• Title/Summary/Keyword: Convergence measurement

Search Result 1,452, Processing Time 0.029 seconds

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

The software quality measurement based on software reliability model (소프트웨어 신뢰성 모델링 기반 소프트웨어 품질 측정)

  • Jung, Hye-Jung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.45-50
    • /
    • 2019
  • This study proposes a method to measure software reliability according to software reliability measurement model to measure software reliability. The model presented in this study uses the distribution of Non - Homogeneous Poisson Process and presents a measure of the software reliability of the presented model. As a method to select a suitable software reliability growth model according to the presented model, we have studied a method of proposing an appropriate software reliability function by calculating the mean square error according to the estimated value of the reliability function according to the software failure data. In this study, we propose a reliability function to measure the software quality and suggest a method to select the software reliability function from the viewpoint of minimizing the error of the estimation value by applying the failure data.

Intra and Inter-Rater Measurement Reliability of Tibialis Anterior Muscle (TA) Thickness using the Ultrasonography Spring Gauge Technique

  • Hwang, Byeong-Hun;Jang, Tae-Jin;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.187-192
    • /
    • 2021
  • Purpose: The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness measurement of the TA using ultrasonography (US) conducted at different inward pressures of approximately 0.5 kg, 1.0 kg, and no pressure control. Methods: Twenty healthy subjects were recruited for this study. Two different examiners measured the thicknesses of the dominant TA of each subject randomly to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval, standard error of measurement, minimal detectable change, and coefficient of variance. Results: All intra-rater reliability ICC values showed high reliability above 0.9. Inter-rater reliability ICC values showed high reliability above 0.9 with 0.5 and 1.0 kg of inward pressure. In contrast, Inter-rater reliability ICC values showed poor reliability (0.23) with no pressure control of inward pressure. Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results when the muscle thickness of the TA is measured by different examiners in a clinical setting.

MULTI-POINT MEASUREMENT OF STRUCTURAL VIBRATION USING PATTERN RECOGNITION FROM CAMERA IMAGE

  • Jeon, Hyeong-Seop;Choi, Young-Chul;Park, Jin-Ho;Park, Jong-Won
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.704-711
    • /
    • 2010
  • Modal testing requires measuring the vibration of many points, for which an accelerometer, a gab sensor and laser vibrometer are generally used. Conventional modal testing requires mounting of these sensors to all measurement points in order to acquire the signals. However, this can be disadvantageous because it requires considerable measurement time and effort when there are many measurement points. In this paper, we propose a method for modal testing using a camera image. A camera can measure the vibration of many points at the same time. However, this task requires that the measurement points be classified frame by frame. While it is possible to classify the measurement points one by one, this also requires much time. Therefore, we try to classify multiple points using pattern recognition. The feasibility of the proposed method is verified by a beam experiment. The experimental results demonstrate that we can obtain good results.

3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept (순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법)

  • Park, Seong-Mi;Yang, Ji-Hoon;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system

  • Chanwoo Park;Kyu Bom Kim;Min Kyu Baek;In-soo Kang;Seongyeon Lee;Yoon Soo Chung;Heejun Chung;Yong Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1009-1014
    • /
    • 2023
  • Muon tomography is a useful method for monitoring special nuclear materials (SNMs) such as spent nuclear fuel inside dry cask storage. Multiple Coulomb scattering of muons can be used to provide information about the 3-dimensional structure and atomic number(Z) of the inner materials. Tomography using muons is less affected by the shielding material and less harmful to health than other measurement methods. We developed a muon detector for muon tomography, which consists of a plastic scintillator, 64 long wavelength-shifting (WLS) fibers attached to the top of the plastic scintillator, and silicon photomultipliers (SiPMs) connected to both ends of each WLS fiber. The muon detector can acquire X and Y positions simultaneously using a position determination algorithm. The design parameters of the muon detector were optimized using DETECT2000 and Geant4 simulations, and a muon detector prototype was built based on the results. Spatial resolution measurement was performed using simulations and experiments to evaluate the feasibility of the muon detector. The experimental results were in good agreement with the simulation results. The muon detector has been confirmed for use in a muon tomography system.

