• 제목/요약/키워드: Cooling Cycle

검색결과 641건 처리시간 0.024초

운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교 (Cooling and Heating Performances of a CO2 Heat Pump with the Variations of Operating Conditions)

  • 조홍현;백창현;이응찬;강훈;김용찬
    • 대한기계학회논문집B
    • /
    • 제32권6호
    • /
    • pp.454-462
    • /
    • 2008
  • Since operating conditions are significantly different for heating and cooling mode operations in a $CO_2$ heat pump system, it is difficult to optimize the performance of the $CO_2$ cycle. In addition, the performance of a $CO_2$ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed $CO_2$ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.

CO2 냉각모듈을 적용한 고곡률 성형품의 사출금형 급속냉각 (Rapid cooling of injection mold for high-curvature parts using CO2 cooling module)

  • 이세호;이호상
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.67-74
    • /
    • 2022
  • Injection molding is a cyclic process comprising of cooling phase as the largest part of this cycle. Providing efficient cooling in lesser cycle times is of significant importance in the molding industry. Recently, lots of researches have been done for rapid cooling of a hot-spot area using CO2 in injection molding. The CO2 flows under high pressure through small, flexible capillary tubes to the point of use, where it expands to create a snow and gas mixture at a temperature of -79℃. The gaseous CO2 removes heat from the mold and releases it into the atmosphere. In this paper, a CO2 cooling module was applied to an injection mold in order to cool a large area cavity uniformly and quickly, and the cooling performance of the injection mold was investigated. The product was a high-curvature molded part with a molding area of 300x100mm. Heat cartridges were installed in a stationary mold, and CO2 cooling module was inserted inside a movable mold. Through structural analysis, it was confirmed that the maximum deformation of mold with CO2 cooling module was 0.09mm. A CO2 feed system with a heat exchanger was used for cooling experiments. The CO2 was injected into the holes on both sides of the supply pipe of the cooling module and discharged through hexagon blocks to cool the mold. It took 5.8 seconds to cool the mold from an average temperature of 140℃ to 70℃. Through the experiment using CO2 cooling module, it was found that a cooling rate of up to 12.98℃/s and an average of 10.18℃/s could be achieved.

하수열을 이용한 냉난방시스템에 관한 연구 (Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle)

  • 이용화;신현준;윤희철;박현건
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.

인터쿨러와 공랭식 응축기를 동시에 사용하는 냉방-냉동 겸용 캐스케이드 사이클에 대한 연구 (A Study on the Cascade Hybrid Cooling/Refrigeration Cycle Equipped With Intercooler and Air-Cooled Condenser in Series)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제20권7호
    • /
    • pp.353-362
    • /
    • 2019
  • 그간 캐스케이드 냉동 시스템에 대해서 열역학적 해석은 다수 수행되었으나 증발기, 응축기, 인터쿨러 등 부품 해석을 통한 시스템 평가는 미진한 상태이다. 본 연구에서는 냉방 및 냉동 열교환기가 별도로 장착되어 있고 하부 사이클에 공랭식 응축기와 인터쿨러가 직렬로 연결되어 있는 캐스케이드 냉동 사이클에 대해 성능 해석을 수행하였다. 우선 증발기, 응축기, 인터쿨러 등 요소부품에 대해 모델링을 수행하고 R-410A를 사용하는 냉방 능력 8 kW, 냉동 능력 15 kW의 캐스케이드 냉동 사이클의 요소 부품의 - 상부 응축기, 하부 응축기, 냉방 증발기, 냉동 증발기, 인터쿨러, 압축기, 전자팽창변 - 설계를 수행하였다. 설계 사양에 대하여 외기 온도를 $26^{\circ}C$에서 $38^{\circ}C$로 변화시키며 해석을 수행한 결과 냉각 열량은 하부 증발기에서는 거의 일정하고 상부 증발기에서는 9% 감소, 인터쿨러에서는 63% 증가하였다. 한편 COP는 외기 온도의 증가에 따라 감소하였다. 인터쿨러가 작동하지 않는 사이클 대비 인터쿨러 사이클이 COP 측면에서 우위를 보였다. 또한 상부 응축기의 크기를 당초 설계치의 2배 증가시키면 하부 증발기 열량은 변함이 없는 반면 상부 증발기 열량은 4% 증가하였다. 한편 상부 응축기의 크기 증가에 따라 상부 사이클의 COP는 증가하는 반면 하부 사이클의 COP는 큰 변화가 없다. 또한 하부 응축기 크기를 2.8배 증가시키면 상하부 증발기의 열량 변화는 거의 없고 인터쿨러의 열량만이 8% 감소하였다. 아울러 하부 사이클의 COP는 응축기의 크기가 증가함에 따라 다소 증가하였으나 상부 사이클의 경우는 그 변화가 미미하였다.

