• 제목/요약/키워드: Cooing Condition

검색결과 9건 처리시간 0.024초

가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구 (Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment)

  • 배치혜;배누리;전정윤
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

예압과 냉각조건에 따른 고주파 모터 내장형 주축계의 열특성 (Thermal Characteristics of the High Frequency Motor Spindle according to the Bearing Preloads and Cooling Conditions)

  • 최대봉;김수태;정성훈;김진한;김용기
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.31-36
    • /
    • 2005
  • Use of the high frequency motor spindles are increasing for the high speed machine tools recently. The important problem in the high speed spindles is to reduce and minimize the thermal effect by the motor and ball hearings. Thermal characteristics according to the bearing preload and spindle cooling are studied for the spindle with the oil mist lubrication and high frequency motor. Temperature distribution and thermal displacement according to the spindle speed, preload and flow rate are measured. Temperature distribution and thermal displacement of the high speed spindle system can be estimated reasonably by using the three dimensional model through the finite element method. The results of analysis are compared with the measured data. This study supports thermal optimization and find out more effective cooling condition. This paper show that the suitable preload and spindle cooling are very effective to minimize the thermal effect by the motor and ball bearings.

예압과 냉각조건에 따른 고주파 모터 내장형 주축계의 열특성 (Thermal Characteristics of the High Frequency Motor Spindle according to the Bearing Preloads and Cooling Conditions)

  • 최대봉;김수태;정성훈;김진한;김용기
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.138-143
    • /
    • 2005
  • The important problem in the high speed spindles is to reduce and minimize the thermal effect by the motor and ball bearings. Thermal characteristics according to the bearing preload and hollow shaft cooling are studied for the spindle with the oil mist lubrication and high frequency motor. Temperature distribution and thermal deformation according to the spindle speed, preload and flow rate are measured by thermocouple and gap sensor. Temperature distribution and thermal deformation are analyzed by using the finite element method. The results of analysis are compared with the measured data. This paper show that the suitable preload and hollow shaft cooling are very effective to minimize the thermal effect by the motor and ball bearings. This study indicates that temperature distribution and thermal deformation of the high speed spindle system can be estimated reasonably by using the three dimensional model through the finite element method and supports thermal optimization and more effective cooling method.

  • PDF

에어컨 온도상승에 따른 온열쾌적성 변화에 관한 연구 (Research on Thermal Comfort by Increasing Air Conditioner Temperature)

  • 김형철;금종수;김동규;정용현
    • 수산해양교육연구
    • /
    • 제18권2호
    • /
    • pp.77-84
    • /
    • 2006
  • This research evaluates thermal comfort by comparing the case of maintain cooing temperature of room with the case of raising it at the point of time that human body begins to adapt. An experiment uses constant temperature & humidity chamber 2 places. Pretesting room make up summer season environment, the testing room control by air-conditioner. In condition that maintain temperature of $33^{\circ}C$. The subjects stay in the pretesting room during the 30 minute for the heat storage amount of the normal summertime. The subjects stay in the testing room under each case (case 1: maintaining $24^{\circ}C$, case 2: maintaining $26^{\circ}C$, case 3: up $1^{\circ}C$ after maintaining $24^{\circ}C$ during 30 minute, case 4: up $1^{\circ}C$ after maintaining $26^{\circ}C$ during 40 minute). 1. Result of comparison of case 1 and case 2 appears that thermal sensitive vote examine from slight cool to cool and thermal comfort examine slight comfort by temperature rise at human body adaptation point of time.2. Test of case 3 and case 4 appear similar value at thermal sensitive vote and thermal comfort.3. Through the case 2 and case 4, continuous thermal comfort maintain at $24^{\circ}C$, if raise $26^{\circ}C$, same thermal comfort maintain after a human body adaptation temperature rising effect bring energy saving.

Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator

  • Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Hong, Yong-Ju;Koh, Deuk-Yong;Yeom, Hankil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.50-53
    • /
    • 2012
  • This paper describes experimental study on GM-type pulse tube refrigerator (PTR). In a PTR, the pulse tube is only filled with working gas and there exists secondary flow due to a large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus, the cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube refrigerator is fabricated and tested. The cooing performance of the fabricated PTR is measured as varying cold-head orientation angle and the results are used as reference data. Then, we divided interior space of pulse tube into three segments, and fixed the various size of screen mesh at interface of each segment to suppress the performance degradation due to secondary flow. For various configuration of pulse tube, no-load test and heat load test are carried out with the fixed experimental condition of charging pressure, operating frequency and orifice valve turns. From experimental results, the fine screen mesh shows the effective suppression of performance degradation for the large orientation angle, but the use of screen mesh cause the loss of cooling capacity rather than the case of no insertion into pulse tube. It should be compromised whether the use of screen mesh in consideration of the installation limitation of a GM-type pulse tube refrigerator.

