• Title/Summary/Keyword: Controller Panel

검색결과 142건 처리시간 0.025초

초고압 가스절연개폐기의 베이 컨트롤러 개발 및 성능시험 (The Development and the Performance Test of Bay Controller for the High-Voltage Gas Insulated Switchgear)

  • 우천희;이보인
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.179-184
    • /
    • 2010
  • The digital substation automation system has contributed hugely to increasing the stability of power systems by providing not only protection and control of power systems but diagnostic features alongside them. Digital substation automation systems in the scale of substations consist of integrated operation systems and intelligent electronic devices. The main intelligent electronic devices currently in use are digital protection relays and the bay controllers in Gas insulated switchgears. Proficiently accomplishing the coordination of protection within the power system as a means of ensuring reliability and contriving for the stability of power supply through connection of function, the application of bay controllers is crucial, which collectively manage the protection relay at the bay level in order to achieve both. In this research, the bay controllers to be used in high-voltage Gas insulated switchgear has been localized, and in particular, the logic function and editor required in order to minimize the complicated hardware-like cable connections in the local panel have been developed. In addition, to ensure the strength and reliability of the bay controller hardware developed herein, the type tests from KERI have been successfully completed.

대면적 비접촉 스테이지에 구동기 적용을 위한 선형유도기의 변형된 2축 벡터 제어기 (The Modified Two-axis Vector Controller of Linear Induction Motor to Apply to the Non-contact Stage with Large Workspace)

  • 정광석;이상헌
    • 제어로봇시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.385-391
    • /
    • 2008
  • To effectively cope with a complexity of kinematic metrology due to workspace enlargement of the planar stage, the linear induction motor is suggested as its new driving source. Especially, the linear induction motor under uniform plate type of secondary doesn't inherently have a periodical force ripple which is generally shown in the brushless DC motor. But, it presents a poor transient characteristic at zero or low speed zone owing to time delay of flux settling, resulting in slow response. To improve the servo property of linear induction motor and apply successfully it to the precision stage, this paper discusses a modified vector control methodology. The controller has a novel input form, fixed d-axis current, q-axis current and forward-fed DC current, to control thrust force and normal force of the linear induction motor independently. Influence of the newly introduced input and the feasibility of controller are validated experimentally.

초음파 분무 열분해 증착 제어 시스템 개발 (Development of Control System for Ultrasonic Spray Pyrolysis Deposition)

  • 김규언;김영흠;이치범
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.385-391
    • /
    • 2014
  • A control system for ultrasonic spray pyrolysis deposition was developed that can coat a large size glass panel with a transparent conductive oxide. It consists of several ultrasonic atomizer devices to cover a large area and a host computer for individually controlling the devices. The sub-controller in an ultrasonic atomizer device can adjust the flow rate of the atomized conductive oxide gas by setting the flow rate of the solution and regulating the level of the solution in the tank. To construct a feedback control loop for level regulation, a level sensor that utilized an infrared distance sensor and an electric circuit for adjusting the ultrasonic oscillator were developed. The host program was also developed, which can monitor and control the sub-controllers. A proportional-integral controller was developed for a simplified model, and its operation was verified through an experiment.

FPD를 위한 AMBA기반의 콘트라스트 컨트롤러 설계 및 구현 (Implementation and Design of AMBA based Contrast Controller for FPD)

  • 김석후;홍재인;조화현;최명렬
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 가을 학술발표논문집 Vol.30 No.2 (2)
    • /
    • pp.658-660
    • /
    • 2003
  • 본 논문에서는 AMBA 기반의 FPD 시스템에 적용 가능한 콘트라스트 컨트롤러를 설계 및 구현하였다. 제안한 콘트라스트 컨트롤러 내부에는 AMBA의 인터페이스 spec을 준수한 AMBA AHB 컨트롤러와 콘트라스트조정 블록, 메모리 컨트롤러. FPD 컨트롤러가 내장되어있다. 구현한 알고리즘은 실시간 처리가 가능하며 콘트라스트의 범위를 조정하는 가중치를 가진 알고리즘으로 기준되는 값을 이용하여 콘트라스트의 효율적인 조정이 가능하다. 콘트라스트 컨트롤러는 VHDL로 설계하였으며 FPGA를 이용한 H/W를 구현하여 TFT-LCD panel에 디스플레이 하여 검증하였다.

