• 제목/요약/키워드: Control flow errors

검색결과 92건 처리시간 0.028초

HSPF 유역모델을 이용한 낙동강유역 실시간 수문 유출 예측 (Operational Hydrological Forecast for the Nakdong River Basin Using HSPF Watershed Model)

  • 신창민;나은혜;이은정;김덕길;민중혁
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.212-222
    • /
    • 2013
  • A watershed model was constructed using Hydrological Simulation Program Fortran to quantitatively predict the stream flows at major tributaries of Nakdong River basin, Korea. The entire basin was divided into 32 segments to effectively account for spatial variations in meteorological data and land segment parameter values of each tributary. The model was calibrated at ten tributaries including main stream of the river for a three-year period (2008 to 2010). The deviation values (Dv) of runoff volumes for operational stream flow forecasting for a six month period (2012.1.2 to 2012.6.29) at the ten tributaries ranged from -38.1 to 23.6%, which is on average 7.8% higher than those of runoff volumes for model calibration (-12.5 to 8.2%). The increased prediction errors were mainly from the uncertainties of numerical weather prediction modeling; nevertheless the stream flow forecasting results presented in this study were in a good agreement with the measured data.

광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정 (Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor)

  • 고재일;정인철;이동희;박신우;황성오;박소미;김기연;주현실;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

박격포 포신 제작을 위한 Inconel718 소재의 전진 유동성형 조건 선정에 관한 연구 (A Study on the Selection of Forward Flow Forming Conditions with Inconel718 Tube for Mortar Barrel Manufacturing)

  • 고세권;조영태
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.51-59
    • /
    • 2019
  • Flow forming is an eco-friendly and high-efficiency plastic deformation process with fewer chips during a process which is specifically used to manufacture seamless tubular products like tire wheels, rocket motor cases etc. On the development of mortar barrel using Inconel718 tube, some flow formed products had dimensional errors on their thickness. In this study, our purpose is to optimize the process conditions with the smallest dimensional error. In order to find an optimum process condition, 2D axisymmetric FEM simulation analyses with Taguchi method were conducted. Geometric variables (attack angle, flatting angle, roller nose radius) and operating parameters (depth of forming, feed rate) are considered as control factors. Forward flow forming with single roller was first analyzed to determine the effective factors using AFDEX software and attack angle of the roller was identified as the most influential factor. Also, the nose radius of the rollers was confirmed as a significant factor in multi-rollers flow forming system. The effect of rollers offset values are also studied and finally, we proposed optimal conditions to improve the accuracy of flow forming process with Inconel718 tube for mortar barrel manufacturing.

액체로켓 엔진 성능 보정용 제어밸브의 고유유량특성 계산 (Evaluation of the Inherent Flow Coefficient of the Control Valve in the Liquid Propellant Rocket Engine)

  • 박순영;조원국;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.585-589
    • /
    • 2010
  • 액체로켓 엔진이 발사체의 추력원으로써 임무를 성공적으로 완수하기 위해서는 주어진 성능 요구조건을 충실히 만족시킬 수 있어야 한다. 가스발생기 사이클 엔진의 경우 엔진을 구성하는 각 구성품들의 성능 분산을 보정하는 지상 시험을 거치게 되며, 이때 보정용 제어밸브를 이용하여 추력이나 혼합비 등의 엔진 성능을 요구수준 이내로 보정하게 된다. 이러한 보정용 제어밸브의 고유유량특성(Inherent Flow Characteristics)을 제어 대상값과 선형적인 관계를 가지도록 선정함으로써 보정 과정을 간단하면서도 예측가능한 형태로 가져갈 수 있다. 이에 본 연구에서는 기존에 개발된 엔진 모드해석 프로그램을 응용하여 추력 및 혼합비 보정용 제어밸브의 고유유량특성을 계산하기 위한 알고리즘을 제안하고, 실제 엔진의 작동 모드를 계산하였다.

  • PDF

소하천수계의 단위유량도 유도 및 비교에 관한 수문학적 고찰 (Hydrological Studies on the Comparison and the Derivation of Unit Hydrography in the small River Systems.)

  • 이순혁
    • 한국농공학회지
    • /
    • 제20권3호
    • /
    • pp.4739-4749
    • /
    • 1978
  • This studies were conducted to derive synthetic unitgraphs and triangular unitgraphs correlated with watershed characteristics which can be used to the estimation and control of flood for the rational development of Agricultural water resources. Derived Synthetic unitgraphs and Triangular unitgraphs can be applied to the ungaged watersheds were compared with average unitgraphs by observed data. Seven small watersheds were selected as studying basins Han, Geum, Nakdong, Yeongsan and Inchon river system. The results summarized for these studies are as follows: 1. Average unitgraphs by observed data and dimensionless unitgraphs for synthesis were derived for all river systems. 2. Peak discharge per unit area of the unitgraph, qp, was derived as qp=10-0.389-0.0424Lg with a high significance. 3. Formulas for the base width of unitgraph of 50 and 75 percent for peak flow for each water systems was adopted as Table 5. 4. The base length of the unitgraph, Tb, in hours in connection with time to peak, Tp, in hours was expressed as Tb =4.3Tp. 5. Peak discharge, Qp, were obtained as Table 6 by the Triangular form to all subwatersheds. 6. Relative errors in the peak discharge of the synthetic unitgraphs showed to be 7.3 percent to the peak of observed average unitgraphs except errors of peak discharge for Yeongsan river system. This indicates that Synthetic unitgraphs for the small watersheds of Han, Geum, Nakdong and Inchon river systems can be applied to the ungaged watersheds. On the other hand, It was confirmed that the accuracy of Instantaneous Unit Hydrograph with only 1.6 percent as relative errors was approaching more closely to the observed average unitgraph than that of synthetic unitgraph with relative errors. 23.9 percent for Yeongsan river system. 7. Errors in the peak discharge of the triangular unitgraph to the observed average unitgraph showed to be 0.6 percent to 7.5 percent which can be regarded as a high precision within the range of 200 to 500$\textrm{km}^2$ in area. On the contrary, application of triangular unitgraph within the range of 200$\textrm{km}^2$ in area has defined as a unsuitable method because of high relative errors, 26.4 percent to 61.6 percent.