API X80 라인파이프강의 미세조직과 기계적 특성에 미치는 냉각조건의 영향 (Effect of Cooling Conditions on Microstructures and Mechanical Properties in API X80 Linepipe Steels)

  • 한승엽;신상용;이성학;배진호;김기수
    • 대한금속재료학회지
    • /
    • 제47권9호
    • /
    • pp.523-532
    • /
    • 2009
  • In this study, four API X80 linepipe steel specimens were fabricated with varying cooling rates and finish cooling temperatures, and their microstructures and crystallographic orientations were analyzed to investigate the effects of cooling conditions on their tensile and Charpy impact properties. All the specimens consisted of acicular ferrite, granular bainite, and secondary phases such as martensite and martensiteaustenite constituent. The volume fraction of secondary phases increased with increasing cooling rate, and the higher finish cooling temperature resulted in the reduction in volume fraction and grain size of secondary phases. According to the crystallographic orientation analysis data, the effective grain size and unit crack path decreased as fine acicular ferrites having a large amount of high-angle grain boundaries were homogeneously formed, thereby leading to the improvement of Charpy impact properties. The specimen fabricated with the higher cooling rate and lower finish cooling temperature had the highest upper shelf energy and the lowest energy transition temperature because it contained a large amount of fine secondary phases homogeneously distributed inside fine acicular ferrites, while its tensile properties well maintained.

극저온 냉동기를 활용한 기체 수소 예냉 시스템 검증에 관한 연구 Part II: CFD 시뮬레이션 (Study on Validity of Pre-cooling System for Hydrogen Gas Using Cryocooler Part II: CFD Simulation)

  • 서영민;노현우;하동우;구태형;고락길
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.439-446
    • /
    • 2023
  • In this study, the computational fluid dynamics (CFD) simulations were conducted to verify the cooling capacity of the cryocooler used for pre-cooling of hydrogen gas. Based on the experimental results, the effect of the flow rate on a copper pipe attached to the bottom of the cryocooler was investigated. In this study, the temperature data was calculated through the change of boundary condition for heat flux in the copper pipe. In addition, the cooling capacity of the cryocooler for pre-cooling hydrogen gas was considered by calculating the cooling temperature according to the flow rate in the certified operating range. Consequently the pre-cooing system for hydrogen gas was validated with a reasonable accuracy through CFD simulations.

우리나라 제사공장의 공정 관리실태에 관한 조사연구 (Studies on the Processing and Management Forms of Filatures)

  • 송기언;이인전
    • 한국잠사곤충학회지
    • /
    • 12호
    • /
    • pp.37-45
    • /
    • 1970
  • 1969년도 우리나라 제사공장의 공정관리 실태를 조사분석한 결과는 다음과 같다. 1 춘추잠기 공히 최성일을 포함한 5일간(최성일전후 각 2일)의 출하량이 전공판량의 약 80% 내외이고 최성일의 -3일까지 및 +3일이후의 출하량은 가각 10% 내외이다. 2. 생견의 운반도로상태는 92% 내외가 비포장도로이고 전공장이 구견량의 40% 내외를 40km이상되는 공판장에서 트럭으로 운반하고 있는 실정이므로 생견수송중의 격동에 의한 견질손상을 최소한으로 감소시킬 수 있는 생견의 새로운 포장방법이 청구되어야 할 것이다. 3. 전공장의 22%가 생사품위의 저하요인이 되고 있는 저온건조고만을 설치하고 있는 실정이드로 이들 공장에 대한 열풍건견기의 설치는 시급하다고 본다. 4. 원료견의 가일조제방법은 50% 내외가 정상(1.2.3.4등견), 정하(5.6등견)로 구분하고 있는바 우리나라의 견질성상으로 볼 때 정상(1.2등견), 정중(3.4 등견) 정하(5.6등견)로 구분하여 조제하는 방향으로 개선시켜야 될 것이다. 5. 선제견비율은 다조조사용이 10% 내외 자동조사용이 15% 내외로서 다조용보다 자동용이 높았으며 대 1인당 1일 선견능력은 약 80~100kg이었다. 6. 자견조건은 원료견의 해서가 불량할수록 자견시간 자견압력 및 자견온도가 높았으며 자동조사용 및 옥사조사용의 원료견은 다조조사용의 원료견보다 약자상태이었다. 7. 자동조사가 다조조사보다 1~2$^{\circ}C$의 저온에서 약 2배의 권취속도로 조사하고 있다. 8. 재조온습도는 실내가 $25^{\circ}C$, 67.2%RH 기내가 32.3$^{\circ}C$ 51.9% RH이었고 권취속도는 233m/min 대 1인당 담당창수는 7.5창이었으며 타래의 형태는 전공장이 배인이었다. 9. 제사용수의 용수원은 약 75%가 지하수이고 정수시설이 미비되어 있는 공장이 약 48%인바 이들 공장에 대한 정수시설의 완비는 시급한 과제이다. 10. 대부분의 공장이 자체검사시설로서 검위형, 무척기 Seriplane 검사시설을 보유하고 있다. 11. 진공삼투기는 전공장의 90%이상이 재조공정에서 약 20% 공장이 자견공정에서 활용하고 있다. 12. 제사공정에서 화학약제를 사용하는 공장은 약 21%에 불과하며 사용하는 약제는 대부분의 공장이 자견과정에서는 Seracol "100"을 재조과정에서는 Seracol "500"이었다. 13. 이상의 조사결과를 종합하여 볼 때 공정관리면에서는 각제사공장간에 큰 차이를 나타내고 있으므로 강습회 등을 통한 각공장간의 기술교류는 우리나라 제사업의 생산성을 제고시키는 한 요인이 될것이다.성을 제고시키는 한 요인이 될것이다.

  • PDF