• 제목/요약/키워드: Control of Cracking

검색결과 352건 처리시간 0.025초

차수벽 콘크리트의 균열제어 및 성능향상에 관한 연구 (Control of Crack and Enhanced Durability Performance of Face Slab Concrete)

  • 임정열;정우성;김완영;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.537-540
    • /
    • 2003
  • The effects of substituting cement with fly ash(10%, 15%, 20%) and different fiber addition(polypropylene, cellulose, poly vinyl alcohol), on the control of microcrack and enhanced durability performance of face slab concrete in CFRD was studied experimentally It was conducted experiments of plastic shrinkage of mortar and concrete, and drying shrinkage of concrete. Also, durability test were carried out the chloride permeability, abrasion resistance and freeze-thaw repetition. Through the experimental results, it was concluded that ploy vinyl alcohol fiber containing concrete was the most effective mixture in control of cracking and durability.

  • PDF

Study to detect bond degradation in reinforced concrete beams using ultrasonic pulse velocity test method

  • Saleem, Muhammad
    • Structural Engineering and Mechanics
    • /
    • 제64권4호
    • /
    • pp.427-436
    • /
    • 2017
  • Concrete technologists have used ultrasonic pulse velocity test for decades to evaluate the properties of concrete. However, the presented research work focuses on the use of ultrasonic pulse velocity test to study the degradation in steel-concrete bond subjected to increasing loading. A detailed experimental investigation was conducted by testing five identical beam specimens under increasing loading. The loading was increased from zero till failure in equal increments. From the experimentation, it was found that as the reinforced concrete beams were stressed from control unloaded condition till complete failure, the propagating ultrasonic wave velocity reduced. This reduction in wave velocity is attributed to the initiation, development, and propagation of internal cracking in the concrete surrounding the steel reinforcement. Using both direct and semidirect methods of testing, results of reduction in wave velocity with evidence of internal cracking at steel-concrete interface are presented. From the presented results and discussion, it can be concluded that the UPV test method can be successfully employed to identify zones of poor bonding along the length of reinforced concrete beam. The information gathered by such testing can be used by engineers for localizing repairs thereby leading to saving of time, labor and cost of repairs. Furthermore, the implementation strategy along with real-world challenges associated with the application of the proposed technique and area of future development have also been presented.

Numerical simulation of columns with un-bonded reinforcing bars for crack control

  • Chen, G.;Fukuyama, H.;Teshigawara, M.;Etoh, H.;Kusunoki, K.;Suwada, H.
    • Structural Engineering and Mechanics
    • /
    • 제26권4호
    • /
    • pp.409-426
    • /
    • 2007
  • Following previous work carried out in Building Research Institute in Japan, finite element analyses of conceptual column designs are performed in this paper. The effectiveness of the numerical model is evaluated by experimental tests and parametric studies are conducted to determine influential factors in conceptual column designs. First, three different column designs are analysed: bonded, un-bonded, and un-bonded with additional reinforcing bars. The load-displacement curves and cracking patterns in concrete are obtained and compared with experimental ones. The comparisons indicate that the finite element model is able to reflect the experimental results closely. Both numerical and experimental results show that, the introduction of un-bonded zones in a column end can reduce cracking strains, accordingly reduce the stiffness and strength as well; the addition of extra reinforcement in the un-bonded zones can offset the losses of the stiffness and strength. To decide the proper length of the un-bonded zones and the sufficient amount of the additional reinforcing bars, parametric studies are carried out on their influences. It has been found that the stiffness of un-bonded designs slightly decreases with increasing the length of the un-bonded zones and increases with the size of the additional reinforcing bars.

