• Title/Summary/Keyword: Cooling Efficiency

Search Result 1,126, Processing Time 0.026 seconds

Analysis and Efficiency Control of Linear Compressor System for Refrigerator Driven by PWM Inverter (PWM인버터로 구동되는 냉장고용 선형압축기시스템의 특성해석 및 효율제어)

  • Son, Jang-Kyung;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1544-1549
    • /
    • 2013
  • Recently, the linear compressors with the free piston driven by the linear motor have widely attention in the cooling apparatus such as a refrigerator due to high efficiency. The method of using triacs as a linear motor drive is not satisfactory to improve the efficiency of the linear compressor. In this paper, the performance of the linear compressor using a PWM inverter such as the efficiency is investigated with the variations of both mechanical resonant frequency and electrical resonant frequency. The control loop for controlling both the piston stroke and efficiency is suggested. Through simulation and experimental studies, the performance of both the stroke and angle controls for improving the efficiency of the linear compressor is verified.

Performance analysis of a cooling system with refrigerant in a marine absorption refrigerator (선박용 흡수식 냉동기의 냉매적용 냉각 시스템 성능 분석)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.282-287
    • /
    • 2016
  • Recently in order to protect the ocean environment and to reduce energy consumption, shipbuilders have been developing highly economized ships. This research analyzed the possibility of adopting the onshore absorption refrigerator to offshore ships having a cooling system with refrigerant by using the waiste heat of the engine jacket cooling water instead of compression refrigerators. The results showed that R236fa could be a suitable medium for absorbing the heat of the absorber and condenser in an absorption refrigerator. The cooling system using R236fa achieved a high COP of 0.798, which is 15% and 5% higher than an air cooling system with a cooling tower and a water cooling system with a heat exchanger, respectively. The cooling system with R236fa achieved high efficiency with a 25% reduction in flow rate of LiBr solution and only 15.7% flow rate of cooling medium as compared to the water cooling system. The heating of sea water by the engine jacket water flowing out from the generator can prevent the crystallization of LiBr solution due to the low temperature of sea water.

Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position (필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석)

  • Park, Jee Min;Moon, Joo Hyun;Lee, Hyung Ju;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.69-76
    • /
    • 2018
  • The present study analyzed the effect of film hole position of 45 degree ribbed cooling channel on film cooling performance of gas turbine blades. We also investigated the influence of the ribs under the fixed blowing ratio. Three-dimensional numerical model was constructed and extensive simulation was conducted using the commercial code (Fluent ver. 17.0) under steady-state condition. Base on the simulation results, We investigated the cooling effectiveness, flow velocity, streamline, and pressure coefficient. Moreover, We analyzed the effect of cooling hole position on ejection of the secondary flow caused by the rib structure. From the results, It was found that internal flow of the cooling channel forms a vortex pair in the counterclockwise from the top side, and clockwise from the bottom side. For the channels with ribs, the vortex flow generated by the ribs caused a higher pressure difference near the hole outlet, resulting in at least 12% higher cooling effectiveness than the channel without ribs. Additionally, when the hole is located on the left side of the ribbed channel (Rib-Left), it can be found that the secondary flow generated by the ribs hits against wall surface near the hole to form a flow in the direction of the hole inclination angle. Therefore, It is considered that the region where the cooling gas discharged to the blade surface stays in the main flow boundary layer is wider than the other cases. In this case, The largest pressure coefficient difference was observed near the outlet of the hole, and as a result, the discharge of the cooling gas was accelerated and the cooling efficiency was slightly increased.

Effect of Improved Cooling System on Reproduction and Lactation in Dairy Cows under Tropical Conditions

