• 제목/요약/키워드: Converter control

검색결과 3,153건 처리시간 0.031초

다양한 부하조건에 호환 가능한 프로그래머블 스마트 충전기 (Programmable Smart Charger Compatible to Various Load Conditions)

  • 조강타;금문환;한상규;오동성;사공석진
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.357-363
    • /
    • 2014
  • A programmable smart charger compatible to various load conditions is proposed in this paper. Since the proposed smart charger is compatible to various mobile devices having different rated voltage and power, it is convenient for carrying and easy to standardize many kinds of battery chargers. Moreover, since it uses the input impedance and built-in PMIC (Power management IC) of the load system to recognize the connection state and specifications of load system, hardware changes of load system is not only hardly necessary but it also features no addition communication cable and easy implementation. To confirm the validity of the proposed charger, the theoretical analysis and experiment results from a prototype compatible to three load conditions 5V/1A, 5V/2A and 12V/1A are provided.

고속열차용 주전력변환장치 궤도회로 간섭 고조파 저감 제어 (The Harmonics Interference Control of Track Circuit and Traction Converter for High Speed Train)

  • 조성준;정만규;이광주;이헌수;유지윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.227-228
    • /
    • 2014
  • 열차가 주행하는 선로에 설치되는 궤도회로는 레일 자체를 전기회로의 일부로 사용하여 일정 구간 내의 차량 유무를 판단하기 위한 회로이다. 국내의 경우 사용 주파수에 따라 전원전압 주파수의 짝수 고조파 대역을 사용하는 고속선 궤도회로와 홀수 고조파 대역을 이용하는 일반선 궤도회로로 구분할 수 있다. 이러한 궤도회로가 설치된 선로를 주행하는 고속차량의 주전력변환장치 컨버터는 단위 역률 제어를 수행하기 위하여 전원전압의 홀수 배수의 스위칭 주파수를 가지고 있기 때문에 컨버터 동작 시 가선전류에 고조파 전류가 생성된다. 이 때 컨버터부에서 발생되는 고조파 전류의 주파수와 궤도회로의 사용 주파수 대역이 일치하는 경우에 궤도회로의 오작동을 유발할 수 있다. 본 논문에서는 입력 컨버터부에서 사용하는 스위칭 주파수를 운행 구간에 따라 가변시켜 궤도회로 간섭 고조파 성분을 제어하는 방법을 제안하고 시험을 통해 성능을 확인하였다.

  • PDF

Multi Channel LED 조명 Module 구동에서 최대 효율을 위한 최대 Channel 전압 감지회로 (Feedback Circuit of Maximum LED Channel String Voltage Detection Converter for Energy Saving on Multichannel LED Module)

  • 김현식;김기원;김기훈;김유신;송상빈
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.938-941
    • /
    • 2012
  • LED is divided to multichannel in order not to exceed a certain voltage in aspects of electric standard. However, it's not possible to know in accordance with what channel SMPS controls the constant voltage and current. In order to solve this problem, it needs to detect the maximum LED String voltage which is applied to LED control circuit, and it is possible to minimize the voltage drop when a difference of LED string voltage occurs by each channel if LED is controlled by the maximum LED string voltage detected. In addition, it is also possible to maximize the efficiency of LED if change LED voltage by detecting the maximum voltage. Feasibility of this claim was verified through implementation of the circuit.

개인용 저주파 자극기의 특성분석 및 Prototype개발 (A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis)

  • 이기송;이동하;유재택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

Ti:LiNbO3 집적광학형 파장가변 편광모드 조절기에 관한 연구 (A Study on Ti:LiNbO3 Integrated Optical Wavelength Tunable Polarization Mode Controllers)

  • 문제영;정홍식
    • 한국광학회지
    • /
    • 제16권4호
    • /
    • pp.376-383
    • /
    • 2005
  • [ $Ti:LiNbO_3$ ] 채널 광도파로와 전기광학효과를 이용하여 설계된 집적광학 파장가변 편광모드 조절기를 설계 및 제작하고, 동작특성을 측정하였다. 소자는 $TE↔TM$ 모드변환기와 TE./TM 위상변환기로 구성되었으며, Jones 매트릭스를 이용하여 각각의 전달 매트릭스를 유도하였다. 위상변환기에 의한 파장 변환율을 전산 모사하였으며, 제작된 소자의 동작 특성들을 확인하였다. 폴래리미터와 Poincare 구 좌표계를 이용하여 편광 조절기의 동작 상태를 체계적으로 측정하였다.