  • PDF

고진공 운송계에서의 정밀 압력제어장치의 설게 및 성능시험 (Design and Performance Evaluation of the Precision Pressure Control System for the High Vacuum Transport Module)

  • Jang, W.I.;Jang, K.H.;Lee, J.H.
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.92-98
    • /
    • 1995
  • In the cluster tool, it is necessary to precisely control the vacuum pressure for the wafer transportation between transport module and cassette or process modules with the range of 1*10$^{-4}$ to 5*10$^{-5}$ torr. So we have designed the pressure control system for the transport module of the cluster tool and have evaluated its performance. Digital PID is utilized with the weighted sum of both three previous errors and one current error. The feedback signal is put into the nitrogen mass flow controller using the transport module controller. This pressure control system can prevent the transport module from the particle generation and backstreaming of hazardous process gases of the process chamber.

  • PDF

계층성을 이용한 VHDL 행위 수준에서의 설계 오류 탐색 알고리듬 (Design Error Searching Algorithm in VHDL Behavioral-level using Hierarchy)

  • 윤성욱;정현권김진주김동욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.1013-1016
    • /
    • 1998
  • A method for generation of design verification tests from behavior-level VHDL program is presented. Behavioral VHDL programs contain multiple communicating processes, signal assignment statements. So for large, complex system, it is difficult problem to test or simulation. In this paper, we proposed a new hardware design verification method. For this method generates control flow graph(CFG.) and process modeling graph(PMG) in the given under the testing VHDL program. And this method proved very effective that all the assumed design errors could be detected.

  • PDF

A water treatment case study for quantifying model performance with multilevel flow modeling

  • Nielsen, Emil K.;Bram, Mads V.;Frutiger, Jerome;Sin, Gurkan;Lind, Morten
    • Nuclear Engineering and Technology
    • /
    • 제50권4호
    • /
    • pp.532-541
    • /
    • 2018
  • Decision support systems are a key focus of research on developing control rooms to aid operators in making reliable decisions and reducing incidents caused by human errors. For this purpose, models of complex systems can be developed to diagnose causes or consequences for specific alarms. Models applied in safety systems of complex and safety-critical systems require rigorous and reliable model building and testing. Multilevel flow modeling is a qualitative and discrete method for diagnosing faults and has previously only been validated by subjective and qualitative means. To ensure reliability during operation, this work aims to synthesize a procedure to measure model performance according to diagnostic requirements. A simple procedure is proposed for validating and evaluating the concept of multilevel flow modeling. For this purpose, expert statements, dynamic process simulations, and pilot plant experiments are used for validation of simple multilevel flow modeling models of a hydrocyclone unit for oil removal from produced water.

발효공정 자동제어를 위한 포도주 발효 중 포도당 농도 온라인 측정 (On-line Monitoring of a Glucose Concentration on a Fermentation Process of Wine for an Automatic Control of a Fermentation Process)

  • 송대빈
    • Journal of Biosystems Engineering
    • /
    • 제33권4호
    • /
    • pp.276-281
    • /
    • 2008
  • A flow injection analysis method (FIA), which analyzes sample conditions after injecting a sample and reagents into a continuous stream, are recognized as the most adequate analyzing method according to the increase of sampling frequency, the decrease of measuring time and the diversity of measuring targets. Specially, the FIA is considered to be used effectively for the control of a fermentation process to produce fermentation food and useful microbial production by activation of a fermentation industry for development of biological materials. In this study, a flow injection analysis sensor unit was developed for on-line monitoring of the fermentation process. The performance was verified by on-line measuring the concentration of glucose of the fermentation process of wine. The glucose concentrations of the samples were measured every 12 hours during the whole fermentation process and compared with those by a HPLC. The concentration relative errors of glucose on the fermentation process of wine showed below 30% within 72 hours and over 50% after the 72 hours. The sensor unit had potential to on-line monitoring of the fermentation process but some problems to overcome for an commercial application.

저속에서 피스톤 슈 내부 보조 링의 윤활 효과 분석 (Investigation of the Tribological Effects of the Auxiliary Inner Ring for Piston Shoes at Low Speeds)

  • 이성렬;김종혁;홍예선;김병곤;문진삼;문준혁
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권2호
    • /
    • pp.21-26
    • /
    • 2015
  • In order to design a swash plate type pump for electro-hydrostatic actuators the performance of the hydrostatic piston shoe bearings in the low speed range needs to be examined, since the pump operates frequently at low speeds, compensating for position control errors as a control element. As a common practice, piston shoes are equipped with inner rings as an auxiliary element to enhance their tribological performance. In this paper, the effects of the inner rings of the piston shoes on the frictional loss and leakage flow rate were investigated, where three piston shoe models, with different inner ring shapes and different inlet orifice sizes, were integrated. The test results showed that a large inner ring and small inlet orifice were advantageous for reducing both the frictional loss and leakage flow rate; this could also be confirmed by computational analyses.