가스터빈 복합발전의 기동특성을 고려한 열거래 기반 지역 냉난방 시스템의 최적 운영 모델 (Optimal Operation Model of Heat Trade based District Heating and Cooling System Considering Start-up Characteristic of Combined Cycle Generation)

  • 김종우;이지혜;김학만
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1610-1616
    • /
    • 2013
  • Recently, district heating and cooling (DHC) systems based on combined cycle generation (CCG) providers are increasing in Korea. Since characteristics of combined heat and power (CHP) generators and heat demands of providers, heat trading between DHC providers based on the economic viewpoint is required; the heat trading has been doing. In this paper, a mathematical model for optimal operation based on heat trading between DHC providers is proposed. Especially, start-up characteristic of CCG is included. The operation model is established by mixed integer linear programming (MILP).

이산화탄소를 적용한 주거용 냉난방 겸용 열펌프 시스템의 시뮬레이션 (Simulation on a Residential Heat Pump System Using $CO_2$)

  • 조홍현;이무연;김용찬
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.987-995
    • /
    • 2003
  • The performance of a residential heating and cooling system with $CO_2$ is predicted by using a cycle simulation model. The simulations are conducted by varying design parameters and operating conditions. The efficiency of the transcritical cycle can be improved by utilizing the advantages in heat transfer characteristics of $CO_2$ and developing microchannel indoor and outdoor heat exchangers. For the designed system of this study, the predicted COP of the heat pump system is approximately 3.5 in the heating mode and 3.0 in the cooling mode. The predicted optimal discharge pressure for the heat pump system is approximately 11 MPa in the heating mode and 9 MPa in the cooling mode.

HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구 (Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling)

  • 박재홍;권용하;김영수;박성출
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

하천수 열원 이용 열펌프 시스템의 LCC 분석 (LCC Analysis of a Heat Pump System Using River Water)

  • 한상수;박차식;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1424-1428
    • /
    • 2009
  • The performance of a heat pump using river water as a heat source was compared with that of a conventional air-conditioner for cooling and a boiler system for heating. The heat pump system using river water considered the 1-stage cycle for cooling and the 2-stage cycle for heating. The COPs of the river water source heat pump were $0.5{\sim}1.1$ higher than those of the conventional system in the cooling season. The LCC of the river water source heat pump system was lower 13.5% and 32.4% than that of the conventional system I and II. In addition, when the initial cost ratios of the river water source heat pump system to the conventional system I and II were less than 1.2 and 1.4, respectively, an acceptable payback was found to be less than 5 years.

  • PDF

CAP 금형의 사출성형공정에 대한 해석 (Analysis of Injection Molding Process for CAP Mold)

  • 신장순;오상륜;허영무;윤길상;김유진
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.23-27
    • /
    • 2005
  • Generally, when the injection molds are made in advanced nations, the improvement of a quality and production rate is obtained by using CAE. In this paper, the methodology which is possible to reduce the cycle time of injection molding process is studies by using the cooling analysis with CAE(Moldmax). In case of changing the cooling system design with the analysis result of CAE, the manimum reduction of the cycle time runs into 30 percent. Finally, the average reduction of the cycle time is 17.8 percent.

  • PDF

고효율 냉동 컨테이너의 냉각 및 제상 실험 (Experimental Study of a High Efficiency Transport Refrigeration Container under Cooling and Defrosting Conditions)

  • 문제철;;최광일;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.277-281
    • /
    • 2008
  • This paper presents the development of a high efficiency transport refrigeration system for sliced-raw fish transportation. The refrigeration system is equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system). System performance and container operating conditions are analyzed during experimental investigation on a $3,225{\times}1,740{\times}1,640\;mm$ full-scale refrigerated container under cooling and defrosting conditions. The prototype system indicates better performance in terms of shorter cooling-down time, shorter defrost time and smaller fluctuations of refrigerated container's temperature.

  • PDF