• Title/Summary/Keyword: Control of pollutant source

Search Result 126, Processing Time 0.022 seconds

An Assessment of Environmental Carrying Capacity by Analyzing the Emission and Concentration of Urban Atmospheric Pollutants (대기오염을 고려한 도시의 환경적 수용력 산정 연구)

  • Lee, Kwang-Ho;Jeong, Yeun-Woo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.517-528
    • /
    • 2011
  • Indiscreet developments cause environmental problems in major cities of Seoul Metropolitan Area. Among the environmental problems, the air pollution leads the citizens' physical and economic damages. Therefore, it needs to predict how much air pollutant which is emitted from human activities can be carried by urban environment, then to examine the reasonable level of urban development This study assumed that the air pollution is represented differently by the amount of emission. With the assumption, the acceptable air pollutant emission which keeps the air quality under the environmental standard is estimated, then the proper population is calculated in the case of Gwacheon, Gyeonggi. The result is as follow: First, air pollution concentrations of CO, $NO_2$, $SO_2$ which are estimated by using IDW interpolation of GIS don't excess the air environmental standard. Second, the result of correlation analysis between air pollutant emission and air pollution concentration shows that CO and $NO_2$ has high correlationship with total source of pollution and linear source of pollution, and $SO_2$ with linear source of pollution. Third, the results of regression analysis show that the acceptable population is bigger that the real population in the case of CO, and with the estimation of $NO_2$ and $SO_2$, the current population in the urban center and boundaries where the residential and commerce land uses are concentrated is bigger than the acceptable population. The consequence of this study is that the estimation of carrying capacity can suggest the acceptable human activities which keep the air quality under the environmental standard. This can leads the sustainable urban development by control the human activities under the carrying capacity of urban environment.

Biodegradable Check Dam and Synthetic Polymer, its Experimental Evaluation for Turbidity Control of Agricultural Drainage Water

  • Kim, Minyoung;Kim, Seounghee;Kim, Jinoh;Lee, Sangbong;Kim, Youngjin;Cho, Yongho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.458-462
    • /
    • 2013
  • A drainage ditch is normally a component of drainage networks in farming systems to remove surplus water, but at the same time, it may act as a major conduit of agricultural nonpoint source pollutions such as sediment, nitrogen, phosphorus, and so on. The hybrid turbidity reduction system using biodegradable check dam and synthetic polymer was developed in this study to manage pollutant discharge from agricultural farmlands during rainfall events and/or irrigation periods. The performance of this hybrid system was assessed using a laboratory open channel sized in 10m-length and 0.2m-width. Various check dams using agricultural byproducts (e.g., rice straw, rice husks, coconut fiber and a mixture of rice husks and coconut fiber) were tested and additional physical factors (e.g., channel slope, flowrate, PAM dosage, turbidity level, etc.) affecting on turbidity reduction were applied to assess their performance. A series of lab experiments clearly showed that the hybrid turbidity reduction system could play a significant role as a supplementary of Best Management Practice (BMP). Moreover, the findings of this study could facilitate to develop an advanced BMP for minimizing nonpoint source pollution from agricultural farmlands and ultimately to achieve the sustainable agriculture.

Real-time automated detection of construction noise sources based on convolutional neural networks

  • Jung, Seunghoon;Kang, Hyuna;Hong, Juwon;Hong, Taehoon;Lee, Minhyun;Kim, Jimin
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.455-462
    • /
    • 2020
  • Noise which is unwanted sound is a serious pollutant that can affect human health, as well as the working and living environment if exposed to humans. However, current noise management on the construction project is generally conducted after the noise exceeds the regulation standard, which increases the conflicts with inhabitants near the construction site and threats to the safety and productivity of construction workers. To overcome the limitations of the current noise management methods, the activities of construction equipment which is the main source of construction noise need to be managed throughout the construction period in real-time. Therefore, this paper proposed a framework for automatically detecting noise sources in construction sites in real-time based on convolutional neural networks (CNNs) according to the following four steps: (i) Step 1: Definition of the noise sources; (ii) Step 2: Data preparation; (iii) Step 3: Noise source classification using the audio CNN; and (iv) Step 4: Noise source detection using the visual CNN. The short-time Fourier transform (STFT) and temporal image processing are used to contain temporal features of the audio and visual data. In addition, the AlexNet and You Only Look Once v3 (YOLOv3) algorithms have been adopted to classify and detect the noise sources in real-time. As a result, the proposed framework is expected to immediately find construction activities as current noise sources on the video of the construction site. The proposed framework could be helpful for environmental construction managers to efficiently identify and control the noise by automatically detecting the noise sources among many activities carried out by various types of construction equipment. Thereby, not only conflicts between inhabitants and construction companies caused by construction noise can be prevented, but also the noise-related health risks and productivity degradation for construction workers and inhabitants near the construction site can be minimized.