태양광 발전시스템을 위한 신경회로망 PID 기반 MPPT 알고리즘 (Neural PID Based MPPT Algorithm for Photovoltaic Generator System)

  • 박지호;조현철;김동완
    • 신재생에너지
    • /
    • 제8권3호
    • /
    • pp.14-22
    • /
    • 2012
  • Performance of photovoltaic (PV) generator systems relies on its operating conditions. Maximum power extracted from PV generators depends strongly on solar irradiation, load impedance, and ambient temperature. A most maximum power point tracking (MPPT) algorithm is based on a perturb and observe method and an incremental conductance method. It is well known the latter is better in terms of dynamics and tracking characteristics under condition of rapidly changing solar irradiation. However, in case of digital implementation, the latter has some error for determining a maximum power point. This paper presents a PID based MPPT algorithm for such PV systems. We use neural network technique for determining PID parameters by online learning approach. And we construct a boost converter to regulate the output voltage from PV generator system. Computer simulation is carried out to evaluate the proposed MPPT method and we accomplish comparative study with a perturb and observe based MPPT method to prove its superiority.

ITER CCU/L 컨버터의 4 상한 운전을 위한 제어의 구현 (Implementation of Control for Four quadrant Operation of ITER CCU/L Converter)

  • 박현철;김창우;이창희;박형진;조성만;오종석;서재학;최정완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.225-226
    • /
    • 2015
  • 이 논문에서는 ITER 초전도 코일 전원 장치 중 진공 용기내에 형성된 자장의 오차를 보정해주는 CCU/L 컨버터의 4 상한 운전을 위한 제어 알고리즘을 설명하고, 제어 알고리즘을 실제 컨버터에 적용하여 구현하였다. ITER CCU/L 컨버터는 4 상한 제어를 통해 영 전류 불연속 구간 없이 Correction Coil에 전압(${\pm}85V$), 전류(${\pm}10kA$)를 공급해야 하고, 이를 위해선 4 상한 운전을 위한 제어가 매우 중요하다. 4 상한 운전은 다섯 가지 모드에서 동작된다. 본 논문에서, 각 모드에 대해 설명하고, 컨버터가 각 모드에서 정상적으로 제어되는지 시뮬레이션 및 실제 시험을 통해 검증하였다.

  • PDF

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.

계통연계형 인버터 병렬운전 시 LCL 필터 상호간섭 특성 연구 (A Study for Mutual Interference of LCL Filter Under Parallel Operation of Grid-Connected Inverters)

  • 이강;서정진;차한주
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.75-81
    • /
    • 2021
  • This study analyzes the resonance characteristics caused by the mutual interference between LCL filters and the grid impedance under the parallel operation of the grid-connected inverter using the LCL filter. These characteristics are verified through simulation and experiment. Two inverters are used to connect to the grid in parallel, and the system parameters, including the LCL filter, are set to the same conditions. In the case of inverters running in parallel at the point of common coupling, the presence of grid impedance causes mutual interference between the LCL filters of each inverter, and the deviation of the filter resonance frequency is analyzed to understand the parallel inverter. The correlation between the number of devices and the size of grid impedance is simulated by PSIM and verified by MATLAB. By connecting the real-time digital simulator Typhoon HILS to the DSP 28377 control board, the mutual interference characteristics are tested under the condition of two inverters running in parallel. The experimental and analysis results are the same, indicating the validity of the analysis.

하이브리드 커패시터를 적용한 소형 태양광 전원장치 (The Small Photovoltaic power supply using Hybrid Supercapacitor)

  • 김태엽
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.826-831
    • /
    • 2019
  • 소형 독립형 태양광 전원장치는 조명장치, CCTV 등에 많이 활용되고 있다. 이러한 장치가 경쟁력을 가지기 위해서는 배터리와 같은 전력저장장치 수명이 매우 중요하다. 하이브리드 커패시터는 고밀도와 장수명의 장점을 가지고 있다. 본 논문에서는 하이브리드 커패시터를 이용한 독립형 태양광 전원장치를 제안한다. 전력변환장치의 구성하기 위해 하이브리드 커패시터의 충방전 특성 및 내부저항을 측정하였다. 일사량 변화에도 안정적인 최대 출력점 추종제어 알고리즘을 제시하였다. 제시한 시스템의 타당성을 검증하기 위해 18W의 하이브리드 커패시터와 10W태양광 전지를 이용하여 시제품을 제작하고 실험하였다.