• Title/Summary/Keyword: Coolant flow analysis

Search Result 257, Processing Time 0.025 seconds

The Characteristics of Hydraulic Valve for a Passive Reactor (피동형 원자로의 Hydraulic Valve 특성 실험)

  • Kim, Sang-Nyung;Kim, Yoong-Seock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1083-1090
    • /
    • 1998
  • A kind of three-way check valve, so called hydraulic calve was proposed for the substitute of the density lock of passive reactor such as SPWR (System-Integrated Pressurized Water Reactor). The function of the valve are the separation of the borated water from main coolant loop for normal operation and the insurge of the water into the loop for shutdown and the removal of the decay power when the main coolant flow rate is not enough. To verify the operability and the characteristics of the valve, experimental works were executed with 1/3 scale model calve. Also a diffuser model was proposed for the theoretical analysis of the valve.

A numerical study on the optimum size for the orifice located on the steam generator cassette of integral reactor (일체형원자로 증기발생기 카세트 하단에 설치된 오리피스의 최적설계 연구)

  • Kang Hyung Seok;Yoon Juhyeon;Kim Hwan Yeol;Cho Bong Hyun;Lee Doo Jeong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.75-81
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt capacity named SMART(System-integrated Modular Advanced ReacTor) is currently under development at KAERI(Korea Atomic Energy Research Institute). One of the major design features of the integral reactor is locating the steam generators(SG) inside reactor vessel and eliminating the possibility of LB LOCA(large Break Loss of Coolant Accident). Orifices are fitted at the low part of steam generator cassette to stabilize and balance coolant flow distribution in the MCP (Main Circulation Pump) pressure header. A sensitivity analysis is conducted to determine the optimum orifice size using computer code 'CFX'.

  • PDF

An ultra-long-life small safe fast reactor core concept having heterogeneous driver-blanket fuel assemblies

  • Choi, Kyu Jung;Jo, Yeonguk;Hong, Ser Gi
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3517-3527
    • /
    • 2021
  • New 80-MW (electric) ultra-long-life sodium cooled fast reactor core having inherent safety characteristics is designed with heterogeneous fuel assemblies comprised of driver and blanket fuel rods. Several options using upper sodium plenum and SSFZ (Special Sodium Flowing Zone) for reducing sodium void reactivity are neutronically analyzed in this core concept in order to improve the inherent safety of the core. The SSFZ allowing the coolant flow from the peripheral fuel assemblies increases the neutron leakage under coolant expansion or voiding. The Monte Carlo calculations were used to design the cores and analyze their physics characteristics with heterogeneous models. The results of the design and analyses show that the final core design option has a small burnup reactivity swing of 618 pcm over ~54 EFPYs cycle length and a very small sodium void worth of ~35pcm at EOC (End of Cycle), which leads to the satisfaction of all the conditions for inherent safety with large margin based on the quasi-static reactivity balance analysis under ATWS (Anticipated Transient Without Scram).

A Study on Thermal and Modal Characteristics for EGR System with Dimpled Rectangular Tube (딤플 사각 튜브형 배기 가스 재순환 시스템의 열 및 진동 특성에 관한 연구)

  • Seo, Young-Ho;Heo, Sung-Chan;Kwon, Young-Seok;Ku, Tae-Wan;Kim, Jeong;Kang, Beom-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.115-125
    • /
    • 2008
  • Recently, Exhaust Gas Recirculation (EGR) system which re-flow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine has been used to solve the serious air pollution. For the design and mass production of EGR system, it is essential to ensure structural integrity evaluation. The EGR system consisted of ten dimpled oval core rectangular tubes, two fix-plates, two coolant pipes, shell body and two flanges in this study. To confirm the safety of the designed system, finite element modeling about each component such as the dimpled oval core tube with the dimpled shape and others was carried out. The reliability of EGR system against exhaust gas flow with high temperature was investigated by flow and pressure analysis in the system. Also, thermal and strength analysis were verified the safety of EGR system against temperature change in the shell and tubes. Furthermore, modal analysis using ANSYS was also performed. From the results of FE analysis, there were confirmed that EGR system was safe against the flow of exhaust gas, temperature change in EGR system and vibration on operation condition, respectively.

Prediction of Vortex Reducing Effect by a Peforated Baffle in the Inlet Plenum of a Research Reactor (연구용 원자로 유입 공동에서 다공형 차폐물에 의한 와류 감쇄효과 예측)

  • Park J. H.;Chae H. T.;Park C.;Kim H. I.
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.11-17
    • /
    • 2004
  • CFD analysis was performed to figure out flow behavior in the inlet plenum of new research reactor where coolant is injected to the flow tubes with the fuel assembly. The computation results showed that large-scale vortices are generated in the inlet plenum by flow stream injected from inlet pipe. These vortices are divided into small vortices and reversed their revolution. They may lead to flow-induced vibration of fuel assembly, moreover, which has been regarded as a cause of fretting wear of fuel assembly. Also there is an another important thing that average velocity of each flow-tube is uneven showing difference in maximum 18%. So it has been suggested that perforated baffle will be installed to prevent the formation of vortex in the inlet plenum. Two perforated baffles, one is flow skirt and the other is muffler type flow straightener, were proposed and their effect was evaluated using commercial CFD code, Fluent. According to CFD analysis for two perforated baffles, it was confirmed that both of them can prevent or reduce vortex formation in the inlet plenum and make average velocity of each flow tube more even.

