태양전지 효율 저하를 방지하기 위해 집광장치의 냉각에 유의해야 한다. 본 논문에서는 이러한 여러 가지 제약 조건을 피하여, 저가격의 반사형 광학장치를 이용한 경제적인 저집광형 태양광 모듈 시스템을 연구 개발하였다. 일반모듈에 저집광장치를 사용하여 태양광 모듈의 발전효율을 증대 시키면서 집광으로 인해 발생하는 열을 냉각장치를 통해 방출하였다. 제안된 저집광형 냉각장치(MCS, Micro Cooling System)의 특징은 모세관력에 의한 자연 순환 방식으로서 외부 동력원이 불필요하며, 유체 상변환시의 잠열을 이용함으로써 고성능 냉각 구현이 가능하다. 117W 태양광 모듈에 반사판을 설치하고 냉각장치가 있는 모듈과 냉각장치가 없는 모듈을 비교 하였다. 냉각장치를 설치한 모듈에서의 발전량이 28% 증가하였다.

냉각 송풍장치를 이용한 기능성 농약방제복의 구성시안 제안에 관한 연구 (A Draft Proposal for Functional Pesticide Protection Clothing Using a Cooling Blower Unit)

  • 오영순;이경숙;채혜선;김경란
    • 한국지역사회생활과학회지
    • /
    • 제25권4호
    • /
    • pp.557-566
    • /
    • 2014
  • This study examines he trend in the development of protective clothing for pesticide spraying based on materials with domestic patents and proposes pesticide protection clothing using a cooling blower unit effective for reducing heat stress in pesticide spraying. There was a total of 54 domestic patents on protective clothing related to pesticide spraying, reflecting a sharp increase based on the increasing demand for protective clothing since 2000. Protective clothing with a lower level of heat stress as the core technology accounted for 35.2% of these patents, and recent years have witnessed the increased development of protective clothing supplying cold air to the interior of the clothing through a separate device. However, this may cause some inconvenience in the activity of farmers. Therefore, this study proposes a lightweight cooling blower unit that does not hinder the user's appearance and activity. In the cooling blower unit, contaminated air from outside is purified through a filter and cools down as it passes a cooling device with refrigerant in the copper pipe. This chilled air is supplied to the interior of the clothing through a bidirectional inhaling blower. The proposed protective clothing is an overall with raglan sleeves. Its chill injection site has an area where the most conspicuous change in temperature is selected, and at the back, there is a large pocket for a cooling blower unit.

해군 함정 VRTU의 과열방지를 위한 열전소자 냉각장치의 적용에 따른 기관실 및 VRTU 내부 열 유동특성 분석 (An Analysis of the Thermal Flow Characteristics in Engine-Room and VTRU in accordance with Application of Thermoelectric Device Cooling System to Prevent Overheating of the Korean Navy Ship VRTU)

  • 정영인
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.610-616
    • /
    • 2020
  • 본 연구에서는 대한민국 해군 함정의 하절기 운용 및 적도지병 파병 간 발생하고 있는 VRTU 과열로 인한 고온경보 발생과 장비정지 발생현상을 해결하기 위하여 해군 군수사령부 함정기술연구소와 공동연구를 수행하였다. 열전소자 냉각장치 설치에 따른 냉각효과를 확인하고, 전산 열 유동해석을 수행하여 VRTU 내부 열 유동특성을 분석하였다. 또 해석을 통해 기관실(디젤엔진룸) 내부의 온도분포를 살펴보고 VRTU 과열방지를 위한 최적의 설치위치를 알아보았다. 분석결과, 냉각장치를 설치함에 따라 VRTU 내부 평균 체적온도가 약 10 ℃ 감소하는 것을 확인하였으며 냉각장치에 설치된 Fan은 열 순환을 원활하게 하여 냉각효과를 높였다. 기관실 내부는 디젤엔진 상부에서 높은 온도분포를 나타냈고 통풍관 디퓨저 하부에서 가장 낮은 온도분포를 보였다. 열전소자 냉각장치는 높은 냉각성능을 나타내었으며, VRTU는 과열방지를 위하여 기관실의 통풍관 디퓨저 하부에 설치하는 것이 적절할 것으로 판단된다.

