• Title/Summary/Keyword: Control arm

Search Result 1,243, Processing Time 0.034 seconds

Comparison Study for Body Composition and Physical Function Fitness to the According of Exercise Type in Elderly Women

  • Lee, Jin-wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.4
    • /
    • pp.133-142
    • /
    • 2021
  • The purpose of this study was to examine the most suitable exercise for the elderly women by comparing the changes in body composition and physical function fitness after modern dance, aquarobic and combined exercise programs for the elderly women. The subjects of this study were 47 elderly women in J-do, chosen as MDG(n=13), AEG(n=11), CEG(n=11) and CG(n=12) for participated for 60 minutes/day and three times/wk for 12 weeks. The results of grip strength, chair stand, arm curl, 2 minute step, 244cm up and go was significantly than in the control group. Back scratch was decreased significantly after exercise only in the modern dance group and combined exercise group but there was no change in chair sit and reach. These results suggest that various exercises were found to play a positive role in maintaining and improving fitness for the elderly women. In addition, additional exercise programs are needed to improve flexibility and mobility of joints for the elderly. It is thought that it is important to voluntarily participate in a movement that suits your interests to make it sustainable.

Somatosensory evoked potentials are abnormal with plagiocephaly

  • Harma, Maiju;Lauronen, Leena;Leikola, Junnu;Hukki, Jyri;Saarikko, Anne
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.59-63
    • /
    • 2022
  • Background: Deformational plagiocephaly is usually managed conservatively, as it tends to improve over time and with the use of conservative measures. However, before the year 2017 we operated on patients with severe plagiocephaly and neurological symptoms at the Helsinki Cleft Palate and Craniofacial Center. Methods: Of the 20 infants with severe deformational plagiocephaly and neurological symptoms referred to us between 2014 and 2016, 10 underwent cranioplasty open reshaping of the posterior cranial vault. The parents of the last 10 patients were given information on the natural history of the condition and the patients were followed up with an outpatient protocol. The aim of this study was to gain information on the brain electrophysiology and recovery of patients after total cranial vault reconstruction by measuring the electroencephalogram (EEG) somatosensory evoked potentials (SEP; median nerve). Results: Of the 10 participants in the operation arm, six had abnormal SEP at least on the affected cerebral hemisphere and all SEPs were recorded as normal when controlled postoperatively. In the follow-up arm, eight out of 10 participants had abnormal SEP at the age of approximately 24 months, and all had normalized SEPs at control visits. Conclusion: Our data suggest that cranioplasty open reshaping of the posterior cranial vault did not affect abnormal SEP-EEG recordings. We have abandoned the operations in deformational plagiocephaly patients due to findings suggesting that expanding cranioplasty is not beneficial for brain function in this patient group.

The Effects of Instrument Pilates Exercise with EMS on Pain, Lymphedema and Range of Motion of Upper Extremity in Subjects after Mastectomy : Randomized Cross-over Design (국소적 전기근육자극을 결합한 기구 필라테스가 유방절제술 후 유방암 환자의 통증, 림프부종 및 팔 관절가동범위에 미치는 효과 : 무작위 교차실험 연구)

  • Kang, Chae-Young;Park, Hyun-Ju;Chon, Seung-Chul
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.113-120
    • /
    • 2022
  • Purpose : Lymphedema is a common complication in mastectomy patients and is usually characterized by pain, swelling, and limited range of motion (ROM) in the arm. Electromyostimulation (EMS) is widely used for the rehabilitation and recovery of subjects with various neuromusculoskeletal disorders after breast cancer. However, EMS has not yet been used in many Pilates exercises. This study was aimed at comparing the effects of instrument Pilates integrated with EMS on pain, lymphedema, and ROM of the upper extremity (UE) in breast cancer subjects after mastectomy. Methods : Nine female breast cancer subjects who had undergone mastectomy participated in the study. The subjects underwent instrument Pilates with EMS (experimental group) or instrument Pilates only (control group). Pain, lymphedema, and ROM of the UE were measured using the visual analog scale (VAS), the circumference length of the UE, and the ROM of the UE. The Wilcoxon signed-rank test was used to compare the pain, lymphedema, and ROM of the arm before and after the intervention, and the Mann-Whitney U test was used to compare the two groups. The statistical significance level was set to p < .05. Results : In the experimental group, there were significant differences in pain (p<.05) and UE circumference (p<.05) before and after intervention. However, there was no significant difference between the two groups in VAS (p>.05) or circumference length of the UE (p>.05). There was one significant difference between the groups in terms of internal rotation of the ROM of the UE (p<.05). Conclusion : These results show that instrument Pilates exercises combined with EMS may positively affect the internal rotation of the ROM of the UE in breast cancer patients after mastectomy, thus contributing to existing knowledge about instrument Pilates using EMS for the effective management of in breast cancer subjects after mastectomy.