  • PDF

Runoff Characteristics of Non-Point Sources on the Stormwater (강우에 의한 도로 비점오염원 유출 특성)

  • Kim, Seog-Ku;Kim, Young-Im;Kang, Sung-Won;Yun, Sang-Leen;Kim, So-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.104-110
    • /
    • 2006
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Accordingly, release of contaminants from non-point sources, released with surface runoff of rainwater, is influenced by atmospheric phenomena, geology, and topography. This makes the control of non-point source difficult. Therefore, this study intends to reveal the characteristics of runoff and particle size distribution to observe the fundamental characteristics of runoff. Experiments were carried out at inner road of research center. Average concentration of runoff ranged from 26.8 to 126.4 mg/L for SS and $COD_{Cr}\;15.3{\sim}117.7mg/L,\;TN\;0.07{\sim}5.16mg/L,\;TP\;0.06{\sim}0.49mg/L$ and heavy metals $0.00{\sim}0.29mg/L$. First flush, indicated wash off of pollutant at first rain, was observed for all types of pollutants. Most pollutants revealed a very close correlation with SS ($R^2=0.93{\sim}0.99$). After analyzing characteristics of particle, particle was finer than that from previously examined data.

Decision of Critical Area Due to NPS Pollutant Loadings from Kyongan Stream Watershed using BASINS-SWAT (BASINS-SWAT 모델을 이용한 경안천 유역의 비점원 오염배출 중점관리 대상지역 결정)

  • Jang, Jae-Ho;Yoon, Chung-Gyeong;Jung, Kwang-Wook;Son, Yeung-Kwon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.69-78
    • /
    • 2009
  • In order to improve water quality of upper watershed of Paldang reservoir, it is necessary to evaluate non-point source pollution loads and identify critical watershed pollution sources. A GIS based Soil and Water Assessment Tool was applied to evaluate model application and reliability, estimate NPS pollution load, identify critical watershed by NPS pollution sources, and suggest various best management practices for Kyongan Stream watershed. Yearly NPS pollution loads were estimated 30.0% SS, 60.1% TN and 35.4% TP, respectably. The watershed pollution load is mainly decided by precipitation condition and SS and nutrients load have a significant regression relationship. Based on 10-year average yearly NPS pollution load, critical sub-watersheds were identified. The No. 5 and 17 which have lots of relatively intensive agricultural fields and scattered industrial area were vary critical sub-watersheds and under more intensive pollution load. In order to control critical watershed, watershed best management practices such as scientific fertilizer, contour farming and parallel terrace, transferring the sloppy farmland to grass or forest and constructing a buffer zone, and constructing wetlands and retention ponds will be applied. Overall the SWAT model can be efficiently used for identification of critical sub-watersheds in order to develop a priority watershed management plan to reduce water pollutions.

A Study on the Estimation of Air Pollutants Emission Factors in Electric Power Plants (화력발전소의 대기오염물질 배출계수 산정 연구)

  • 김대곤;엄윤성;홍지형;이석조;석광설;이대균;이은정;방선애
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.281-290
    • /
    • 2004
  • The main purpose of this study was to characterize the air pollutants emission factors in electric power plant (EPP) using fossil fuels. The electric power plant is a major air pollution source, thus knowing the emission characteristics of electric power plant is very important to develop a control strategy. The major air pollutants of concern from EPP slacks are particulate matter (PM), sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO) and heavy metals. Throughout the study, the following results are estimated - PM : 8.671E-05 ∼ 8.724E+01 PM emission (kg) per fuel burned (ton) - SOx : 4.149E-04∼7.877E+01 SOx emission (kg) per fuel burned (ton) - NOx 1.578E-02∼9.857E+00 NOx emission (kg) per fuel burned (ton) - CO : 3.800E-04∼1.291E+00 CO emission (kg) per fuel burned (ton) - Hg : 1.220E+01∼3.108E+02 Hg emission (mg) per fuel burned(ton) From the statistical analysis by Wilcoxon signed ranks test between the emission factors of ours and U.S. EPA's, we can yielded that : p 〉0.05.

