• Title/Summary/Keyword: Convective condition

Search Result 171, Processing Time 0.026 seconds

Analysis of Thermal Comfort Factor′s Distribution in Convective Heating Space (대류난방공간에서 온열쾌적조건의 분포상태 분석에 관한 연구)

  • 공성훈
    • Journal of the Korean housing association
    • /
    • v.6 no.1
    • /
    • pp.31-37
    • /
    • 1995
  • The purpose of this study is to analyse the distribution of thermal sensation response and thermal environment condition in convective heating space. The contents of this study are as follows: 1)the spatial distributions of thermal conditions are measured 2)the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3)to analyse the distribution of subject's thermal sensation vote and thermal environment condition by two methods-regression method and graph method.

  • PDF

A Study on Calibration of Heat Flux Sensor by using Convective Heat Transfer (대류방식을 이용한 열유속센서의 검정에 관한 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1358-1363
    • /
    • 2004
  • The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of $1.4{\sim}2.5kW/m^2$. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ${\pm}2.07%$. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.

  • PDF

Measuring Convective Heat Transfer Coefficient Around a Heated Fine Wire in Cross Flow of Nanofluids (나노유체의 수직유동 속에 놓인 가는 열선주위의 대류열전달계수 측정)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.2
    • /
    • pp.117-124
    • /
    • 2008
  • Recent researches on nanofluids have mainly focused on the increase of thermal conductivity of nanofluids under static condition. The ultimate goal of using nanofluids, however, is to enhance the heat transfer performance under fluid flow. So it has been highly necessary to devise a simple and accurate measuring apparatus which effectively compares the heat transfer capability between the base and nanofluids. Though the convective heat transfer coefficient is not the complete index for the heat transfer capability, it might be one of useful indications of heat transfer enhancement. In this article, the working principles of experimental system for convective heat transfer coefficient around a heated fine wire in cross flow of nanofluids and its application example to three samples of nano lubrication oils are explained in detail.

Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond (소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究))

  • Pak, Ee-Tong;Seo, Ji-Weon
    • Solar Energy
    • /
    • v.7 no.2
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF

Classification of Precipitation Type Using the Wind Profiler Observations and Analysis of the Associated Synoptic Conditions: Years 2003-2005 (윈드프로파일러 관측 자료를 이용한 장마철 강수 형태 분류와 관련된 종관장의 특성 분석: 2003년-2005년)

  • Won, Hye-Yeong;Jo, Cheon-Ho;Baek, Seon-Gyun
    • Atmosphere
    • /
    • v.16 no.3
    • /
    • pp.235-246
    • /
    • 2006
  • Remote sensing techniques using satellites or the scanning weather radars depend mostly on the presence of clouds or precipitation, and leave the extensive regions of clear air unobserved. But wind profilers provide the most direct measurements of mesoscale vertical air motion in the troposphere, even in the context of heavy precipitation. In this paper, the precipitation events during the Changma period was classified into 4 precipitation types - stratiform, mixed stratiform/ convective, deep convective, and shallow convective. The parameters for the classification of analysis are the vertical structure of reflectivity, Doppler velocity, and spectral width measured with the wind profiler at Haenam for a three-year period (2003-2005). In addition, the synoptic fields and total amount of precipitation were analyzed using the Global Final Analyses (FNL) data and the Global Precipitation Climatology Project (GPCP) data. During the Changma period, the results show that the stratiform type was dominant under the moist-neutral atmosphere in 2003, whereas the deep convective type was under the moist unstable condition in 2004. The stratiform type was no less popular than the deep convective type among four seasons because the moist neutral layer was formed by the convergence between the upper-level jet and the low-level jet, and by the moisture transport along the western rim of the North Pacific subtropical anticyclone.