Development of Knee Weight-bearing Radiography Assist Device (무릎 체중부하 촬영 보조장치 개발)

  • Yon-Lae Kim;Young-Woo Yoon
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.395-399
    • /
    • 2023
  • The knee arthritis patients are generally performed standing position radiography. However, patients with pain caused by degenerative diseases or injuries in the knee have difficulty maintaining a standing position. Therefore, this study aims to develop a knee joint standing weight bearing projection assist device to solve these problems when patients undergo knee radiography due to various diseases. The design of the knee joint weight-bearing radiography assist device is carried out with 3D design and drawing production to secure basic data, electric support and frame manufacture. A fixed device for maintaining the patient's knee standing weight-bearing projection, an electric digital height device, a digital protractor, and a safety device were designed. The arm support is made of PVC with a cushion to relieve the impact and make it easier to remove debris. The digital electric device can be moved up and down according to the patient's height, and a remote control is attached. The safety device is made to be adjustable in size by attaching metal hooks on both sides of the frame and to shield the scrotum. A digital protractor was attached to the side frame to set the desired knee angle. When a self-made assist device was used to perform a knee joint standing weight bearing projection, it helped maintain arm support and lower extremities position. In addition, the height could be adjusted using an assist device during standing projections, which helped the patient maintain the position.

Design of Driving Control Unit and Milking Robot Manipulator (착유로봇 매니퓰레이터와 구동제어장치 설계)

  • Shin, Kyoo Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.238-247
    • /
    • 2014
  • The milking robot system is very important to detect correctly the teats position in the moving condition of cow. Also, the robot manipulator must control tracking the teat cup to the detected teat position. The presented milking robot is designed using the one point laser sensor for teat position detection. The teats of cow are detected by the laser scanning unit and the manipulator has the function of 3 axes moving control unit. The presented teat detection method and the electrical driving manipulator have the advantages of a simple, low cost and very quiet. The designed manipulator is realized by the totally electrical motor and servo poison control algorithm with velocity PID compensation. The presented robot is realized using the teat detection unit, 4 teat cups, 3 axes robot arm, 6 servo motors and automatic milking control line. The designed robot is experimented in the cow farm and is satisfied with the designed performance specification for milking robot manipulator.

Effect of Neuromuscular Training on Postural Control and Jump Performance in Functional Ankle Instability Soccer Player (신경근 훈련이 기능적 발목 불안정성 축구선수의 자세조절과 점프 수행력에 미치는 영향)

  • Yang, Dae-Jung;Kang, Jeong-Il;Park, Seung-Kyu;Lee, Min-Ki;Jeong, Yong-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.295-300
    • /
    • 2014
  • The purpose of this study was to investigate the effects on jump performance and balance in soccer player with functional ankle instability of difference of neuromuscular training. In 33 male college soccer player with functional ankle instability subjects of this study randomization, combined training group (group I, n=11), balance training group (group II, n=11) and control group (group III, n=11) that included in the plyometric training and balance training was classified group. The intervention was conducted three times a week for 8 weeks. Before and after intervention, measured in surface area ellipse and countermovement jump and countermovement jump with arm swing. Showed a significant improvement in postural control and jump performance from the combined training group and balance training group compared to the control group. Showed a significant improvement in countermovement jump from the combined training group compared to the balance training group. Combined training and balance training showed the increased jump performance and postural control in soccer player with functional ankle instability.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Radiation Dose-escalation Trial for Glioblastomas with 3D-conformal Radiotherapy (3차원 입체조형치료에 의한 아교모세포종의 방사선 선량증가 연구)

  • Cho, Jae-Ho;Lee, Chang-Geol;Kim, Kyoung-Ju;Bak, Jin-Ho;Lee, Se-Byeoung;Cho, Sam-Ju;Shim, Su-Jung;Yoon, Dok-Hyun;Chang, Jong-Hee;Kim, Tae-Gon;Kim, Dong-Suk;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.237-246
    • /
    • 2004
  • Purpose: To investigate the effects of radiation dose-escalation on the treatment outcome, complications and the other prognostic variables for glioblastoma patients treated with 3D-conformal radiotherapy (3D-CRT). Materials and Methods: Between Jan 1997 and July 2002, a total of 75 patients with histologically proven diagnosis of glioblastoma were analyzed. The patients who had a Karnofsky Performance Score (KPS) of 60 or higher, and received at least 50 Gy of radiation to the tumor bed were eligible. All the patients were divided into two arms; Arm 1, the high-dose group was enrolled prospectively, and Arm 2, the low-dose group served as a retrospective control. Arm 1 patients received $63\~70$ Gy (Median 66 Gy, fraction size $1.8\~2$ Gy) with 3D-conformal radiotherapy, and Arm 2 received 59.4 Gy or less (Median 59.4 Gy, fraction size 1.8 Gy) with 2D-conventional radiotherapy. The Gross Tumor Volume (GTV) was defined by the surgical margin and the residual gross tumor on a contrast enhanced MRI. Surrounding edema was not included in the Clinical Target Volume (CTV) in Arm 1, so as to reduce the risk of late radiation associated complications; whereas as in Arm 2 it was included. The overall survival and progression free survival times were calculated from the date of surgery using the Kaplan-Meier method. The time to progression was measured with serial neurologic examinations and MRI or CT scans after RT completion. Acute and late toxicities were evaluated using the Radiation Therapy Oncology Group neurotoxicity scores. Results: During the relatively short follow up period of 14 months, the median overall survival and progression free survival times were $15{\pm}1.65$ and $11{\pm}0.95$ months, respectively. The was a significantly longer survival time for the Arm 1 patients compared to those in Arm 2 (p=0.028). For Arm 1 patients, the median survival and progression free survival times were $21{\pm}5.03$ and $12{\pm}1.59$ months, respectively, while for Arm 2 patients they were $14{\pm}0.94$ and $10{\pm}1.63$ months, respectively. Especially in terms of the 2-year survival rate, the high-dose group showed a much better survival time than the low-dose group; $44.7\%$ versus $19.2\%$. Upon univariate analyses, age, performance status, location of tumor, extent of surgery, tumor volume and radiation dose group were significant factors for survival. Multivariate analyses confirmed that the impact of radiation dose on survival was independent of age, performance status, extent of surgery and target volume. During the follow-up period, complications related directly with radiation, such as radionecrosis, has not been identified. Conclusion: Using 3D-conformal radiotherapy, which is able to reduce the radiation dose to normal tissues compared to 2D-conventional treatment, up to 70 Gy of radiation could be delivered to the GTV without significant toxicity. As an approach to intensify local treatment, the radiation dose escalation through 3D-CRT can be expected to increase the overall and progression free survival times for patients with glioblastomas.