Water Quality Prediction and Forecast of Pollution Source in Namgang Mid-watershed each Reduction Scenario (남강중권역 오염부하 전망 및 삭감 시나리오별 하류 수질예측)

  • Yu, Jae Jeong;Shin, Suk Ho;Yoon, Young Sam;Kang, Doo Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.4
    • /
    • pp.543-552
    • /
    • 2012
  • Namgang mid-watershed is located in downstream of Nakdong river basin. There are many pollution sources arround this area and it's control is important to manage a water quality of Nakdong river. A target year of Namgang mid-watershed water environment management plan is 2013. To predict a water quality at downstream of Namgang, we have investigated and forecasted the pollutant source and it's loading. There are some plan to construction the sewage treatment plants to improve the water quality of Nam river. Those are considered on predicting water quality. As results, it is shown that the population is 343,326 and sewerage supply rate is 79.2% and the livestock is 1,662,000 in Namgang mid-watershed. It is estimated that the population is 333,980, the sewerage supply rate is 86.9% in 2013. The milk cow and cattle were estimated upward and the pigs were downward by 2013. The generated loading of BOD and TP is 75,957 kg/day and 4,311 kg/day, discharged loading is 18,481 kg/day and 988 kg/day respectively in 2006. It were predicted upward the discharged loading of BOD and TP by 4.08% and 6.3% respectively. The results of water quality prediction of Namgang4 site were 2.5 mg/L of BOD and 0.120 mg/L of TP in 2013. It is over the target water quality at that site in 2015 about 25.0% and 9.1% respectively. Consequently, there need another counterplan to reduce the pollutants in that mid-watershed.

Simulation of 10-day Irrigation Water Quality Using SWAT-QUALKO2 Linkage Model (SWAT-QUALKO2 연계 모형을 이용한 관개기 순별 관개수질 모의)

  • Kim, Ji Hye;Jeong, Han Seok;Kang, Moon Seong;Song, In Hong;Park, Seung Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.53-63
    • /
    • 2012
  • The objectives of this study were to develop a linked watershed-waterbody modeling system and to assess the impacts of indirect wastewater reuse on irrigation water quality. The Osan stream watershed within Gyeonggi-do of South Korea was selected for this study. The linked modeling system was composed of the SWAT (Soil and water assessment tool) and QUALKO2 models. The SWAT model was calibrated and validated using the stream discharge and water quality data from 2010 to 2011. Runoff and non-point source pollutants from each subbasin and stream discharge from 1980 to 2009 were simulated by the SWAT model and applied to the QUALKO2 model. The QUALKO2 model was calibrated and validated under the conditions of low water and normal discharges, respectively. Finally, The 10-day irrigation water quality from April to September was simulated. The statistical measures of coefficient of determination ($R^2$), reliability index (RI), and efficiency index (EI) were used to evaluate the system performance. The $R^2$, RI and EI values ranged from 0.5 to 1.0, 1.03 to 1.92, and -35.03 to 0.95, respectively. The 10-day irrigation water quality showed the concentrations of BOD and coliform exceeded the water quality guidelines for wastewater reuse. The linked modeling system can be a useful tool to estimate non-point source pollutant loads in watershed and to control the water quality of effluent from a wastewater treatment plant and irrigation water in the downstream waterbody.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

Development of Integrated Management System of Stormwater Retention and Treatment in Waterside Land for Urban Stream Environment (도시 하천 환경 관리를 위한 제외지 초기 강우 처리 및 저류 시설 종합 관리 시스템 개발)

  • Yin, Zhenhao;Koo, Youngmin;Lee, Eunhyoung;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.126-135
    • /
    • 2015
  • Increase of delivery effect of pollutant loads and surface runoff due to urbanization of catchment area results in serious environmental problems in receiving urban streams. This study aims to develop integrated stormwater management system to assist efficient urban stream flow and water quality control using information from the Storm Water Management Model (SWMM), real time water level and quality monitoring system and remote or automatic treatment facility control system. Based on field observations in the study site, most of the pollutant loads are flushed within 4 hours of the rainfall event. SWMM simulation results indicates that the treatment system can store up to 6 mm of cumulative rainfall in the study catchment area, and this means any type of normal rainfall situation can be treated using the system. Relationship between rainfall amount and fill time were developed for various rainfall duration for operation of stormwater treatment system in this study. This study can further provide inputs of river water quality model and thus can effectively assist integrated water resources management in urban catchment and streams.