VES-LMC의 열 특성을 고려한 자기수축 (Autogenous Shrinkage of VES-LMC considering Hydration-Heat)

  • 최판길;이봉학
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.73-80
    • /
    • 2005
  • Durability of concrete structures is seriously compromised by cracking at early-age concretes, particularly in high-strength or high-performance concrete structures. Since early-age cracking is influenced by various factors that affect the hydration process, early-age shrinkage and stress/strain development, the behavior at early-age is highly complex and no rational methodologies for its control have yet been established. Concrete structures often present volumetrical changes particularly due to thermal and moisture related shrinkages. Volumetric instability is detrimental to the performance and durability of concrete structures because structural elements are usually restrained. These restrained shrinkages develope tensile stresses which often results in cracking in combination with the low fracture resistance of concrete. Early-age defects in high-performance concrete due to thermal and autogenous deformation shorten the life cycle of concrete structures. Thus, it is necessary to examine the behavior of early-age concrete at the stages of design and construction. The purpose of this study was to propose a shrinkage models of VES-LMC (very-early strength latex-modified concrete) at early-age considering thermal deformation and autogenous shrinkage.

  • PDF

SP-SSRT법에 의한 TMCP강 용접부의 응력부식균열 평가에 관한 연구 (A Study on the Stress Corrosion Cracking Evaluation for Weld Joint of TMCP steel by SP-SSRT Method)

  • 유효선;정희돈;정세희
    • Journal of Welding and Joining
    • /
    • 제15권1호
    • /
    • pp.46-54
    • /
    • 1997
  • The object of this paper is to evaluate SCC(stress corrosion cracking) susceptibility for parent metal and bond line region of weld joints which have the various weld heat input condtions in TMCP(thermo-mechanical control process) steel by SP-SSRT(small punch-slow strain rate test) method. And the SCC test results of TMCP steel are compared with those of the conventional HT50 steel which has te almost same tensile strength level like TMCP steel. The loading rate used was $3\times10^{-4}$mm/min and the corrosive environment was synthetic sea water. According to the test results, in the case of parent metal, TMCP steel showed higher SCC susceptibility than HT50 steel because of the high plastic strain level of ferrite microstructure obtained by accelerated cooling. And in the case of bond line, the both TMCP steel and HT50 steel showed low load-displacement behaviors and higher SCC susceptibility above 0.6. These results may be caused by theembrittled martensite structure on HT50 steel and by the coarsened grain and the proeutectoid ferrite structure obtained by the impart of accelerated cooling effect on TMCP steel.

  • PDF

ROLE OF GRAIN BOUNDARY CARBIDES IN CRACKING BEHAVIOR OF Ni BASE ALLOYS

  • Hwang, Seong Sik;Lim, Yun Soo;Kim, Sung Woo;Kim, Dong Jin;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.73-80
    • /
    • 2013
  • The primary water stress corrosion cracking (PWSCC) of Alloy 600 in a PWR has been reported in the control rod drive mechanism (CRDM), pressurizer instrumentation, and the pressurizer heater sleeves. Recently, two cases of boric acid precipitation that indicated leaking of the primary cooling water were reported on the bottom head surface of steam generators (SG) in Korea. The PWSCC resistance of Ni base alloys which have intergranular carbides is higher than those which have intragranular carbides. Conversely, in oxidized acidic solutions like sodium sulfate or sodium tetrathionate solutions, the Ni base alloys with a lot of carbides at the grain boundaries and shows less stress corrosion cracking (SCC) resistance. The role of grain boundary carbides in SCC behavior of Ni base alloys was evaluated and effect of intergranular carbides on the SCC susceptibility were reviewed from the literature.

교량교대구조물의 수화열 및 온도응력에 대한 실험적 연구 (An Experimental study on the Thermal Stresses in the Massive Abutment of Bridge)