Two-Dimensional Laminar Natural Convection Heat Transfer with Surface Radiation in a Cavity (캐비티내에서 표면복사를 고려한 2차원 층류 자연대류 열전달)

  • Park, H.Y.;Park, K.W.;Han, C.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.217-232
    • /
    • 1992
  • A Numerical study on two-dimensional laminar natural convection with and without surface radiation in fully or partially open square cavity was performed. The cavity has one vertical heated wall facing a vertical opening and two horizontal insulated walls. The pressure boundary condition was applied to the opening instead of the velocity boundary condition. The results of this study showed that the increase of partition length decreased the convective and the radiative Nusselt numbers. It was also found that the increase of wall emissivity decreased the convective Nusselt numbers but increased the radiative Nusselt numbers.

  • PDF

Heat Transfer Characteristics of a Slot Jet and Circular Jets Impinging on a Flat Surface (벽면에 충돌하는 슬롯형 제트와 원형 제트의 열전달 효과 비교)

  • Kim, Hui-Hyun;Kim, Dae-Seong;Yoon, Soon-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.540-545
    • /
    • 2001
  • An experimental study was conducted to compare the heat transfer characteristics of an impinging slot jet and three kinds of impinging circular jets. Thermochromic liquid crystal with an image processing system was employed to measure the temperature of impinging wall where constant heat flux condition was applied. The distribution of convective heat transfer coefficients were then evaluated for eight nozzle-to-surface distance settings for each jet cases. The cooling effect was linearly proportional to the number of nozzles for circular jet cases at the same nozzle exit speed. However, the heat transfer under constant volume flow rate was the most at single circular jet. It was concluded that the overall convective heat transfer was better at the circular jets than the slot jet.

  • PDF

Estimation of elevated tanks natural period considering fluid- structure- soil interaction by using new approaches

  • Maedeh, Pouyan Abbasi;Ghanbari, Ali;Wu, Wei
    • Earthquakes and Structures
    • /
    • v.12 no.2
    • /
    • pp.145-152
    • /
    • 2017
  • The analytical method is used to develop new models for an elevated tank to estimate its natural period. The equivalent mass- spring method is used to configure the developed analytical models. Also direct method is used for numerical verification. The current study shows that developed models can have a good estimation of natural period compared with concluded results of finite elements. Additional results show that, the dependency of impulsive period to soil stiffness condition is higher than convective period. Furthermore results show that considering the fluid- structure- soil interaction has remarkable effects on natural impulsive and convective periods in case of hard to very soft soil.

New coefficients to find natural period of elevated tanks considering fluid-structure-soil interaction effects

  • Maedeh, Pouyan Abbasi;Ghanbari, Ali;Wu, Wei
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.949-963
    • /
    • 2017
  • The main purpose of the current study is to develop the new coefficients for consideration of soil-structure interaction effects to find the elevated tank natural period. Most of the recommended relations to find the natural period just assumed the fixed base condition of elevated tank systems and the soil effects on the natural period are neglected. Two different analytical systems considering soil-structure- fluid interaction effects are recommended in the current study. Achieved results of natural impulsive and convective period, concluded from mentioned models are compared with the results of a numerical model. Two different sets of new coefficients for impulsive and convective periods are developed. The values of the developed coefficients directly depend to soil stiffness values. Additional results show that the soil stiffness not only has significant effects on natural period but also it is effective on liquid sloshing wave height. Both frequency content and soil stiffness have significant effects on the values of liquid wave height.

EFFECTS OF FIN SPACING ON CONVECTIVE HEAT TRANSFER FOR A CIRCULAR CYLINDER WITH ANNULAR FINS (환상핀이 부착된 원봉에서 핀 간격에 따른 대류열전달 해석)

  • Park, Tae Seon;Kim, Chang Ha
    • Journal of computational fluids engineering
    • /
    • v.19 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to analyze the local convective heat transfer for a circular cylinder with annular fins. The relation between wall heat transfer and three-dimensional flow is investigated for different distances of annular fins. Depending on the fin spacing, the flow structure is strongly changed by the variation of horseshoe vortices. As the fin spacing increases, the heat transfer rate is maximized at a certain condition. This is clearly obtained as the Reynolds number increases, and it is closely related to the development of horseshoe vortices.