• Title/Summary/Keyword: Convergence

Search Result 40,997, Processing Time 0.062 seconds

Investigation of Indicator Kriging for Evaluating Proper Rock Mass Classification based on Electrical Resistivity and RMR Correlation Analysis (RMR과 전기비저항의 상관성 해석에 기초하여 지시크리깅을 적용한 최적 암반 분류 기법 고찰)

  • Lee, Kyung-Ju;Ha, Hee-Sang;Ko, Kwang-Buem;Kim, Ji-Soo
    • Tunnel and Underground Space
    • /
    • v.19 no.5
    • /
    • pp.407-420
    • /
    • 2009
  • In this study geostatistical technique using indicator kriging was performed to evaluate the optimal rock mass classification by integrating the various geophysical information such as borehole data and geophysical data. To get the optimal kriging result, it is necessary to devise the suitable technique to integrate the hard (borehole) and soft (geophysical) data effectively. Also, the model parameters of the variogram must be determined as a priori procedure. Iterative non-linear inversion method was implemented to determine the model parameters of theoretical variogram. To verify the algorithm, behaviour of object function and precision of convergence were investigated, revealing that gradient of the range is extremely small. This algorithm for the field data was applied to a mountainous area planned for a large-scale tunneling construction. As for a soft data, resistivity information from AMT survey is incorporated with RMR information from borehole data, a sort of hard data. Finally, RMR profiles were constructed and attempted to be interpreted at the tunnel elevation and the upper 1D level.

Numerical Simulations of the local circulation in coastal area using Four-Dimensional Data Assimilation Technique (4차원 자료동화 기법을 이용한 해안가 대기 순환의 수치 실험)

  • Kim, Cheol-Hee;Song, Chang-Keun
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.2
    • /
    • pp.79-91
    • /
    • 2002
  • Four dimensional data assimilation (FDDA) technique was considered for 3 dimensional wind field in coastal area and a set of 3 numerical experiments including control experiments has been tested for the case of the synoptic weather pattern of the weak northerly geostrophic wind with the cloud amount of less than 5/10 in autumn. A three dimensional land and sea breeze model with the sea surface temperature (SST) of 290K was performed without nudging the observed wind field and surface temperature of AWS (Automatic Weather System) for the control experiment. The results of the control experiment showed that the horizontal temperature gradient across the coastline was weakly simulated so that the strength of the sea breeze in the model was much weaker than that of observed one. The experiment with only observed horizontal wind field showed that both the pattern of local change of wind direction and the times of starting and ending of the land-sea breeze were fairly well simulated. However, the horizontal wind speed and vertical motion in the convergence zone were weakly simulated. The experiment with nudgings of both the surface temperature and wind speed showed that both the pattern of local change of wind direction and the times of starting and ending of the land-sea breeze were fairly well simulated even though the ending time of the sea breeze was delayed due to oversimulated temperature gradient along the shoreline.

A Study of Home-furnishing Products Strategy through the Consumption Tendency Analysis of Single Household (1인 가구의 소비성향 분석을 통한 홈퍼니싱 제품전략 연구)

  • Kim, Taesun
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.3
    • /
    • pp.237-245
    • /
    • 2016
  • Single households currently account for 26.5% of all households and their number is expected to continue to rise, reaching 34.5% by 2035. An analysis of the consumption trends and needs of single households shows that they are rising as a new consumer group with a focus on investment on the individual and favouring: small but high-tech products: efficient use of limited resources: safety and peace of mind: self-improvement and leisure. Products which meet such demands are having an impact on the growth of home-furnishing market. An analysis of companies in Korea's home-furnishing market, with examples like the lifestyle company IKEA, shows a variety of brands such as SPA brand, furniture specialist, distributor and character products. And yet most are OEM products which lack differentiated product lines and compete with similar display and distribution structure. We needs the Single household consumption tendency of home-furnishing market and differentiation strategy through product analysis. In order to increase the value of companies in the home-furnishing market, in addition to differentiated design, product competitiveness must aspire to higher customer satisfaction with easy assembly, innovation in logistics, innovative sales methods such as virtual-reality simulation for products and space, individually-tailored furniture for the needs of single household and products which combine smart technology. For home-grown home-furnishing brands to have competitiveness, they must leverage on the strengths of the industry, offering differentiated and competitive products in a wider range of areas with convergence functions as well as differentiation in consumer interface and application of advancing technology; in-depth product research is called for.