Flow Characteristics of a Primary Cooling System in 5 MW Research Reactor (5MW 연구용 원자로의 1차 냉각 계통 유동 특성)

  • Park, Young-Chul;Lee, Young-Sub
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.5-10
    • /
    • 2010
  • 5MW, open pool type research reactor, is commonly used to education and experimental purpose. It is necessary to prepare a standardization of system designs for considering a demand. HANARO has prepared the standardization of 5MW research reactor system designs based on the design, installation, commissioning and operating experiences of HANARO. For maintaining an open pool type reactor safety, a primary cooling system (after below, PCS) should remove the heat generated by the reactor under a reactor normal operation condition and a reactor shutdown condition. For removing the heat generated by the reactor, the PCS should maintain a required coolant flow rate. For a verification of the required flow rate, a flow network analysis of the PCS was carried under a normal operating condition. Based on the flow network analysis result, this paper describes the PCS flow characteristics of a 5MW open pool type research reactor. Through the result, it was confirmed that the PCS met design requirements including design flow rate without cavitation.

Analytical Assessment on the Cooling Structure of In-wheel Driving Inverter (인휠 모터 구동용 인버터의 냉각구조에 대한 해석적 평가)

  • Kim, Sung Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In-wheel driving inverter inside engine room sometimes operates in the harsh environment like high temperature of about $105^{\circ}C$. Especially, the size and power density of the inverter has become smaller and more increased. Thus, it is essential to manage the temperature of the inverter with IGBT (Insulated Gate Bipolar Transistor) switching devices for performance and endurance, because the temperature can be getting increase. In this paper, we performed the thermal flow analysis of inverter models with wave type and pin fin type cooling channels, and investigated the heat transfer characteristics of the inverter models using cooling water on channels at 8 L/min and $65^{\circ}C$. Also, we compared the thermal performance under various conditions such as coolant flow rate and layered power module structure. Therefore, we determined the feasibility of the initial inverter models and the thermal performance enhancement.

Numerical Analysis of Fluid Flow in a Regenerative Cooling Passage (재생냉각 유로 내의 유동에 관한 수치해석)

  • 조원국
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2000
  • A computational analysis has been made on fluid flow in a regenerative cooling Passage for a reduced size liquid rocket engine to predict pressure drop and heat transfer rate in it. The contraction/expansion of the cross sectional area of the passage turn out to increases both the pressure loss and the heat transfer rate of the duct. The changes of the cross sectional area near the nozzle throat are effective to protect the throat which suffers from severe thermal load. Also given is the qualitative characteristics of the performance of the regenerative cooling system due to the variation of coolant flow rate.

  • PDF

The Study about the Performance-Analysis of a Automotive Engine Cooling System (엔진 냉각시스템 성능해석에 관한 연구)

  • Shin, Chang-Hoon;Lee, Seung-Hee;Park, Warn-Gyu;Jang, Gi-Lyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.39-48
    • /
    • 2006
  • An engine cooling system affects overall performances of an engine which has been recently requested higher power in more confined engine room. The design of efficient cooling system demands a great effort to effectively correlate with each components, such as water jacket, radiator, coolant pump, cooling fan, etc. Thus, the aim of this study is to provide the design tool of the cooling system in the early design stage by enabling for the designer to accurately predict the engine cooling performances. This user-friendly design tool has various ways to assemble each components and control the running condition with related database. The present design tool was simulated and compared with experimental data. As a result, the inlet and outlet temperature of the radiator agree very well with experiments. It was concluded that the present design tool could be effectively used for the design of the engine cooling system.

Improvement in the DNBR Modeling of RETRAN for Safety Analyses of Westinghouse Nuclear Power Plants

  • Cheong, Ae-Ju;Kim, Yo-Han
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.596-609
    • /
    • 2002
  • Korea Electric Power Research Institute has developed the in-house safety analysis methodologies for non-LOCA(Loss Of Coolant Accident) events based on codes and methodologies of vendors and Electric Power Research Institute . According to the new methodologies, analyses of system responses and calculation of DNBR(Departure from Nucleate Boiling Ratio) during the transient have been carried out with RETRAN code and a sub-channel analysis code, respectively. However, it takes too much time to calculate DNBR for each case using the two codes to search for the limiting case from sensitivity study. To simplify the search for the limiting case, accordingly, RETRAN code has been modified to roughly calculate DNBR using hot channel modeling. The W-3 correlation is already included in RETRAN as one of the auxiliary DNBR models. However, WRB-1 and WRB-2 correlations required to analyze some Westinghouse type fuels are not considered in RETRAN DNBR models. In this paper, the RETRAN DNBR models using the correlations have been developed and the partial and complete loss of forced reactor coolant flow events have been analyzed for Yonggwang units 1 and 2 with the new methodologies to validate the models. The results of the analyses have been compared with those mentioned in the chapter 15 of the Final Safety Analysis Report.