  • Suadsong, S.;Suwimonteerabutr, J.;Virakul, P.;Chanpongsang, S.;Kunavongkrit, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.4
    • /
    • pp.555-560
    • /
    • 2008
  • The effects of utilizing evaporative cooling system equipped with tunnel ventilation on postpartum ovarian activities, energy balance and milk production of early lactating dairy cows under hot and humid climates were studied from parturition to 22 wk postpartum. Thirty-four crossbred Holstein-Friesian (93.75% HF$\times$.25% Bos indicus) primiparous cows were randomly assigned to one of two groups. Cooled cows (n = 17; treatment) were housed in the tunnel ventilated barn equipped with evaporative cooling system and uncooled (n = 17; control) were housed in the naturally ventilated barn without supplemental cooling system. Cooled cows had greater (p<0.05) dry matter intake and milk production than uncooled cows. Days to the energy balance (EB) nadir did not differ between groups. However, days to equilibrium EB for uncooled cows was longer (p<0.05) than for cooled cows. There was no significant difference in postpartum anovular condition between cooled and uncooled cows. The interval from parturition to first postpartum ovulation did not differ between groups ($31.4{\pm}4.3$ and $26.1{\pm}3.6$ day, respectively). These results suggest that the evaporative cooling and tunnel ventilation has the potential to decrease the severity of heat stress and improve both milk production and metabolic efficiency during early lactation without affecting reproductive function in dairy cows under hot and humid climates.

Experimental Study on the Cooling and Heating Characteristics of System A/C Applying the Digital Scroll Compressor (디지털 스크롤 압축기를 적용한 시스템 에어컨의 냉난방특성에 대한 실험적 연구)

  • Jeon, Yong-Ho;Kim, Dae-Hoon;Kwon, Young-Chul;Jang, Geun-Sun;Lee, Yoon-Soo;Moon, Je-Nyung;Yoon, Baek;Hong, Ju-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.454-460
    • /
    • 2003
  • In order to investigate the cooling and heating characteristics of a variable-capacity system A/C applying a digital scroll compressor, the cooling and heating capacities and COP are measured by the psychrometric calorimeter. The capacity of the system is controlled by the digital scroll compressor, which is operated by controling PWM valve and the loading vs. unloading time. In the case of unloading compared that of loading, the consumption power of the compressor is about 11% and the capacity variation of the system A/C is within about 1%. When the system A/C is operated under the cooling and heating standard conditions, COP is nearly uniform but cooling capacity and heating capacity increase at minimum, rated and maximum modes. The system A/C applying the digital scroll compressor is effective for the range with high load or the width of large load variation. When the auxiliary heater is on, at the cold region, the system A/C produces the excellent heating capacity.

Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment (공동주택에서 지열 냉난방 시스템 적용시 경제성 분석)

  • Park, Yongboo;Park, Jongbae;Lim, Haesik;Baek, Sungkoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.11-18
    • /
    • 2007
  • This paper studied the economical efficiency of ground source heat pump system under various conditions in apartments which have important effects on the housing market. And this study analysed the initial cost increase, saved managing cost and recovery time of initial cost. Analysis result showed as time of heating-cooling and water heating increases, the amount of saved managing cost increased much than the initial construction cost, so recovery time shortened. And as the net area of apartment increases, the recovery time increased. The study of the relation between the installation type and recovery time of initial construction cost showed when heat-cooling system adapted ground source heat and water heating system adapted waste heat, the initial construction cost was recovered most quickly. When Ground Source Heating system was used for the heating-cooling and water heating system, ground source heating system was used for the heating-cooling and waste heat used for water heating, and ground source heating system was used for the heating-cooling and LNG used for water heating, the construction cost increased 72,000, 66,900 and 62,300 won each per $m^2$ compared to the current system (package air-conditioner, heating and water heating using LNG).

  • PDF

Application of ozone treatment in cooling water systems for energy and chemical conservation

  • Ataei, Abtin;Mirsaeed, Morteza Ghazi;Choi, Jun-Ki;Lashkarboluki, Reza
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.155-172
    • /
    • 2015
  • In this study, a complete set of recirculating cooling water system and the required instruments were built in a semi-industrial-scale and a 50 g/h ozone generation plant and a chlorine system were designed for cooling water treatment. Both chlorination and ozonation treatment methods were studied and the results were analyzed during two 45-days periods. The concentrations of ozone and chlorine in recirculating water were constant at 0.1 mg/lit and 0.6 mg/lit, respectively. In ozone treatment, by increasing the concentration cycle to 33%, the total water consumption decreased by 26% while 11.5% higher energy efficiency achieved thanks to a better elimination of bio-films. In case of Carbon Steel, the corrosion rate reached to 0.012 mm/yr and 0.025 mm/yr for the ozonation and chlorination processes, respectively. Furthermore, consumptions of the anti-corrosion and anti-sedimentation materials in the ozone cooling water treatment were reduced about 60% without using any oxidant and non-oxidant biocides. No significant changes in sediment load were seen in ozonation compared to chlorination. The Chemical Oxygen Demand of the blow-down in ozonation method decreased to one-sixth of that in the chlorination method. Moreover, the soluble iron and water turbidity in the ozonation method were reduced by 97.5% and 70%, respectively. Although no anaerobic bacteria were seen in the cooling water at the proper concentration range of ozone and chlorine, the aerobic bacteria in chlorine and ozone treatment methods were 900 and 200 CFU/ml, respectively. The results showed that the payback time for the ozone treatment is about 2.6 years.