  • 권기준;김동백
    • 한국방재학회 논문집
    • /
    • 제6권2호
    • /
    • pp.1-7
    • /
    • 2006
  • 콘크리트 댐, 원자력발전소 및 항만구조물등의 대형구조물을 시공하기 위해서는 짧은 기간에 막대한 양의 콘크리트를 타설하게 된다. 매스콘크리트 구조물을 시공하는 단계에서 발생되는 수화열은 심각한 온도균열을 발생시켜 본래의 기능수행능력과 사용수명에 있어서 심각한 저하를 초래할 수 있다. 본 연구에서는 매스콘크리트 구조물의 대표적인 예라고 할 수 있는 교대구조물에 대하여 수화열 및 온도응력을 사전해석하고 그 결과를 바탕으로 구조물 성능확보를 위한 온도균열제어대책을 제시하였으며, 제시된 대책을 바탕으로 이루어진 시공현장에서 교대기초부 및 본체부에서의 온도분포와 응력을 계측하고 온도균열 발생양상을 관찰하여 제시된 대책의 타당성을 단계별로 확인하였다.

압출성형 ECC 패널을 이용한 RC슬래브의 균열제어성능 (Crack Control Performance of the RC Composite Slabs Produced with Extruded ECC Panel)

  • 김윤용;이정한;조창근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.95-96
    • /
    • 2010
  • 이 연구는 압출 성형한 ECC 패널과 철근콘크리트로 구성된 합성 슬래브의 균열제어성능을 평가하고 있다. 이를 위하여 ECC를 압출 성형하여 패널로 제작한 후, 그 패널에 현장타설 콘크리트를 일체 타설하여 실규모의 1방향 슬래브를 제작하였고, 그 실험체에 대하여 휨 실험을 수행하였다.

  • PDF

석유정제산업 공정과 공정장비에 기인한 휘발성 유해 대기오염물질(HAPs)의 배출량 산정기법 (Estimation Technique of Volatile Hazardous Air Pollutants(HAPs) Emitted from Petroleum Industrial Process/Equipment)

  • 조완근;권기동;동종인;강경희
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.703-710
    • /
    • 2004
  • Petroleum refineries have been considered as an important emission source for atmospheric volatile hazardous air pollutants(HAPs). The emission source includes petroleum refinery processes and process equipment. The control strategy for volatile HAPs requires emission estimations of these pollutants. However, systematic methods of volatile HAPs emission from petroleum refineries have not yet been established. Accordingly, present study surveyed the estimation method of volatile HAPs emitted from the petroleum refinery processes and process equipment. The emission estimation methods for the petroleum refinery processes are applied for 11 petroleum refining facilities: fluidized catalytic cracking, thermal cracking, moving bed catalytic cracking, compressed engine, blowdown system, vacuum distilled column condensator, natural gas or distilled boiler, natural gas or distilled heater, oil boiler, oil heater and flare. Four emission estimation methods applied for the petroleum refinery process equipment are as follows: average emission factor approach, screening ranges approach, EPA correlation approach and unit-specific correlation approach. The process equipment for which emission factors are available are valves, pump seals, connectors, flanges and open-ended lines.

부식에 의한 부착저항감소를 고려한 콘크리트 교량의 균열폭 예측 (Crack Width Prediction in Concrete Bridges Considering Bond Resistances affected by Corrosion)

  • 조태준;조효남;박미연
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.543-552
    • /
    • 2006
  • 사용성 한계상태로서의 균열폭 예측에 관한 현재의 교량설계 시방기준은, 부식의 시작과 진행에 의한 균열폭을 고려할 때 이론적으로 불충분하다. 균열폭은 하중, 부착, 미끄러짐, 그리고 철근이나 긴장재의 부식에 영향을 받게 된다. 콘크리트 교량의 생애주기 동안의 시간 의존적 일반부식을 고려하여, 균열폭 예측식을 제안하였다. 개발된 부식모델과 균열예측식은 프리스트레스트 콘크리트교량과 일반콘크리트교량의 설계시 시간단계별로 물-시멘트 비, 피복두께, 단면형상의 변화에 따른 극한한계상태와 사용성한계상태의 평가에 사용될 수 있다. 또한 기존교량의 시간단계별 극한 한계상태 및 사용성한계 상태의 평가를 통해서 정량적인 유지관리 및 잔존수명예측에 기여할 것으로 기대한다.