Development of Wireless Earphone Playback Time Measurement Method and Report Form (무선이어폰 재생 시간 측정 방법 및 보고 양식 개발)

  • Han, Mun-Hwan;Jeong, In-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.299-307
    • /
    • 2022
  • Wireless earphones, along with smart devices, are the most sought-after products by consumers. Compared to general earphones, wireless earphones do not have twisted wires and are easy to use, so various types of products are currently on the market. However, information on quality is somewhat lacking, so consumers tend to purchase products according to brand awareness, and manufacturers are delivering information to consumers using different standards for each product because there is no standard for quality control. In particular, the playback time of wireless earphones is a factor that directly affects consumers' purchases, so a standard measurement method is needed to properly measure it. In this paper, we present a method for measuring the audio playback time of wireless earphones derived from domestic wireless earphone status survey, commercial product measurement test, and research analysis, and a developed standard measurement method. In addition, this paper proposes a measurement result reporting format to provide accurate information to consumers and induce a fair competitive environment for each product to manufacturers.

Developing an Instruments to Measure the Convergence Talent: Building Convergence-oriented Organizations in South Korea (융합지향 조직 구축을 위한 융합인재 측정 도구 개발)

  • Lee, SeoYoung;Kwon, Sangjib
    • Knowledge Management Research
    • /
    • v.20 no.1
    • /
    • pp.77-99
    • /
    • 2019
  • This study aims to examine validity and reliability of the convergence talent measurement. Based on the comprehensive literature review on convergence and convergence talent, we draw 4 main competencies (convergence cognitive, accomplishment, problem solving, and attitude) and 10 critical aspects (creative thinking, critical thinking, cooperation, communication, problem-solving, knowledge accessibility, resource utilization, trust, openness, caring) for building an effective convergence-oriented organization. A validity and reliability test survey were conducted for the analysis to investigate the convergence talent scale. With a data of 151 employees in diverse companies, the results show that the factors demonstrated acceptable levels of validity and reliability. The empirical evidences of our study are 10 key aspects comprising four main dimensions which suggest an available scale for measuring the convergent talent for enhancing convergence-oriented organizations. Our research contributes to the expansion of academic and practical implications on convergence, especially in convergence-oriented organizations.

A Study on Effective Management for Measurement System (측정시스템의 효율적 운영에 관한 실증적 연구 - 중소제조기업(中小製造企業)을 중심(中心)으로 -)

  • Yoo, Hyun-Jong;Jun, Hyun-Jung;Yoo, Jae-Kwon
    • Journal of Industrial Convergence
    • /
    • v.1 no.2
    • /
    • pp.95-105
    • /
    • 2003
  • "All things possibly could be measured.", measurement is a essential part in all kinds of industry, especially in manufacturing. Korean Industrial Standard has been established and announced in September, 1961. Measurement has been emphasized. But until now, measurement hasn't been located to the core of manufacturing in domestic. So, this study suggests improvement guide line for the multilateral problems of measurement system based on the investigation of 146 small and medium-sized enterprises in April, 2002.

  • PDF

Design of a Smart Safety Measurement System Using Bluetooth Beacon Sensor Nodes (블루투스 비콘 센서 노드를 활용한 스마트 안전 계측 시스템 설계)

  • Park, Young-soo;Park, Chang-jin;Cho, Sun-hee;Park, Kyoung-yong;Kim, Min-sun;Seo, Jeongwook
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.126-131
    • /
    • 2017
  • This paper designs a smart safety measurement system with Bluetooth beacon sensor nodes that can provide risk detection and evacuation/countermeasure services. The Bluetooth beacon sensor nodes is easily able to be attached to old building wall or construction or civil structure with potential danger. The proposed smart safety measurement system transmits various sensor data such as acceleration, gyroscope, geomagnetic, pressure, altitude, temperature, humidity at the spot where Bluetooth beacon sensor nodes are installed, and we can use them for risk perception, prediction, and warning services. To verify the effectiveness of the proposed system, we performed filed tests which showed that measured displacement values of precast retaining walls were within the permitted displacement value of 38.5 mm.