Development of a Oil-Cooler for High-Speed CNC Lathe (고속 CNC선반용 공랭식 오일 냉각기 개발)

  • Yum, Man-Oh
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.4
    • /
    • pp.11-16
    • /
    • 2003
  • Recently, CNC lathe is in need of higher speed for precision works. So more intensive and compact heat exchanger is necessary to cool down the heat in short time from drills and works during high speed working. In this study, to increase heat transfer coefficient per unit volume, inner groove tube is designed and compact oil cooler, 57% volume of conventional type, is manufactured. The heat transfer performance is experimented and is compared with the performance of conventional type.

  • PDF

A Noise Control of Cooler Housing in Large Scale Vertical Motor (대형 수직전동기 Cooler Housing의 이상소음 제어)

  • Joo, W.H.;Kim, D.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.132-137
    • /
    • 2000
  • Recently, a severe noise problem was encountered during a shop test of large scale vertical motor. In order to identify the noise characteristics and propose the countermeasure, a variety of experiments such as sound excitation test and contribution analysis was earned out in addition to ordinary noise and vibration measurements. The results showed that the severe noise level was dominated by an acoustic resonance phenonmenon in the cooler housing and higher sound power of outer fan. Through proper treatments, the noise level could be acceptable.

  • PDF

SPICE-Compatible Modeling of a Microbolometer Package Including Thermoelectric Cooler (열전 냉각기를 포함하는 볼로미터 패키지의 SPICE 등가 모델링)

  • Han, Chang Suk;Park, Seung Man;Kim, Nam-Hwan;Han, Seungoh
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.44-48
    • /
    • 2013
  • For a successful commercialization of microbolometer, it is required to develop a robust package including thermal stabilizing mechanism. In order to regulate the temperature within some operating range, thermoelectric cooler is generally used but it's not easy to model the whole package due to the coupled physics nature of thermoelectric cooler. In this paper, SPICE-compatible modeling methodology of a microbolometer package is presented, whose steady-state results matched well with FEM results at the maximum difference of 5.95%. Although the time constant difference was considerable as 15.7%, it can be offset by the quite short simulation time compared to FEM simulation. The developed model was also proven to be useful for designing the thermal stabilizer through parametric and transient analyses under the various working conditions.

PI Controller Design Based on Characteristic Parameters and Zero Position Adjustment for an Oil Cooler System (오일쿨러시스템의 특성근과 영점 조절에 의한 고성능 PI 제어기 설계)

  • Choi, Do-Kyung;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.83-90
    • /
    • 2016
  • This study proposes a high-performance PI controller design method for an oil cooler system in conjunction with zero position adjustment and the characteristic parameters in its closed loop control system. The characteristic parameters included PI gains are decided by design specifications such as settling time and overshoot. The fine tuning on decided gains was performed by adjustment the zero position to get more desirable control performances. The simulations and experimental results show that the proposed PI controller design for an oil cooler system was possible to accomplish good control performances and to satisfy the design specifications.

A development of linear compressor for a cryogenic stirling cooler (극저온 스터링 냉동기용 선형 압축기 개발)

  • 지상우;임경화;강희석;강경태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.731-734
    • /
    • 2001
  • A cryogenic stirling cooler is currently under development at Korea Institute of Industrial Technology(KITECH). Cryocooler has many kinds of types. The stirling cooler is the most appropriate one for under 80K with the trait of long life cycle and small size. The stirling cooler uses helium as a working fluid. Helium is pressurized by the linear compressor which is driver by linear motor. In this paper, the change of pressure and volume is studied by the isothermal analysis method. It is necessary to investigate the optimized pressure to meets the highest COP. The compressor's piston and expender's displacer interact according to the working fluid's pressure level and the phase difference. This paper presents the relation between the initial pressure and the work of cryocooler. By that results, we can predict the performance of linear compressor.

  • PDF

Effects of Individual Components on the System Performance in a Desiccant Cooling System (제습냉방시스템에서 요소성능이 시스템성능에 미치는 영향)

  • Chang, Young-Soo;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.687-694
    • /
    • 2007
  • Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.

Design and Fabrication of Laser Diode Integrated with Peltier Cooler (열전 냉각기가 집적된 레이저 다이오드)

  • 이상일;박정호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.159-165
    • /
    • 1995
  • A double-heterostructure mesa-stripe-geometry laser diode integrated with thermoelectric Peltier cooler has been designed and fabricated. Epi-layers have been grown by metal organic chemical vapor deposition(MOCVD) method. Peltier cooling effect has been measured for devices with a mesa width of 14$\mu$m and a cavity length of 380$\mu$m. The effects of thermoelectric cooling could be shown by measuring the optical output of the laser with the increase of the current in the thermoelectric cooler. While the input courrent of the laser was maintained at 250mA, the optical output was decreased from 4.8mW to 3.8mW due to heating, but with the thermoelectric cooler on the optical output power was recovered by more than 40%. The results show that the complicated cooling device is not needed since the cooling can be achevied by the developement of the fabrication processing.

  • PDF

Heat Transfer and Pressure Drop of $CO_2$ Gas Cooler in a Helically Coiled Tube (헬리컬코일형 $CO_2$ 가스쿨러의 열전달과 압력강하)

  • Kyoung, Nam-Soo;Yu, Tae-Guen;Son, Chan-Hyo;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.246-247
    • /
    • 2005
  • The paper presents the heat transfer characteristics during cooling process of carbon dioxide($CO_2$) in a helically coiled tube. The main components of the apparatus consist of a receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section with the inner diameter 4.55 [mm] is a tube in tube type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The main results were summarized as follows : The heat transfer coefficient increases with respect to the decrease of the gas cooler pressure in a supercritical region and the increase of the refrigerant mass flux. The pressure drop decreases in increases of the gas cooler pressure and increases with respect to increases the refrigerant mass flux.

  • PDF