Development of a New Air Cooling System Utilizing the Stirling Engine for Preventing Solar Cell from Overheating (태양광 모듈의 과열 방지용 공랭형 스털링기관 냉각 시스템 개발)

  • Kim, Hyoungeun;Park, Chanwoo;Chu, Jinkyung;Keum, Dongyeop;Park, Silro;Kim, Jeongmin;Kim, Daejin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.57-63
    • /
    • 2014
  • In this paper new air-cooling system utilizing Stirling engine was proposed for improving efficiency in solar photovoltaic power generation. The solar cell plate was equipped with semi-circular channel for air flow on the backside. Beta-type Stirling engine was installed on the plate and its flywheel was connected to a motor fan by a transmission belt. A forced convective air flow for heat radiation was generated by the operation of the self-starting Stirling engine. The performance tests for power generation of solar cell with or without the proposed air-cooling system were conducted under halogen lamp. From the experimental results, it was found that decline in output voltage of the solar cell with proposed cooling system was 25% less than that of the solar cell without cooling system.

EFFECTS OF DIFFERENT COOLING TECHNIQUES ON DRAUGHT CAPACITY OF BUFFALO

  • Bunyavejchewin, P.;Kaewsomprasong, K.;Chotemethepirom, S.;Tanta-ngai, B.;Tajima, A.;Chikamune, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.2
    • /
    • pp.131-136
    • /
    • 1991
  • Four male swamp buffaloes weighing $460.5{\pm}44.6kg$ were used to study the effects of different cooling techniques on draught capacity. Each animal carted an 882 kg load on the same asphalt road for one hour during four different time periods: 9:00-10:00 A.M., 10:30-11:30 A.M., 2:00-3:00 P.M. and 3:30-4:30 P.M. Simultaneously, all animals were subjected to five different treatments on five days of similar environmental conditions. In Treatment 1, animals were put stationary in a field and did no work; in Treatment 2, animals were worked without any cooling method; in Treatment 3, fifteen-minute wallow was allowed to animals prior to working; in Treatment 4, animals were covered with wetted jute bags while working, and in Treatment 5, two buckets of water were poured over the buffaloes' trunks just prior to working. The experiment was conducted from April to July 1989, when the weather was very hot. It was found that cooling methods and working times did not affect the draught efficiency of buffaloes during the one hour, but did affect physiological traits. The work load had a larger partial effect on physiological responses of buffalo other than respiration rate than did climatic variables except on the respiration rate of the buffaloes. One cooling technique that seemed to slow the increase of body temperature while working was covering the buffalo's back with wetted jute bags. Animals working at different times had significant differences in the increase of physiological traits except pulse rate.

Actual State of Practical Use and Cooling Effect of Evaporative Cooling Systems (증발냉각시스템의 활용실태 및 냉방효과)

  • 김문기;유인호;김기성
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.281-287
    • /
    • 1999
  • In order to take a good look at effectiveness of cooling of Fog system and Pad-Fan system, we chose 49 farm households which were installed evaporative cooling system and 2 farm households which were installed Pad-Fan system and Fog system for a test. We execute the test on 29 households out of 49.6 households, which were installed Pad-Fan system, were able to use; however, 6 household out of 9 which were installed Fog system couldn't use it. The main reason was the clogged on nozzle. The cooling efficiency on Pad-Fan system was 77.4%, but it was very poor on Fog system. Since there are many problems on Fog system, we need more research on size of fog, the location of nozzle, control of Fog systems.

  • PDF