  • PDF

다중버스 아키텍처 구조에서 고성능 DMA를 이용한 TFT-LCD Controller 구현 (TFT-LCD Controller Implementation Using DMA of High Performance in Multi-Bus Architecture)

  • 이국표;이근환;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제45권8호
    • /
    • pp.54-60
    • /
    • 2008
  • 버스 아키텍처는 통신 전송을 만드는 마스터, 전송을 응답받는 슬레이브, 마스터를 선택하는 아비터, 그리고 버스를 연결해 주는 브리지 등으로 구성되어 있다. 이것은 최근에 좀 더 복잡해지고 있으며, 다중버스 아키텍처로 발전하고 있다. 본 논문에서는 여러 다중 shared bus 구조에 대해 논의해 보고 브리지의 레이턴시를 줄이기 위해서 메모리 셀렉터를 도입한 구조를 제안하였다. 마지막으로 이 버스구조에 DMA 마스터를 사용하는 LCD 컨트롤러를 집적하였으며, RTL 시뮬레이션과 FPGA 보드 테스트를 통하여 검증하였다. ModelSim 툴을 이용한 타이밍 시뮬레이션에서 DMA, LCD 라인버퍼, SDRAM 컨트롤러 등이 정상적으로 동작되었으며, LCD 패널이 장착된 실제 FPGA 보드에서 LCD 이미지를 확인하였다.

슈퍼 커패시터 및 태양전지를 이용한 로봇청소기용 양방향 충전시스템 설계 (Design and Implementation of a Bidirectional Power Supply Charger Using Super Capacitors and Solar Panel for Robot Cleaner Applications)

  • 정도;박성욱;권대환;구위경;김희제
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.97-102
    • /
    • 2016
  • In this paper, a bidirectional power supply charger is proposed. This system used a solar cell panel to generate electricity and used super capacitors to store these energies, which can be used for the robot cleaner or some other electronic products. This system include a phase-shift controlled bidirectional dual active bridge (DAB) converter, solar panel super capacitors and DSP controller. In the daytime it can charge to the super capacitors to store the energy generated by the solar cell panel and in the night it will release the energy stored in the super capacitors to loads. A prototype of the proposed bidirectional power supply charger system was designed which can achieve 18V to 30V input, 10V/20W output to super capacitors and 9V/6.5W output when it acts as a charger for the robot cleaner. The system is verified to be sTable and reliable by both the simulation and experimental results.

열하중을 받는 패널플러터의 궤환 선형화에 의한 비선형제어 (Nonlinear Control by Feedback Linearization for Panel Flutter at Elevated Temperature)

  • 문성환;이광주
    • 한국항공우주학회지
    • /
    • 제34권9호
    • /
    • pp.45-52
    • /
    • 2006
  • 압전재료를 사용한 복합재료 패널의 플러터 억제 방법으로서 비선형 모델을 기반으로 하는 비선형 제어기법 중의 하나인 궤환 선형화에 의한 제어방법을 소개하였다. 기존의 패널 플러터 제어기에 대한 대부분의 연구들은 선형모델을 기반으로 설계된 선형2차제어기(LQR: Linear Quadratic Regulator)였음에 비해, 본 연구에서 제안한 비선형제어기는 시스템이 갖고 있는 비선형 특성들을 모두 고려해서 설계하였다. 압전 작동기로서는 PZT를 사용하였다. 가상변위의 원리와 4절점 사각형 요소를 사용하여 이산화된 비선형 운동방정식을 유도하였으며 제어기 설계를 위해 모달 변환을 통해 상태공간에서의 비선형 연계-모달 방정식으로 변환하였다. 본 논문에서 제안한 비선형 제어기에 의한 제어 결과와 선형모델을 기반으로 한 LQR 제어결과를 Newmark 수치적분법을 통해 시간영역에서 비교하였다.