SMES용 kA급 초전도도체의 운전전류 특성 (Operating Current Characteristics of a kA Class Conductor for a SMES device)

  • 류경우;최병주;김해종;성기철
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2003
  • We have developed a small-sized superconducting magnetic energy storage (SMES) device, which provides electric power with high quality to sensitive electric loads. In large magnets such as the SMES magnets the stability, which is determined by several factors, e.g. conductors cooling condition and operating current, magnets winding structure, is a crucial problem. The effect of the cooling condition, the copper ratio, and the conductor's size upon the recovery currents was investigated experimentally. The results indicate that the recovery current characteristics of the strands vary considerably according to their insulation method. In the fully insulated strands with a low copper ratio, the recovery current densities range from 10 to 20 % of their engineering critical current densities. The recovery current density of the 30-conductor with a cooling channel is about a factor of 1.8 higher than that without a cooling channel.

  • PDF

Heat Dissipation of Sealed LED Light Fixtures Using Pulsating Heat Pipe Technology

  • Kim, Hyung-Tak;Park, Hae-Kyun;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.64-71
    • /
    • 2012
  • An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.

태양열을 이용한 무동력 냉난방 겸용장치의 특성 비교 연구 (Study on Characteristics Comparison of Unpowered Cooling and Heating Combined Device using Solar Heat)

  • 이재한;전태규;양영준
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.20-26
    • /
    • 2018
  • 지구온난화 현상이 세계적으로 점점 심각해지고 있으며 이에 대한 대책으로 에너지 원천의 다양화, 에너지 절감 기술 등이 필요하다. 본 연구에서는 태양열을 이용한 무동력 냉난방 겸용장치를 실현하기 위하여 태양열 집열기 흡수판의 재질변화, 무동력과 최소의 동력을 사용하였을 때의 특성을 비교하고자 하였다. 그 결과로서 하절기에 태양열 집열장치를 부착한 경우는 부착하지 않은 경우보다 실내온도가 약 $1^{\circ}C$ 낮았으며, 하절기에 냉원저장조가 없는 상태에서 태양열 집열장치에 의한 냉방효과는 적었다. 그러나 동절기에는 실내온도가 약 $3^{\circ}C$ 높았으며 무동력에 의한 난방효과의 가능성이 있었다. 간접적인 측정방법에 의해, Cu 재질의 태양열 집열장치의 성능은 Al 재질과 비교하여 약 2배 높았다.

전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구 (A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System)

  • 강창수;강기성
    • 전자공학회논문지 IE
    • /
    • 제46권4호
    • /
    • pp.25-30
    • /
    • 2009
  • 용광로는 외피 부분에 내부 내화물의 온도를 낮추기 위하여 냉각수를 공급하는 냉각판 또는 스테이브를 사용하고 있다. 주변 조업 조건의 열악으로 냉각수를 공급하는 배관의 부식으로 냉각수가 내화물에 침투하여 내화물의 수명을 떨어뜨리고, 노황을 악화시키는 원인이 되고 있다. 이에 본 연구는 용광로 냉각설비장치에 이상 현상이 발생하였을 때 위치를 정확히 확인함에 따라 신속하게 누수된 부위를 파악하여 대처할 수 있는 기능을 갖춘 냉각관 누수 자동감지장치를 개발하였다. 주된 연구는 전자제어 장치인 마이크로프로세서를 응용한 전자변 제어장치를 이용하여 냉각설비의 파손으로 발생되는 누수현상으로 인한 고열과 분진 일산화탄소 등의 산출로 작업환경의 재해를 자동방지 하고자 하였으며, 작업환경이 친환경적이며 작업의 가치를 재창출할 수 있는 방법들이 연구되고 있다. 용광로 분위기의 일산화탄소 자동 감지장치와 그에 따른 출력신호를 자동 전송하는 무선중계기 장치를 개발함으로 용광로 냉각설비 장치의 분위기 작업환경을 수동방식에서 무인자동화방식으로 개선하였다.