• Title/Summary/Keyword: Cooling Age

Search Result 109, Processing Time 0.028 seconds

CHIME Zircon Age of the Gamaksan Alkaline Meta-Granitoid in the Northwestern Margin of the Gyeonggi Massif, Korea, and its Tectonic Implications (경기육괴 북서 연변부 감악산 알칼리 변성화강질암의 CHIME 저어콘 연대와 지체구조적 의의)

  • Cho, Deung-Lyong;Lee, Seung-Ryeol;Suzuki, Kazuhiro
    • The Journal of the Petrological Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.180-188
    • /
    • 2007
  • We carried on CHIME zircon age dating for the Gamaksan alkaline meta-granitoid (GAM) from the northwestern margin of the Gyeonggi massif, and obtained a timing of regional metamorphism at $247{\pm}14Ma$ (n=103, MSWD=0.92). The age is compatible with Permo-Triassic regional metamorphic ages from the Imjingang Belt which has been regarded as possible eastward extension of Triassic collisional belt in China. Considering an extensional ductile shearing of the Gyeonggi (Kyonggi) Shear Zone which deformed GAM occurred at 226 Ma with temperature condition about $500^{\circ}C$ (Kim et al., 2000), and the Late Triassic to Early Jurassic Daedong Group unconformably overlies on top of the ductile shear zone, cooling rate of GAM over the period can be estimated as $18{\sim}10^{\circ}C/Ma$. Since new zircon begin to pow at temperature higher than upper-amphibolite facies condition (${\sim}700^{\circ}C$), cooling rate of GAM from peak metamorphism (247 Ma) to deposition of the Daedong G.oup (${\sim}$Early Jurassic) would be higher than $10^{\circ}C/Ma$. Such rapid cooling rate is compatible with that reported from exhumation stage of the Dabie-Sulu Belt, and supports an idea that the Gyeonngi massif is a part of Permo-Triassic orogenic belt in East Asia.

Cooling and Thermal Histories of Cretaceous-Paleogene Granites from Different Fault-bounded Blocks, SE Korean Peninsula: Fission-track Thermochronological Evidences (한반도 동남부의 주단층대에 의해 구분된 지질블록별 백악기-고제3기 화강암의 차별적 냉각-지열 이력: 피션트랙 열연대학적 증거)

  • Shin, Seong-Cheon
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.335-365
    • /
    • 2012
  • Fission-track (FT) thermochronological records from SE Korean Cretaceous-Paleogene granitic plutons in different fault-bounded blocks reveal contrasting cooling and later thermal histories. Overall cooling patterns are represented by a monotonous (J-shaped) curve in most plutons except some Cretaceous granites retaining a complicated (N-shaped) path due to post-reset re-cooling. Discriminative cooling rates over different temperature ranges can be explained for individual plutons with respect to relative pluton sizes, differences in initial heat loss depending on country rocks, and the presence and proximity of later igneous activity. Even within a single batholith, cooling times for different isotherms were roughly contemporaneous with respect to positions. Insignificant deviations in cooling ages from two different plutons in succession across the Yangsan fault may suggest their contemporaneity before major horizontal fault movement. The extent of later thermal rise recorded locally along the Yangsan and Dongnae fault zones were reached the Apatite Partial Stability Zone ($70-125^{\circ}C$), but did not exceed $200^{\circ}C$. Thermal alteration from fractured zones in the Yangsan-Ulsan fault junction may suggest a thermal reset above $290^{\circ}C$ resulting a complete reset in FT sphene age (31 Ma), caused by a tectonic subsidence in Early Oligocene. A consistency in FT zircon/apatite ages (24 Ma) may imply a sudden rapid cooling over $200-105^{\circ}C$, plausibly related to the abrupt tectonic uplift of the Pohang-Gampo Block including the fault junction in Late Oligocene. A remarkable trend of lower cooling ages for $300-200-100^{\circ}C$ isotherms (i.e., 19% for FT sphene and K-Ar biotite; 20% for FT zircon; 27% for FT apatite) from the east of the Ulsan fault (Pohang-Gampo Block) comparing to the west of the fault may be attributed to retarded cooling times from the Paleogene granites and also reflected by their partially-reduced apatite ages due to later thermal effects.