광 검출기가 장착된 OLED 조명 시스템 (OLED Lighting System Integrated with Optical Monitoring Circuit)

  • 신동균;박종운;서화일
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.13-17
    • /
    • 2013
  • In lighting system where several large-area organic light-emitting diode (OLED) lighting panels are involved, panel aging may appear differently from each other, resulting in a falling-off in lighting quality. To achieve uniform light output across large-area OLED lighting panels, we have employed an optical feedback circuit. Light output from each OLED panel is monitored by the optical feedback circuit that consists of a photodiode, I-V converter, 10-bit analogdigital converter (ADC), and comparator. A photodiode generates current by detecting OLED light from one side of the glass substrate (i.e., edge emission). Namely, the target luminance from the emission area (bottom emission) of OLED panels is monitored by current generated from the photodiode mounted on a glass edge. To this end, we need to establish a mapping table between the ADC value and the luminance of bottom emission. The reference ADC value corresponds to the target luminance of OLED panels. If the ADC value is lower or higher than the reference one (i.e., when the luminance of OLED panel is lower or higher than its target luminance), a micro controller unit (MCU) adjusts the pulse width modulation (PWM) used for the control of the power supplied to OLED panels in such a way that the ADC value obtained from optical feedback is the same as the reference one. As such, the target luminance of each individual OLED panel is unchanged. With the optical feedback circuit included in the lighting system, we have observed only 2% difference in relative intensity of neighboring OLED panels.

넓은 주파수 영역 동작의 PLL을 위한 V-I 변환기 설계 (A V-I Converter Design for Wide Range PLL)

  • 홍동희;이현석;박종욱;성만영;임신일
    • 대한전자공학회논문지SD
    • /
    • 제44권3호
    • /
    • pp.52-58
    • /
    • 2007
  • 본 논문은 FPD(Flat Panel Display)용 TCON(Timing Controller) 칩의 PLL에 관한 것이다. 최근 TCON에서는 $8\sim135MHz$의 넓은 주파수 영역 동작을 위한 PLL을 요구하고 있다. 이것을 만족시키기 위하여, 새로운 구조의 V-I 변환기 회로를 설계하였다. 새로운 구조의 V-I 변환기는 VCO의 동작 주파수 범위를 결정하는 최소/최대 전류 비율을 최대한 증가시켰고 또한 VCO의 선형성도 보장하였다. 측정 결과 $8\sim135MHz$내에서 100ps 근처의 RMS 지터을 가짐으로 FPD용 TCON칩의 IP로 적합한 특성을 가지게 되었다. 설계된 회로는 TSMC 0.25um 1-poly 3-metal CMOS 공정으로 구현하였으며, 2.5V 공급 전원에서 $8\sim135MHz$로 동작하도록 설계 하였다.

전원 전압 변화에 둔감한 PLL을 위한 V-I 변환기 설계 (A V-I Converter Design for Power Variation Insensitivity PLL)

  • 이현석;홍동희;박종욱;임신일;성만영
    • 대한전자공학회논문지SD
    • /
    • 제44권3호
    • /
    • pp.59-64
    • /
    • 2007
  • 본 논문은 FPD(Flat panel Display)용 TCON(Timing Controller) 칩의 PLL에 관한 것이다. TCON 동작 시 발생하는 전원전압 변화에 대해 일정한 주파수를 출력하도록 하는 V-I 변환기를 설계하였다 새로운 V-I 변환기는 VCO's(전압 제어 발진기)의 출력 주파수를 결정짓는 전원 전압의 변화를 그에 상응하는 전류로 보상하여 전원 전압에 둔감하게 하였다. 설계된 회로는 TSMC 0.25um 1-poly 3-metal CMOS 공정으로 구현하였으며 2.5V 공급 선원에서 $192\sim360MHz$로 동작하도록 설계 하였다. 측정 결과 $192\sim360MHz$내에서 100ps 근처의 RMS 지터을 나타내었다.