Effects of Cervi cornu parvum and Soahbohyul - tang combined with Cervi cornu parvum on LPS-induced fever pattern differences in rabbits, and learning and memory in rats (발열 상태에서 투여된 녹용(鹿茸)과 소아보혈탕(小兒補血湯) 가(加) 녹용(鹿茸)이 발열 양상의 변화 및 학습과 기억에 미치는 영향)

  • Choi Hyuk-Yong;Lee Jin-Yong;Kim Deok-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.9-38
    • /
    • 2000
  • It has been widely said in Korea that early administrations of Cervi cornu parvum (deer antler) to febrile infants affect brain functions. Traditional Oriental Medicine states that the head is easily affected by fever and only an excess of heat causes headaches. Traditional Oriental Medicine also states that Cervi cornu parvum cannot be used in febrile conditions. With the aim of investigating different febrile response to LPS, experiments using intravenous injection of LPS have been carried out on Cervi comu parvum(CCP) and Soahbohyul - tang combined with Cervi comu parvum(SB-CCP) administered rabbits. Experiments were also conducted to evaluate the effects of early administration of CCP on learning and memory in 3 week old rats with LPS fever. These were evaluated by using the Morris water maze and the radial arm maze. Changes in body weight were also observed during this period. The results of these experiments are as follows. 1. In the experiments with febrile rabbits, the CCP and SB-CCP administered group showed statistically significant reductions of fever (p<0.05). 2. In the experiments with febrile rabbits, CCP and SB-CCP administered rabbits resulted in the tendency of lower body temperatures and shorter fever periods than the control group. 3. There were no differences of mean body weight and fever patterns among the 4 groups in the experiments on young rats with LPS fever. 4. There was no statistical difference of mean response latencies among the rats in Group I (DDW administered), GroupIII (CCP administered), and groupIV (SB-CCP administered) in the Morris water maze. However, Group Ⅱ (the scopolamine administered group) showed delayed latencies on the second day of the first session (p<0.05), and the second and third day of the second session (p< 0.05). 5. There were no statistical differences of mean response latencies among the rats in Group I, III and Ⅳ in the radial arm maze, but Group Ⅱ showed delayed latencies on the first and third day of the first session (p<0.05). 6. There was no influence from the administration of CCP and SB-CCP on the general behavior of the rats in Irwin´s test. These results suggest that Cervi cornu parvum and Soahbohyul - tang combined with Cervi comu parvum have anti-pyretic actions on LPS fever. The results also suggest that these drugs have no influence on learning and memory in young rats with LPS fever in the Morris water maze and the radial arm maze.

  • PDF

Dynamic Power Management Framework for Mobile Multi-core System (모바일 멀티코어 시스템을 위한 동적 전력관리 프레임워크)

  • Ahn, Young-Ho;Chung, Ki-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.52-60
    • /
    • 2010
  • In this paper, we propose a dynamic power management framework for multi-core systems. We reduced the power consumption of multi-core processors such as Intel Centrino Duo and ARM11 MPCore, which have been used at the consumer electronics and personal computer market. Each processor uses a different technique to save its power usage, but there is no embedded multi-core processor which has a precise power control mechanism such as dynamic voltage scaling technique. The proposed dynamic power management framework is suitable for smart phones which have an operating system to provide multi-processing capability. Basically, our framework follows an intuitive idea that reducing the power consumption of idle cores is the most effective way to save the overall power consumption of a multi-core processor. We could minimize the energy consumption used by idle cores with application-targeted policies that reflect the characteristics of active workloads. We defined some properties of an application to analyze the performance requirement in real time and automated the management process to verify the result quickly. We tested the proposed framework with popular processors such as Intel Centrino Duo and ARM11 MPCore, and were able to find that our framework dynamically reduced the power consumption of multi-core processors and satisfied the performance requirement of each program.