• 제목/요약/키워드: Control criteria

검색결과 2,236건 처리시간 0.027초

Numerical study of dynamic buckling for plate and shell structures

  • Liu, Z.S.;Lee, H.P.;Lu, C.
    • Structural Engineering and Mechanics
    • /
    • 제20권2호
    • /
    • pp.241-257
    • /
    • 2005
  • A numerical approach combining the finite element method with two different stability criteria namely the Budiansky and the phase-plane buckling criteria is used to study the dynamic buckling phenomena of plate and shell structures subjected to sudden applied loading. In the finite element analysis an explicit time integration scheme is used and the two criteria are implemented in the Finite Element analysis. The dynamic responses of the plate and shell structures have been investigated for different values of the plate and shell imperfection factors. The results indicate that the dynamic buckling time, which is normally considered in predicting elasto-plastic buckling behavior, should be taken into consideration with the buckling criteria for elastic buckling analysis of plate and shell structures. By selecting proper control variables and incorporating them with two dynamic buckling criteria, the unique dynamic buckling load can be obtained and the problems of ambiguity and contradiction of dynamic buckling load of plate and shell structure can be resolved.

KS 인증 심사기준에서 과학적 기법의 적용 및 개선 방안 (Implementation and Improvement Strategies of Scientific Techniques in the Assessement Criteria of KS Certification)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.181-188
    • /
    • 2010
  • The research presents the implementation and improvement strategies of scientific methodologies and techniques in the audit criteria of KS certification. The paper discusses the establishment of management strategy and quality policy by the alignment of BSC or policy deployment, the effective handling methodologies of control plan based on SPC, and the traceability of calibration uncertainty and MSA, etc.

  • PDF

수치해석을 통한 지하공간의 제연설비 성능기준 검토 (A Study on the Performance Criteria of Smoke Control System for Underground Spaces Through Numerical Analysis)

  • 안찬솔;채한식;김흥열
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.356-362
    • /
    • 2008
  • 본 연구에서는 국내 화재 안전 기준 중 제연설비의 성능기준에 의해 지하 공간 건축물이 준공된 후 임의의 지점에서 화재가 발생했을 경우를 모델링하여 연기 확산 현상을 분석하고 제연 설비의 작동에 의한 재실자의 피난시간 연장과의 적정성을 검토하는 것이 목적이다. 본 연구의 선행연구에서는 가연물의 종류와 발열량을 추정하였으며 추정 값의 검토를 위하여 임의의 단일지하상가를 모델링하여 검증하였다. 그리고 지하상가의 제연설비가 작동될 경우와 작동되지 않을 경우에 대한 수치해석 결과를 비교하였으며 재실자의 피난시간을 확보하는 관점에서 화재 안전 기준에 대한 적정성을 검토하였다.

  • PDF

비행제어법칙 감항인증 기준 설정 및 입증 연구 (A Study for the Airworthiness Certification Criteria and Compliance Related to the Flight Control Law)

  • 고기옥;고준수;안영갑
    • 한국항공우주학회지
    • /
    • 제41권7호
    • /
    • pp.569-576
    • /
    • 2013
  • 군용항공기 산업의 비약적인 발전으로 정부의 군용항공기 감항인증은 점차적으로 중요한 역할을 차지하고 있다. 감항인증은 모든 항공기가 전 수명주기 동안 운용범위 내에서 비행안전에 적합하도록 항공기 개발에 필수적으로 요구되는 절차이다. 감항인증의 도입은 단일 수요자의 요구도에 부합되게 개발 해왔던 기존의 개발 사업특성에서 다수의 수요자의 공통의 요구도를 맞춘 개발 패러다임의 변화로 이끌어 가고 있다. 본 논문에서는 전투기급 항공기의 비행제어법칙의 감항인증 기준 설정에 대한 상세 연구와 감항인증 기술기준에 대한 입증 분석을 결과로 제시하였다.

수치해석을 이용한 이중보온관 발파진동 관리기준에 관한 연구 (A Study on Blasting Vibration Control Criteria for Pre-insulated Pipe through the Numerical Analysis)

  • 최봉혁;조진우;김진만;유한규
    • 대한토목학회논문집
    • /
    • 제33권4호
    • /
    • pp.1471-1478
    • /
    • 2013
  • 본 논문에서는 이중보온관의 발파진동 관리기준 제시를 위하여 이격거리와 매설심도를 변수로하여 수치해석을 수행하였다. 수치해석 적용 발파하중 모델은 현장시험 결과와의 비교를 통하여 검증하였다. 수치해석 결과, 이중보온관은 진동속도 4.0cm/sec 이상에서 발생 유효응력이 내관의 허용응력을 초과하거나 근접하는 것으로 나타났으며, 4.0cm/sec 이하에서 안정성이 확보되는 것으로 평가되었다. 따라서, 이중보온관의 진동관리기준은 4.0cm/sec를 초과하지 않도록 관리하여야 할 것으로 판단된다.