Early-age thermal analysis and strain monitoring of massive concrete structures

  • Geng, Yan;Li, Xiongyan;Xue, Suduo;Li, Jinguang;Song, Yanjie
    • Computers and Concrete
    • /
    • v.21 no.3
    • /
    • pp.279-289
    • /
    • 2018
  • Hydration heat and thermal induced cracking have always been a fatal problem for massive concrete structures. In order to study a massive reinforced concrete wall of a storage tank for liquefied natural gas (LNG) during its construction, two mock-ups of $0.8m{\times}0.8m{\times}0.8m$ without and with metal corrugated pipes were designed based on the actual wall construction plan. Temperature distribution and strain development of both mock-ups were measured and compared inside and on the surface of them. Meanwhile, time-dependent thermal and mechanical properties of the concrete were tested standardly and introduced into the finite-element (FE) software with a proposed hydration degree model. According to the comparison results, the FE simulation of temperature field agreed well with the measured data. Besides, the maximum temperature rise was slightly higher and the shrinkage was generally larger in the mock-up without pipes, indicating that corrugated pipes could reduce concrete temperature and decrease shrinkage of surrounding concrete. In addition, the cooling rate decreased approximately linearly with the reduction of heat transfer coefficient h, implying that a target cooling curve can be achieved by calculating a desired coefficient h. Moreover, the maximum cooling rate did not necessarily decrease with the extension of demoulding time. It is better to remove the formwork at least after 116 hours after concrete casting, which promises lower risk of thermal cracking of early-age concrete.

Open Heart Surgery During The First 12 Months Of Life (유아기의 개심술14례 보고)

  • Ahn, Kyuk;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.14 no.4
    • /
    • pp.381-387
    • /
    • 1981
  • Fourteen Infants with congenital cardiac anomalies underwent primary surgical Intervention within the first 12 months of life. There were eight patients with ventricular septal defect, two with total anomalous pulmonary venous return [TAPVR], and the remainders with tetralogy of Fallot, transposition of great arteries [d-TGA], Taussing-Bing malformation, and coronary A-V fistula. The age of the patients ranged from 5 to 12 months, with a mean age of 9.9 months. The mean weight was 6.7 Kg [3.8 to 9.5 KS]. Congestive heart failure persisting despite intensive medical treatment was present In 8 patients [56%], and was the most common indication for operation. Early operation was necessary in 5 of these patients [35%], because of failure to thrive and recurrent pulmonary infection. In one patient with TOF, frequent hypoxic spell prompted the necessity for early operation. In cases of VSD, TAP. VR, TOF, and coronary A-V fistula, Intracardiac repair was done with conventional cardiopulmonary bypass, chemical cold cardioplegia, and topical myocardial cooling. Deep hypothermic circulatory arrest with surface induced cooling, followed by core cooling and core rewarming, was employed .for better exposure in the cases of d-TGA and Taussing-Bing malformation. The results were however, not satisfactory. The overall mortality was 28 per cent. There were no deaths in the eight patients with VSD. The one with coronary A-V fistula survived. The other 5 cases all expired either on the table or immediately after operation. The non-fatal post-operative complications included low cardiac output, respiratory insufficiency, bleeding, and temporary A-V block. The causes of death were prolonged circulatory arrest time in d-TGA, complete A-V block and low cardiac output in TOF and Taussing-Bing malformation and prolonged bypass time and Inadequate correction in TAPVR.

  • PDF

Open Heart Correction Of Ebstein`S Anomaly: A Report Of 8 Cases (Ebstein`s 심기형의 개심수술 8예)

  • 김삼현
    • Journal of Chest Surgery
    • /
    • v.14 no.4
    • /
    • pp.388-398
    • /
    • 1981
  • Fourteen Infants with congenital cardiac anomalies underwent primary surgical Intervention within the first 12 months of life. There were eight patients with ventricular septal defect, two with total anomalous pulmonary venous return [TAPVR], and the remainders with tetralogy of Fallot, transposition of great arteries [d-TGA], Taussing-Bing malformation, and coronary A-V fistula. The age of the patients ranged from 5 to 12 months, with a mean age of 9.9 months. The mean weight was 6.7 Kg [3.8 to 9.5 KS]. Congestive heart failure persisting despite intensive medical treatment was present In 8 patients [56%], and was the most common indication for operation. Early operation was necessary in 5 of these patients [35%], because of failure to thrive and recurrent pulmonary infection. In one patient with TOF, frequent hypoxic spell prompted the necessity for early operation. In cases of VSD, TAP. VR, TOF, and coronary A-V fistula, Intracardiac repair was done with conventional cardiopulmonary bypass, chemical cold cardioplegia, and topical myocardial cooling. Deep hypothermic circulatory arrest with surface induced cooling, followed by core cooling and core rewarming, was employed .for better exposure in the cases of d-TGA and Taussing-Bing malformation. The results were however, not satisfactory. The overall mortality was 28 per cent. There were no deaths in the eight patients with VSD. The one with coronary A-V fistula survived. The other 5 cases all expired either on the table or immediately after operation. The non-fatal post-operative complications included low cardiac output, respiratory insufficiency, bleeding, and temporary A-V block. The causes of death were prolonged circulatory arrest time in d-TGA, complete A-V block and low cardiac output in TOF and Taussing-Bing malformation and prolonged bypass time and Inadequate correction in TAPVR.

