• Title/Summary/Keyword: Convergence measurement

Search Result 1,458, Processing Time 0.031 seconds

Integer Programming Approach to the Convergence Adjustment on Color Display Tube

  • Park, Sungsoo;Kang, Donghan;Lee, Hyohyung;Hong, Cheol-Kee
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 2004
  • In this paper, we consider the adjustment of convergence on Color Display Tube (CDT). Convergence is a measure of how well the red, green and blue beams are physically aligned with each other to strike the same area on the screen. When misconvergence (convergence error) occurs, one way of compensating it is to attach several ferrite sheets on the inner part of Deflection Yoke (DY). We suggest an optimization model of misconvergence compensation process and report test results for 81 DY samples. As a result, more than 90% of the samples could be made to satisfy the required convergence criteria.

Precise Static Contact Angle Measurements Using Pythagolas Rule (피타고라스 원리를 이용한 정적 접촉각 정밀 각도 측정방법)

  • Choi, Jin-Yeong;Kwon, Dong-Jun;Wang, Zuo-Jia;Shin, Pyeong-Su;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.15 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • Pythagolas rule was used for investigation of static contact angle in particular figures. Static contact angle measurement was important to evaluate the wettability between solid and liquid. Optimum measurement method and standardization of calculation for static contact angle were investigated for practical application. Optimum diameter of droplet for static contact angle measurement was confirmed as 1 mm. Contact angle measurement using Pythagolas rule was also used to calculate advancing, receding angle and wettability of different surface condition. At last, it was concluded that the Pythagolas rule method was more accurate than general lineation method for static contact angle measurement.

Measurement Guideline of Fresnel-Field Antenna Measurement Method

  • Oh, Soon-Soo;Moon, Jung-Ick
    • ETRI Journal
    • /
    • v.31 no.1
    • /
    • pp.68-70
    • /
    • 2009
  • In this letter, a parametric analysis of the Fresnel-field antenna measurement method is performed for a square aperture. As a result, the optimum number of Fresnel fields for one far-field point is guided as $M_{opt}=N_{opt}=D^2/{\lambda}R+5$, where D is the antenna diameter, ${\lambda}$ is the wavelength, and R is the distance between the source antenna and the antenna under test. For the aperture size 5 ${\leq}$ $L_x/{\lambda}$ ${\leq}$ 20, the tolerable distances for gain errors of 0.5 dB and 0.2 dB can be guided as $R_{0.5\;dB}$ ${\approx}$ $1.2Lx/{\lambda}$ and $R_{0.2\;dB}$ ${\approx}$ $2.0L_x/{\lambda}$, where $L_x$ is the lateral length of the square aperture. The tolerable distances for 20 ${\leq}$ $L_x/{\lambda}$ ${\leq}$ 200 are also proposed. This measurement guideline can be fully utilized when performing the Fresnel-field antenna measurement method.

  • PDF

Measurement of Geometric Properties of Printed Patterns and Evaluation of their Printability (인쇄 패턴의 기하학적 특성 측정 및 인쇄성 평가)

  • Jeon, Sung Woong;Kim, Cheol;Park, Jong-Chan;Kim, Dong Soo;Kim, Chung Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.981-986
    • /
    • 2014
  • Printed electronics devices are made of several sets of printed patterns. The quality or printability of the printed patterns determines the electrical performance of such devices. Moreover, control of the printability determines the reliability of such devices. Despite its importance, few studies have been reported for the measurement of the printed patterns to evaluate their printability. In this study, a measurement method is proposed for printed patterns, including the definition of the properties to be measured, and the related software is described. The proposed method measures the width, pinholes, and edge waviness and evaluates the printability of the patterns quantitatively. The proposed measurement method could be an efficient tool to evaluate and enhance the printability of printed patterns in printed electronics.

Measurement of Elastic Constants by Simultaneously Sensing Longitudinal and Shear Waves as an Overlapped Signal

  • Seo, Hogeon;Song, Dong-Gi;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.138-148
    • /
    • 2016
  • Measurement of elastic constants is crucial for engineering aspects of predicting the behavior of materials under load as well as structural health monitoring of material degradation. Ultrasonic velocity measurement for material properties has been broadly used as a nondestructive evaluation method for material characterization. In particular, pulse-echo method has been extensively utilized as it is not only simple but also effective when only one side of the inspected objects is accessible. However, the conventional technique in this approach measures longitudinal and shear waves individually to obtain their velocities. This produces a set of two data for each measurement. This paper proposes a simultaneous sensing system of longitudinal waves and shear waves for elastic constant measurement. The proposed system senses both these waves simultaneously as a single overlapped signal, which is then analyzed to calculate both the ultrasonic velocities for obtaining elastic constants. Therefore, this system requires just half the number of data to obtain elastic constants compared to the conventional individual measurement. The results of the proposed simultaneous measurement had smaller standard deviations than those in the individual measurement. These results validate that the proposed approach improves the efficiency and reliability of ultrasonic elastic constant measurement by reducing the complexity of the measurement system, its operating procedures, and the number of data.