국내 고정익 무인항공기 감항인증 기술기준분석 (Airworthiness Standard Analysis about a Korea Fixed Wing Unmanned Aircraft)

  • 임준완;노진철;고준수
    • 한국군사과학기술학회지
    • /
    • 제19권5호
    • /
    • pp.654-661
    • /
    • 2016
  • An unmanned aircraft refers to an aircraft which carries no human pilot and is operated under remote control or in autonomous operational mode. An unmanned aircraft system consist of a one system which include UAV(s), UAV control station and data link, etc. As the UAVs can perform the dull, dangerous and difficult missions, various kinds of UAVs with different sizes and weights have been developed and operated for both civil and military areas. It is important to develop the airworthiness certification criteria of the UAVs to minimize the risks of fatal impacts on human life and environment and to achieve the equivalent level of safety to the manned aircraft. Analysis of the KAS Part 23 and STANAG 4671 can provide guidelines for the generation of the airworthiness certification criteria for the UAVs in civil application.

Numerical Bayesian updating of prior distributions for concrete strength properties considering conformity control

  • Caspeele, Robby;Taerwe, Luc
    • Advances in concrete construction
    • /
    • 제1권1호
    • /
    • pp.85-102
    • /
    • 2013
  • Prior concrete strength distributions can be updated by using direct information from test results as well as by taking into account indirect information due to conformity control. Due to the filtering effect of conformity control, the distribution of the material property in the accepted inspected lots will have lower fraction defectives in comparison to the distribution of the entire production (before or without inspection). A methodology is presented to quantify this influence in a Bayesian framework based on prior knowledge with respect to the hyperparameters of concrete strength distributions. An algorithm is presented in order to update prior distributions through numerical integration, taking into account the operating characteristic of the applied conformity criteria, calculated based on Monte Carlo simulations. Different examples are given to derive suitable hyperparameters for incoming strength distributions of concrete offered for conformity assessment, using updated available prior information, maximum-likelihood estimators or a bootstrap procedure. Furthermore, the updating procedure based on direct as well as indirect information obtained by conformity assessment is illustrated and used to quantify the filtering effect of conformity criteria on concrete strength distributions in case of a specific set of conformity criteria.

압연구동제어계(壓延驅動制御系)의 안정도(安定度) 판정법(判定法)에 관한 연구 (A study on the stability criterion of the control systems for the drive systems in rolling mill plants)

  • 정호성;백기남;강명조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.380-382
    • /
    • 1989
  • It is necessary for us to maintain good the quality of products in iron and steel making process, especially in the rolling mill plants. Thus, we need check the stability criteria of control systems. In the frequency domain, the whole system including controllers can be identified using FFT analyzer. But this method is not adequete where precise identification is demanded. Thus a way to complement the defects In the frequency domain analysis using FFT analyzer is introduced. And In the time domain, to establish the stability criteria on the control systems, the assumed parameters obtained using least square method are presented in this report.

  • PDF

Distributed Power Control and Removal Algorithms for Multimedia CDMA Wireless Networks

  • Wang, Jui-Teng
    • Journal of Communications and Networks
    • /
    • 제5권3호
    • /
    • pp.197-201
    • /
    • 2003
  • We study in this paper both distributed power control and removal algorithms for multimedia CDMA wireless networks. In our study, users can have different data rates as well as different quality of service (QoS) requirements. We derive a necessary and sufficient condition for the fully distributed power control (FDPC) algorithm to find a feasible power set. We also prove that, if the maximal power level is used at the start, then the distributed constrained power control (DCPC) algorithm is equivalent to the FDPC algorithm. For the connection removal algorithm, we prove that the non-reinitialized removal algorithm finds a feasible power set faster and employs smaller power levels than the reinitialized one does. Performances of some connection removal criteria are also studied. Our simulation results reveal that the smallest normalized CIR (SNC) and largest CIR requirement (LCR) criteria result in smaller outage probability than the smallest CIR (SC) criterion in a multimedia environment.

Research and Stability Analysis of Active-Disturbance-Rejection-Control-Based Microgrid Controllers

  • Xu, Xiaoning;Zhou, Xuesong;Ma, Youjie;Liu, Yiqi
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1611-1624
    • /
    • 2017
  • With the rapid development of microgrid technology, microgrid projects are no longer limited to laboratory demonstrations and pilot platforms. It shows greater value in practical applications. Hence, the smooth interaction between a microgrid and the main grid plays a critical role. In this paper, a control method based on active disturbance rejection control (ADRC) is proposed in order to realize seamless transitions between grid-connected and islanding operation modes and stable operation with variable loads. It is verified by simulations that the proposed ADRC-based method features better performance when compared to conventional proportional-integral-differential (PID) control. Meanwhile, the stability of the third-order extended state observer (ESO) in second-order ADRC is validated by using Lyapunov stability criteria.