• Title/Summary/Keyword: Converter-based generator

Search Result 148, Processing Time 0.026 seconds

A Review of Electric Ship Propulsion System (선박용 전기추진 장치의 기술동향)

  • 박정태
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.22-25
    • /
    • 2000
  • This paper introduces the ship propulsion system in different aspects. In fact there are many types to accomplish electric propulsion. The latest installations are based on fixed generator speed and motor speed control. The AC motor drive systems with synchroconverter cycloconverter PWM converter are chosen for the ship electric propulsion. The configurations of the ship electric propulsion. The configurationso of the ship electric propulsion system must be considered about following criteria : torque and speed performances redundancy cost harmonics available space and shape. This paper introduces possible configurations of the ship electric propulsion and the major and minor points.

  • PDF

A study on the booster for a small-capacity fuel cell power generator (소출력 연료전지 발전용 booster연구)

  • Han, Soo-Bin;Jung, Bong-Man;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.504-507
    • /
    • 1991
  • Modelling and simulation of booster which is used as step-up DC/DC converter for small scale fuel cell generator is studied. And 2kW booster based on this result is designed. Especially, booster efficiency related with fuel cell and control characteristics are analyzed and a 2kW booster is experimented in various operating condition. As a result, power conversion efficiency is above 74% throughout the whole operating range.

  • PDF

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

An Optimal Maximum Power Point Tracking Algorithm for Wind Energy System in Microgrid

  • Nguyen, Thanh-Van;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.382-383
    • /
    • 2018
  • To increase the efficiency of a wind energy conversion system (WECS), the maximum power point tracking (MPPT) algorithm is usually employed. This paper proposes an optimal MPPT algorithm which tracks a sudden wind speed change condition fast. The proposed method can be implemented without the prior information on the wind turbine parameters, generator parameters, air density or wind speed. By investigating the directions of changes of the mechanical output power in wind turbine and rotor speed of the generator, the proposed MPPT algorithm is able to determine an optimal speed to achieve the maximum power point. Then, this optimal speed is set to the reference of the speed control loop. As a result, the proposed MPPT algorithm forces the system to operate at the maximum power point by using a three-phase converter. The simulation results based on the PSIM are given to prove the effectiveness of the proposed method.

  • PDF

Combined Dithered Sigma-Delta Modulation based Random PWM Switching Scheme

  • Kim, Seo-Hyeong;Choi, Woo-Jin;Choi, Se-Wan;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.667-678
    • /
    • 2009
  • The PWM (Pulse Width Modulation) control signals have a drawback in that their power spectrum tends to be concentrated around the switching frequency and the resulting harmonic spikes cause an EMI (Electromagnetic Interference) and switching losses in semiconductors, etc. The SDM (Sigma-Delta Modulation) is a type of switching modulation used to reduce these harmonic spikes, and several SDM schemes are investigated in this paper. In the DSDM (Dithered SDM), the SDSDM (Space-Dithered SDM) and TDSDM (Time-Dithered SDM), the signals are classified by the location of their random dither additions. In these schemes, the switching frequency is spread by a random dither generator placed on the input or the output parts. Experimental results are presented where the advantages of the new proposed CDSDM (Combined Dithered SDM) are confirmed by applying to a buck converter.

Hardware Simulator Development for a 3-Parallel Grid-Connected PMSG Wind Power System

  • Park, Ki-Woo;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.555-562
    • /
    • 2010
  • This paper presents the development of a hardware simulator for a 3-parallel grid-connected PMSG wind power system. With the development of permanent magnetic materials in recent years, the capacity of a PMSG based wind turbine system, which requires a full-scale power converter, has been raised up to a few MW. Since it is limited by the available semiconductor technology, such large amounts of power cannot be delivered with only one power converter. Hence, a parallel connecting technique for converters is required to reduce the ratings of the converters. In this paper, a hardware simulator with 3-parallel converters is described and its control issues are presented as well. Some experimental results are given to illustrate the performance of the simulator system.

The Harmonic Current Mitigation of DFIG under Unbalanced Grid Voltage and Non-linear Load Conditions

  • Thinh, Quach Ngoc;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.83-84
    • /
    • 2011
  • This paper presents an analysis and a novel strategy for a doubly fed induction generator (DFIG) based wind energy conversion system under unbalanced grid voltage and non-linear load conditions. A proportional-resonant (PR) current controller is applied in both grid side converter (GSC) and rotor side converter (RSC). The RSC is controlled to mitigate the stator active power and the rotor current oscillations at double supply frequency under unbalanced grid voltage while the GSC is controlled to mitigate ripples in the dc-link voltage and compensate harmonic components of the network current. Simulation results using Psim simulation program are presented for a 2 MW DFIG to confirm the effectiveness of the proposed control strategy.

  • PDF

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF

Design of Suitable a New Active Clamp Sepic-Flyback Converter for a Fuel Cell Generation System (연료전지 발전시스템에 적합한 새로운 능동 클램프 Sepic-Flyback 컨버터의 개발)

  • Lee, T.W.;Jang, S.J.;Kim, S.S.;Lee, B.K.;Kim, H.S.;Won, C.Y.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.258-265
    • /
    • 2006
  • In this paper, an active clamping sepic-flyback converter has been proposed, which is suitable for a fuel cell based power generation system. The proposed converter is superposition of sepic converter mode and flyback mode. It has outstanding high boosting output voltage, component utilization and high efficiency characteristics under the inherently severe low output voltage of the fuel cell generator. In this paper, the validity of the proposed converter has been verified by the informative simulation and experimental results that make used of the PEMFC.

A Development of Eddy Current Testing System for Steam Generators Inspection in Nuclear Power Plants (원전 증기발생기 와전류검사 시스템 개발)

  • Moon, Gyoon-Young;Cho, Chan-Hee;Yoo, Hyun-Joo;Lee, Tae-Hun;Cho, Yong-Bae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.40-47
    • /
    • 2013
  • The capacity factor of nuclear power plant in Korea is the highest level in the world. However, the integrity assessment of nuclear power plant is depended on foreign country. Especially, most eddy current testing systems for inspecting steam generators in nuclear power plant are currently imported from USA, Canada, and so on. Therefore, the eddy current testing system can react more active and adaptive from economic and managerial standpoint for actual nuclear power plants in Korea is required. In this paper, an eddy current testing system for inspecting steam generators in nuclear power plants is introduced. Frequency generator, analog circuit, analog digital converter circuit, and digital control circuit are composed in eddy current testing system. A benchmarking of acquisition system and acquisition software, eddynet 11i made by Zetec, and modifications are carried out based on the test environment of Korea nuclear power plants. Finally, all eddy current apparatus are integrated to inspect steam generator tubes in nuclear power plants.