Assessment of the Applicability of Convergence Technology for Reducing and Blocking Pollution Loads to Rivers through the Utilization of Waterfront Spaces (수변공간을 활용한 오염부하 저감 및 차단 융복합 기술의 하천 적용성 평가)

  • Kim, Bong Kyun;Seo, Dae Seuk;Oh, Jong Min;Park, Jae-Ro
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.238-246
    • /
    • 2016
  • Water purification facilities utilizing three technologies - a detention pond, an artificial wetland and an ecological revetment - were installed in waterfront spaces, including river embankments and watersides that have so far been left neglected, and then their water purification levels were analyzed in this study. The water purification facilities were found to show average removal efficiencies of 48.6% in suspended solid (SS), 30.5% in biochemical oxygen demand (BOD), 18.4% in total nitrogen (T-N) and 27.3% in total phosphorus (T-P) during rainfall. The removal efficiencies during non-rainfall were 33.2% in SS, 28.6% in BOD, 13.7% in T-N and 17.3% in T-P. These results showed that the water purification facilities using a detention pond, an artificial wetland and an ecological revetment can be used as a useful natural water purification technology in in waterfront spaces.

Fabrication and characteristics of NOx gas sensors using WO3 and In2O3 thick films to monitor air pollution

  • Son, M.W.;Choi, J.B.;Hwang, H.I.;Yoo, K.S.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.263-268
    • /
    • 2009
  • With the increasing number of automobiles, the problem of air pollution from the exhaust gases of automobiles has become a critical issue. The principal gases that cause air pollution are nitrogen oxide or NO$_x$(NO and NO$_2$), and CO. Because NO$_x$ gases cause acid rain and global warming and produce ozone(O$_3$) that leads to serious metropolitan smog from photochemical reaction, they must be detected and reduced. Mixtures of WO$_3$ and $In_2O_3$(WO$_3$:$In_2O_3$=10:0, 7:3, 5:5, 3:7, and 0:10 in wt.%), which are NO$_x$ gas-sensing materials, were prepared, and thick-film gas sensors that included a heater and a temperature sensor were fabricated. Their sensitivity to NO$_x$ was measured at 250$\sim$400$^{\circ}C$ for NO$_x$ concentrations of 1$\sim$5 ppm. The $In_2O_3$ thick-film sensor showed excellent sensitivity($R_{gas}/R_{air}$=10.22) at 300$^{\circ}C$ to 5-ppm NO. The response time for 70 % saturated sensitivity was about 3 seconds, and the sensors exhibited very fast reactivity to NO$_x$.

Preparation of Pt-, Ni- and Cr-Decorated SnO2 Tubular Nanofibers and Their Gas Sensing Properties (Pt, Ni, Cr이 도포된 튜브형 SnO2 나노섬유의 합성과 가스 감응특성)

  • Kim, Bo-Young;Lee, Chul-Soon;Park, Joon-Shik;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.211-215
    • /
    • 2014
  • The Pt-, Ni- and Cr-decorated tubular $SnO_2$ nanofibers for gas sensors were prepared by the electrospinning of polyvinylpyrrolidone (PVP) nanofibers containing Pt, Ni, and Cr precursors, the sputtering of $SnO_2$ on the electrospun PVP nanofibers, and the removal of sacrificial PVP parts by heat treatment at $600^{\circ}C$ for 2 h. Pt-decorated tubular $SnO_2$ nanofibers showed high response ($R_a/R_g=210.5$, $R_g$: resistance in gas, $R_a$: resistance in air) to 5 ppm $C_2H_5OH$ at $350^{\circ}C$ with negligible cross-responses to other interference gases (5 ppm trimethylamine, $NH_3$, HCHO, p-xylene, toluene and benzene). Cr-decorated tubular $SnO_2$nanofibers showed the selective detection of p-xylene at $400^{\circ}C$. In contrast, no significant selectivity to a specific gas was found in Ni-decorated tubular $SnO_2$ nanofibers. The selective and sensitive detection of gases using Pt-decorated and Cr-decorated tubular $SnO_2$ nanofibers were discussed in relation to the catalytic promotion of gas sensing reaction.

A Study on the Radon Concentration in the Office (사무실 내 라돈 농도에 관한 연구)

  • Choi, Hyun Woo;Kim, Chi-Nyon;Won, Jong-Uk;Kim, Hong-Kwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.334-341
    • /
    • 2016
  • Objectives: This study is aimed at examining radon exposure in offices and the factors that can influence the concentrations. Methods: Indoor radon concentrations in a total of 30 places were measured from January 18 to 21, 2016, targeting six buildings in Seoul with different completion years. The measurement was conducted according to the radon measurement guidelines for indoor air suggested by the Ministry of Environment. Results: As a result of comparing each average concentration, underground area concentration was $42.850{\pm}22.501Bq/m^3$, and that of the ground floors was $27.850{\pm}12.232Bq/m^3$, which was lower than the concentration in the underground areas and statistically significant (p=0.045). As a result of comparing the concentration according to whether or not outside air entered, the average concentration for ventilated areas was $24.876{\pm}11.833Bq/m^3$, and the average concentration for enclosed areas was $47.892{\pm}19.375Bq/m^3$. The concentration in ventilated areas was lower at a statistically significant level (p=0.001). Finally, as a result of the multiple regression analysis for evaluating the factors influencing radon concentration, only ventilation was significant (p=0.007). Conclusions: As a result of measuring radon in office buildings, there was no place that exceeding the recommended standard of the US EPA, but the concentration in poorly ventilated areas was measured to be high. An effort to manage radon concentration and reduce it through the improvement of ventilation systems, repeated measurement is necessary in the future.

Development on the Questionnaire of Cold-Heat Pattern Identification Based on Usual Symptoms for Health Promotion - Focused on Reliability Study (건강 증진을 위한 평소 증상 기반의 한열변증 설문지 개발 - 신뢰도를 중심으로)

  • Yeo, Minkyung;Park, Kihyun;Bae, Kwangho;Jang, Eunsu;Lee, Youngseop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.2
    • /
    • pp.116-123
    • /
    • 2016
  • This study was performed to develop questionnaire of cold-heat pattern identification(PI) based on usual symptoms for general people, and we analyzed reliability of the questionnaire. We reviewed cold-heat PI questionnaire of advanced research and selected twenty-three items through three time experts meeting. Three hundred and fifty nine healthy subjects were joined in this study. As a results, Cronbach's α of cold-heat PI questionnaire was 0.79 and 0.83. According to the factor analysis about fifteen-chosen cold-heat PI questionnaires, each cold-heat consisted of two factors and each Convergence was 56.46% and 65.93%. Intra-class Correlation Coefficient was 0.67-0.83. Based on the median of samples of primary source, we classified subjects into four category as Cold, Heat, No Cold-Heat, and Cold-heat complex. We examined agreement of diagnosis and coefficient of kappa, and agreement rate of diagnosis was 64.2%, and coefficient of kappa was 0.51. Based on research result, we expect that validity study about questionnaire of cold-heat PI based on usual symptoms will be continued, and hope to be used as subsidiary diagnosis in clinical practice.

Asynchronous Key Management for Energy Efficiency over Wireless Sensor Network (유비쿼터스 센서네트워크에서 에너지효율을 고려하는 비동기적인 키관리 기법)

  • Yoon, Mi-Youn
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10C
    • /
    • pp.1011-1022
    • /
    • 2006
  • WSN(Wireless Sensor Network) performs to detect and collect environmental information for one purpose. The WSN is composed of a sink node and several sensor nodes and has a constraint in an aspect of energy consumption caused by limited battery resource. So many required mechanisms in WSN should consider the remaining energy condition. To deploy WSN, tile collected information is required to protect from an adversary over the network in many cases. The security mechanism should be provided for collecting the information over the network. we propose asynchronized key management considering energy efficiency over WSN. The proposed key management is focused on independence and difference of the keys used to deliver the information over several routes over the network, so disclosure of any key does not results in exposure of total key information over the overall WSN. Also, we use hash function to update key information for energy efficiency Periodically. We define the insecurity for requested security Properties and Proof that the security properties are guaranteed. Also, we evaluate and analyze the energy efficiency for the proposed mechanism.

An Adaptive Active Noise Cancelling Model Using Wavelet Transform and M-channel Subband QMF Filter Banks (웨이브릿 변환 및 M-채널 서브밴드 QMF 필터뱅크를 이용한 적응 능동잡음제거 모델)

  • 허영대;권기룡;문광석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.89-98
    • /
    • 2000
  • This paper presents an active noise cancelling model using wavelet transform and subband filter banks based on adaptive filter. The analysis filter banks decompose input and error signals into QMF filter banks of lowpass and highpass bands. Each filter bank uses wavelet filter with dyadic tree structure. The decomposed input and error signals are iterated by adaptive filter coefficients of each subband using filtered-X LMS algorithm. The synthesis filter banks make output signal of wideband with perfect reconstruction to prepare adaptive filter output signals of each subband. The analysis and synthesis niter hants use conjugate quadrature filters for Pefect reconstruction. Also, The delayed LMS algorithm model for on-line identification of error path transfer characteristics is used gain and acoustic time delay factors. The proposed adaptive active noise cancelling modelis suggested by system retaining the computational and convergence speed advantage using wavelet subband filter banks.

  • PDF