CFD를 이용한 피트의 지중열 모델 구축에 관한 연구 (A Geothermal Model of Pit Area Using Computational Fluid Dynamics)

  • 민준기;김정태
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.11-16
    • /
    • 2008
  • This research has established CFD model on pit's cool-tube system through heat and air movement simulations, of which data was based on experimental and verification. This research work verified the effectiveness of the cool-tube system by analysing temperature, humidity and air current of the actually installed case. Also, we analysed heat transfer through air current simulation and the results are as followings. Firstly, we experiment on temperature, humidity and speed of air currents of the cool tube system with pit space during the month of May (spring). The average exterior temperature was $16.1^{\circ}C$, and $18.2^{\circ}C$ for the pit, $24.7^{\circ}C$ for the compressor room. Secondly, based on measured data of real case, we have analysed heat transfer through air current simulation and verified our proposed model. The actual measurement of average temperature of exhaust air of the pit's area is $19.7^{\circ}C$ with tolerance of $-0.33^{\circ}C{\sim}-0.6^{\circ}C$ compared to above simulations. Thirdly, having verified air current simulation model with formation of 260,000 and 1,000,000 cells, we could get reasonable near values with 260,000 cells. Lastly, the next step of research would be focused on proposing the best possible pit's cool-tube system after analysis of heat transfer of the air current simulation based on verified CFD model.

CFD를 이용한 기상청 지중온도의 피트부분 지중열원 유용성 평가에 관한 연구 (Effectiveness Assessment on the Soil Temperature of KMA as Ground Heat Source Using CFD in Pit Area)

  • 민준기;김정태
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.49-54
    • /
    • 2008
  • The experimental of temperature, humidity and velocity was taken from the underground pit which utilized the system of ground heat source quite similar to the cool-pit system. Also, through CFD analysis, one could review the effectiveness of analysis of future alternatives. Furthermore, the temperature range of mock up cool-pit system was analyzed by inputting the weather data of annual average soil temperature provided by KMA(Korea Meteorological Administration) into the fluid simulation of anticipated heat distribution. Firstly, the difference between the temperature of air exhaust of the pit or the temperature of air supply of the compressor room and the experimental data for the month of May from the CFD analysis came out to be $0.6^{\circ}C$ and $0.9^{\circ}C$ respectively with tolerance of 3.1% and 4.7%. Secondly, the difference between the temperature of air exhaust of the Pit or the temperature of air supply of the compressor room and the experimental data for the month of July from the CFD analysis came out to be $0.8^{\circ}C$ and $1.1^{\circ}C$ respectively with tolerance of 3.3% and 4.5%. Thirdly, for the month of May, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.9^{\circ}C$ and $1.8^{\circ}C$ respectively with tolerance of 10.7% and 9.8%. Fourthly, for the month of July, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.1^{\circ}C$ and $1.4^{\circ}C$ respectively with tolerance of 4.5% and 5.8%. The result of above experiments allowed us to establish CFD model set up as a verification tool that is based on experimental data collected within the Pit area. Also, one could confirm the possibility to apply weather data of soil temperature provided by KMA in order to anticipate proper value for CFD analysis.

益山郡 彌勒寺址의 堆積層에 對한 花紛分析的 硏究 (Palynological study of the alluvial vally plain deposits from the miruksa site, iksan-gun, korean)

  • Choi, Kee-Ryong
    • The Korean Journal of Ecology
    • /
    • 제15권1호
    • /
    • pp.59-65
    • /
    • 1992
  • Pollen analysis to clear vegetational history of korea was carried out on the deposite taken from the pit of the miruksa site, south-western korea(36o00'18'N, 127o1'12'E, 10m in alt.). This area has been known as the cool temperate zone(southern zone) according to yim and kira(1975). But, now we can not found the original vegetation because the area has been disturbed severely and almost area changed to cultivated land.the area is one of the most developd area in early agricultural stage of korea. By the pollen diagram, three local pollen zones are distinguished in this site, bottom to surface, as following. is-Ⅰ :pinus-quercus zone (140∼120 cm, sample 1 and 2) is-Ⅱ :ulmus+zelkova zone(120∼84 cm, sample 3∼6) is-Ⅲ :pinus zone(84∼0 cm, sample 7 ∼13) is-Ⅰ is characterized by high values in frequences of pinus, the temperate conifer and quercus the cool temperate oak, and is-Ⅱ zone by the decrease of quercus and increase of ulmus and increase of ulman+zelkova as ravine forest elements, isⅢ zone is characterized by pinus, especially, based on data of sample no.9.

  • PDF