Measurement Range Enlargement in Brillouin Optical Correlation Domain Analysis Using Multiple Correlation Peaks

  • Jeong, Ji Ho;Lee, Kwanil;Jeong, Je-Myung;Lee, Sang Bae
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.210-214
    • /
    • 2012
  • We propose and experimentally demonstrate a method for extension of measurement range in a Brillouin optical correlation domain analysis sensor system without resolution deterioration. In the experiment, a 300 m measurement range with about 8 cm spatial resolution was successfully obtained by cascading three different kinds of fibers as a sensing element.

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

Systematic Review on the Type and Method of Convergence Study of Inertial Measurement Unit (관성 측정 장치의 융합연구 형태와 방법에 관한 체계적 고찰)

  • Lee, Hey-Sig;Park, Hae-Yean
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.119-126
    • /
    • 2020
  • The purpose of this study is to identify trends in the type and method of Inertial Measurement Unit (IMU) by investigating studies on the type and method of convergence study of the IMU by systematic review. The study was conducted using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. 23 studies that meet the selection criteria were selected from 630 studies identified by three databases. As a result of this study, showed that various research using IMU was being conducted around the world, and the type of IMU was strap, full body suit, belt, wrist watch, shoes and glove. Among them, the number of strap-type IMUs was the largest at 11. The IMU's strengths were simplicity, real-time data collection and ease of application, which were used as measurement methods such as task, walking, and range of joint. The result of this study is expected to be used as basic data for experts in the medical and rehabilitation fields that conduct IMU research.

In-situ Deposition Rate Measurement System to Improve the Accuracy of the Film Formation Process (성막 공정 정밀도 향상을 위한 실시간 성막 속도 측정 시스템)

  • Somi Park;Seung-Yo Baek;Hyun-Bin Kim;Jonghee Lee;Jae-Hyun Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.383-387
    • /
    • 2023
  • The quartz crystal microbalance (QCM), commonly used in high vacuum deposition, becomes difficult to use when a thick film is deposited on the quartz, affecting the crystal's inherent vibration. In this study, a non-destructive optical measurement method was developed to measure the film's deposition rate during the in-situ film deposition process. By measuring the scattered laser intensity caused by the dimer in the parylene gas passing through the gas flow path, it was successfully confirmed that the ratio of the dimer in the parylene gas increases as the pyrolysis temperature decreases. Additionally, it was noted that the film's thickness and haze increase as the pyrolysis temperature decreases by confirming the characteristics of the visible parylene films. Through the research results, we aim to utilize the stable in-situ film deposition rate measurement system to control the precise film deposition rate of parylene films.

Evaluation of the Functional and Non-functional Seat Sponge Effect in Sitting Chairs

  • Min, Seung Nam;Park, Se Jin;Subramaniyam, Murali;Lee, Heeran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.255-265
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate comfort levels of functional and non-functional chairs using subjective comfort rating, interface pressure measurement, muscle activity measurement, and skin temperature measurement. Background: Chairs are used for a prolonged period of time for sitting in many places such as the office, at university, at school, in industry, and so on. Almost all people use chairs in their everyday life. The functional properties of the chair are associated with comfort. Method: The subjective evaluation contains questions regarding chair comfort which can be rated with five point scale. The body-seat interface pressure was measured using a pressure mat system. The symmetry of sitting was measured using electromyography. The change in body part (thigh and buttock) temperature before and after sitting on a chair was measured with an infrared camera. Results: Participants rated significantly (p < 0.05) higher comfort scores for the functional chair in relation to the buttock and thigh region. Also, the participants felt a better cushion effect in the functional chair. When using the functional chair, lower interface pressure, better thermal comfort, and better symmetry of erector spinae muscle activity were observed. Conclusion: Overall, interface pressure measurement, muscle activity measurement, thermal imaging and subjective comfort score results showed that the functional chair was more comfortable than the non-functional chair. Application: The adopted methodologies could be used to measure the seating comfort of train seats.