  • PDF

A Study on Ventilation Effectiveness in the Non-isothermal Supply using Mixing and Displacement Ventilation Systems (비등온 급기조건에서 환기방식에 따른 환기효율 특성에 관한 연구)

  • 이재근;강태욱;윤석구;구재현;한정균;조민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.739-745
    • /
    • 2001
  • The objective of this research is to analyze the ventilation effectiveness in the non-isothermal air supply using mixing and displacement ventilation systems for indoor air quality control and management. In this study, a ventilation effectiveness is evaluated in a simplified model chamber using a tracer gas technique of $CO^2$ gas injected into a supply duct as a function of ventilation rates, supply/extract sites and cooling/heating air supply. The ventilation effectiveness decreased with increasing ventilation rate on the cooling and heating conditions. And the ventilation effectiveness of case 3 (down supply and upper extract) was better thant that of case 1(upper supply and upper extract) and case 2(upper supply and down extract) with the cooling supply conditions. but for the heating supply air conditions, the ventilation effectiveness of case 2 was better than that of case 3 and case 1.

  • PDF

The milli-arcsecond scale radio properties of central AGNs in cool-core and non cool-core clusters

  • Baek, Junhyun;Chung, Aeree;Tremou, Evangelia;Sohn, Bongwon;Jung, Taehyun;Ro, Hyunwook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.68.4-69
    • /
    • 2016
  • We report preliminary results of KaVA observations of central galaxies in cool-core and non cool-core clusters. The main goal is to study how cooling environments of galaxy clusters affect the central AGN activities especially at its innermost region. For KaVA observations, 7 radio bright AGNs have been selected from the extended Highest Flux Galaxy Cluster Sample (eHIFLUGCS; the X-ray flux limited & all sky galaxy cluster catalog) with various cooling timescales. In our previous KVN study, we have found that most AGNs in the cool-core clusters show the hint of pc-scale jet-like features while the ones in the non cool-core clusters do not. Using the KaVA 22/43 GHz data of a much higher resolution than the KVN resolution, we have investigated detailed pc-scale jet properties such as physical size, morphology, and radiative age. Based on the KaVA data, we discuss the effect of cluster cooling environment on the evolution of AGNs in the cluster center.

  • PDF

Clinical experience of open heart surgery: 50 cases (개심술 치험 50례)

  • 정황규
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.65-74
    • /
    • 1983
  • Fifty cases of open heart surgery were done in the Department of Thoracic and Cardiovascular Surgery, Busan National University Hospital during 16 months from July, 1981 to October, 1982. The clinical data were analyzed and summerized as follows. 1. There were 34 cases (68%) of congenital anomalies and 16 cases (32%) of acquired heart diseases. Among the congenital cases, 27 were acyanotic and 7 were cyanotic. All of the acquired heat diseases, 16 cases were valvular diseases and they had valvular replacement surgery. 2. The age distribution of the congenital anomalies ranged from 6 to 27 years with mean age of 14.2 years, and the acquired heart diseases from 18 to 44 years mean age of 27.5 years. The difference of sex distribution was no significance. 3. The clinical minifestations in acyanotic congenital anomalies were exertional dyspnea (81.5%), recurrent respiratory infection (55.6%) and palpitation (22.2%), and in cyanotic congenital anomalies were exertional dyspnea (100%), syncope(57.1%) and growth retardation(57.1%), and in acquired heart diseases were dyspnea(100%), edema (62.5%) and general weakness (62.5%) 4. During the cardiopulmonary bypass, mild to moderate core cooling was performed and added topical cooling for more accurate myocardial preservation. 5. Two kinds of cardioplegic solution used in our institute were Bretschneider solution for the first 7 cases and mixed Harmann's solution 1 L with glucose 5gm, potassium chloride 26 mEq and sodium bicarbonate 24 mEq, making 376 mosmol/L and pH 8.3 at $25^{\circ}C$, for the rest 43 cases. 6. Various kinds of postoperative complications occurred in 14 cases (28%) and showed overall mortality 12%. The mortality along with each disease was 7.4% in congenital acyanotic cases, 42.9% in congenital cyanotic cases and 6.3% in acquired valvular diseases. 7. Pre-and postoperative diagnostic incompatibility was seen in 6 cases (12%). 8. The artificial valves used in the replacement surgery were lonescu-Shiley bovine xenograft in 6 cases and Carpentier-Edwards porcine xenograft in 10 cases.

  • PDF

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF