• 제목/요약/키워드: Conventional CT

검색결과 525건 처리시간 0.029초

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

Comparison of different radiographic methods for the detection of the mandibular canal

  • Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제33권4호
    • /
    • pp.199-205
    • /
    • 2003
  • Purpose: To compare the visibility of the mandibular canal at the different radiographic methods such as conventional panoramic radiographs, Vimplant multi planar reformatting (MPR)-CT panoramic images, Vimplant MPR-CT paraxial images and film-based DentaScan MPR-CT images. Materials and Methods: Data of 11 mandibular dental implant patients, who had been planned treatment utilizing both panoramic and MPR-CT examination with DentaScan software (GE Medical systems, Milwaukee, USA), were used in this study. The archived axial CT data stored on CD-R discs were transferred to a personal computer with 17' LCD monitor. Paraxial and panoramic images were reconstructed using Vimplant software (CyberMed Inc., Seoul, Korea). Conventional panoramic radiographs, monitor-based Vimplant MPR-CT panoramic images, monitor-based Vimplant MPR-CT paraxial images, and film-based DentaScan MPR-CT images were evaluated for visibility of the mandibular canal at the mental foramen, 1 cm, 2 cm, and 3 cm posterior to mental foramen using the 4-point grading score. Results: Vimplant MPR-CT panoramic, paraxial, and DentaScan MPR-CT images revealed significantly clearer images than conventional panoramic radiographs. Particularly at the region 1 em posterior to mental foramen, conventional panoramic radiographs showed a markedly lower percentage of 'excellent' mandibular canal images than images produced by other modalites. Vimplant MPR-CT and DentaScan MPR-CT images did not show significant difference in visibility of the mandibular canal. Conclusion: The study results show that Vimplant and DentaScan MPR-CT imaging systems offer significantly better images of the mandibular canal than conventional panoramic radiograph.

  • PDF

안면부 골절 수술 전후 다중검출기 전산화 단층촬영의 효용성 비교 (Comparison of the Usefulness of MDCT (Multidetective Computed Tomogram) in Facial Bone Fractures)

  • 홍윤기;김형택
    • Journal of Trauma and Injury
    • /
    • 제19권1호
    • /
    • pp.28-34
    • /
    • 2006
  • Purpose: In maxillofacial surgery, proper preoperative diagnosis is very important in achieving good postoperative results. Although conventional CT scans are useful for visual representations of fractures, they cannot provide direct guidance for reconstructing facial bone fractures. However, the recent technology of multislice scanning has brought many clinical benefits to CT images. Direct correlations can be made between preoperative imaging data and operative planning. The aim of the current study is to evaluate the differences between conventional CT and multidetective three-dimensional CT(3D MDCT) measurements in craniofacial deformities. Methods: From January 2005 to November 2005, MDCT scans of 41 patients were evaluated by comparing them with conventional CT scans. The 3D MDCT images were assessed and reviewed by using a simple scoring system. Results: The 3D MDCT scans offered easy interpretation, facilitated surgical planning, and clarified postoperative results in malar complex fractures, mandibular fractures, and extensive maxillofacial fractures and cranioplasty. However, 3D MDCT images were not superior to conventional CT scans in the diagnosis of blowout fractures. Conclusion: In spite of its limitations, the 3D MDCT provided additional and more comprehensive information than the conventional CT for preoperative assessment of craniofacial deformities. Therefore, the 3D MDCT can be a useful tool for diagnosis and systematic treatment planning in craniofacial skeletal deformities.

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue;Takeshi Nakaura;Yasunori Nagayama;Hiroyuki Uetani;Osamu Ikeda;Yasuyuki Yamashita
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.951-958
    • /
    • 2021
  • Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.

흉, 복부 전산화 단층촬영이 정상인 외상 환자에게 척추 단순촬영이 필요한가? (Is There a Need for Conventional Spine Radiographs Following a Negative Chest and Abdominal CT in Trauma Patients?)

  • 오성찬
    • Journal of Trauma and Injury
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 2009
  • Purpose: This was conducted to assess the need for conventional radiographs of the thoracolumbar spine for routine screening of trauma patients who revealed no spinal trauma on chest and abdominal computed tomography (CT). Methods: We performed a retrospective review of the medical records of trauma patients who underwent conventional radiographs of the thoracolumbar spine following a chest and abdominal CT that revealed no spinal trauma. Results: Two hundred seventy-five trauma patients underwent conventional radiographs of the thoracolumbar spine following a chest and abdominal CT that revealed no spinal trauma. In 274 of the cases, the thoracolumbar spine series was also negative. Conclusion: CT of the chest and abdomen is an adequate evaluation of the thoracolumbar spine in trauma patients who require routine thoracolumbar spine screening, making subsequent conventional radiographs of the thoracolumbar spine unnecessary.

Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구 (Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

방사선치료용 CT simulator와 진단용 CT의 구조 차이에 의한 CT number의 비교 평가 (Evaluation of CT Number Difference between Radiation Therapeutic CT Simulator and Conventional CT)

  • 서정민;임재동;김찬형
    • 대한안전경영과학회지
    • /
    • 제17권3호
    • /
    • pp.215-219
    • /
    • 2015
  • The purpose in this study is to investigate CT number difference between conventional CT and CT simulator. It shows good correlation in CT number on the muscle, bone, and air. However, in the liver, lungs and water, the low correlation was detected. This result can become the good index for the direction of the distribution of dose difference research between CT equipment for using the computerized radiation therapy planning system.

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석 (Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method)

  • 강수홍;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교 (Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures)

  • 정종명;김종환;홍인표;최치훈
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.