• Title/Summary/Keyword: Control arm

Search Result 1,243, Processing Time 0.028 seconds

Considerations on an Oriental Medical Doctor like Indentation System (한의사 맥진 가압력 재현에 대한 고찰)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, the indentation pressure is one of the most important factors as well as the change of pulse shape and the distribution of pressure via time. But, on the oriental medical doctor's indentation pressure control, the understandings of the neurophysiological meanings and mechanisms have been lacked. So, in this paper, we considered on these issues and then proposed a proper system which can imitate the OMD's indentation pressure control mechanisms. As a result, both tactile information and kinesthetic information were found to be essential to the indentation pressure control so that a system, which can measure both the physical indent pressure and the displacement of an indentation arm, has been proposed. With this proposed system, while the indentation was being controlled through the moving step number of the step motor, the physical indentation pres sure and displacement of the indentation arm were measured. From these measured data, the relationships between the moving step number and both physical indentation pressure and displacement were revealed to have linear characteristics in early phase and to have nonlinear characteristics in latter phase. Additionally, three types of graph were generated whose X axis means the moving step number, the physical indentation pressure and the displacement respectively and Y axis means the pulse pressure. By comparing these graphs, we come to conclude that different concepts on indentation pressure control cause different diagnostic results on floating/sinking degrees for the same subject. Consequently, an indentation system for the pulse diagnosis should be able to provide both the tactile information and kinesthetic information, that is, the physical indentation pressure and the displacement of the indentation arm. In future, the proposed system should be optimized to the pulse diagnosis environment and how to combine the both information for more reliable diagnosis should be studied.

  • PDF

Effect of Screening on Variation in Cervical Cancer Survival by Socioeconomic Determinants - a Study from Rural South India

  • Thulaseedharan, Jissa Vinoda;Malila, Nea;Swaminathan, Rajaraman;Esmy, Pulikottil Okuru;Cherian, Mary;Hakama, Matti;Muwonge, Richard;Sankaranarayanan, Rengaswamy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5237-5242
    • /
    • 2015
  • Background: Socioeconomic factors are associated with screening in terms of reducing the risk of cervical cancer. This study aimed to clearly establish the effect of screening on variation in socio-economic factor-specific survival estimates. Materials and Methods: Survival estimates were calculated using the life table method for 165 women from the routine care control arm and 67 from the visual inspection with acetic acid screening arm diagnosed with cervical cancer during 2000-2006 in rural south India. Kaplan-Meier survival curves were plotted to compare the variation in survival by socioeconomic factors. Results: Whereas there was a significant variation in survival estimates of the different categories of age at diagnosis among the screen-detected cancers with women aged<50 years having an improved survival, no significant variation was noted among women diagnosed with cervical cancer from the control arm. Compared to the variation among the cancer cases detected in the unscreened control group, screening widened the variation in survival estimates by age and type of house, and reduced the variation by education. The direction of the magnitude of the survival estimates was reversed within the different categories of occupation, marital status and household income in the screen-detected cancer cases compared to control group cancer cases. Also, women diagnosed with stage 1 disease had a very good survival. Conclusions: Screening changed the pattern of survival by socio-economic factors. We found improved survival rates in screened women aged <50 years, with no formal education, manual workers and married women.

The Implementation of Embedded Web Server System for a Remote Control and Measurement (원격 제어 및 계측을 위한 임베디드 웹 서버 시스템 구현)

  • Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.839-845
    • /
    • 2012
  • This paper deals with the design and development of the remote control and measurement systems by Embedded Web Server. The remote control and measurement systems are implemented by Cortex M-3 ARM micro-controller. The user application software for the control and measurement system user, and the firmware software of device drivers for peripherals such as a digital input/output device, AD/DAC(Analog to Digital/Digital to Analog Converter), LCD, and temperature/humidity sensor are developed in Eclipse environment using Codesourcery C, Java script, and HTML. The experimental result of the proposed control and measurement systems implemented in this paper is evaluated via real-time experiments, which works well as designed.

An algorithm for real-time control of a 3D avatar by symmetry-formed motions (대칭형 자유동작에 의한 3D 아바타 실시간 제어 알고리즘)

  • Chang, Hee-Dong
    • Journal of Korea Game Society
    • /
    • v.3 no.2
    • /
    • pp.24-29
    • /
    • 2003
  • The market of digital avatar with internet and digital technology is increasing rapidly. The users want to express any free-formed motion of their avatars in the cyber space. The user s motion capturing method as the avatar's motion can express any free-formed motion of the avatar in real-time but the methods are expensive and inconvenient. In this paper, we proposed a new method of expressing any free-formed motion of the avatar in real-time. The proposed method is an algorithm for real-time control of a 3D avatar in symmetry-formed free motion. Specially, the algorithm aims at the motion control of a 3D avatar for online dancing games. The proposed algorithm uses the skeleton character model and controls any one of two hands of the character model by a joystick with two sticks. In the symmetry-formed motion, the position and orientation of one hand can determine the position and orientation of the other hand. And the position and orientation of a hand as an end-effector can determine the pose of the arm by Inverse Kinematics. So the algorithm can control the symmetry-formed free motions of two arms by one joystick with two sticks. In the dance game, the algorithm controls the arm motion by the joystick and the other motion by the motion captured DB.

  • PDF

A development of a general purposed control system of robot end-effector for inspection and maintenance of steam generator heat pipe (증기발생기전열관의 검사정비로봇용 엔드이펙터의 범용 제어시스템 개발)

  • Park, Ki-Tae;Kim, Seon-Jin;Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • The general purposed control system for driving a motion of many different typed robot end-effector, which consists of a controller based on ARM Cotex M3-11017 MCU and an application software for generating a motion of end-effector, was developed. Experimental results show that a positioning error is nearly negligible and a repeatability error is 0.04%. Accordingly the developed control system can be applied practically to actuate a robot end-effector for inspection and maintenance of steam generator heat pipe in nuclear power plant.

Adaptive control of flexible joint robot manipulators (유연성 관절 로봇 매니퓰레이터 적응 제어)

  • 신진호;이주장
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.260-265
    • /
    • 1992
  • This paper presents an adaptive control scheme for flexible joint robot manipulators. This control scheme is based on the Lyapunov direct method with the arm energy-based Lyapunov function. The proposed adaptive control scheme uses only the position and velocity feedback of link and motor shaft. The adaptive control system of flexible joint robots is asymptotically stable regardless of the joint flexibility value. Therefore, the assumption of weak joint ealsticity is not needed. Also, joint flexibility value is unknown. Simulation results are presented to show the feasibility of the proposed adaptive control scheme.

  • PDF

Design of an Integrated Interface Circuit and Device Driver Generation System (인터페이스 회로와 디바이스 드라이버 통합 자동생성 시스템 설계)

  • Hwang, Sun-Young;Kim, Hyoun-Chul;Lee, Ser-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6B
    • /
    • pp.325-333
    • /
    • 2007
  • An OS requires the device driver to control hardware IPs at application level. Development of a device driver requires specific acknowledge for target hardware and OS. In this paper, we present a system which generates a device driver together with an interface circuit. In the proposed system, an efficient device driver is generated by selecting a basic device driver skeleton, a function module code, and a header file table from the pre-constructed library and an interface circuit is constructed such that the generated device driver operates correctly. The proposed system is evaluated by generating a TFT-LCD device driver on the ARM922T core with 3.5 inch Samsung TFT-LCD in ARM-Linux environment. Experiment result shows that the writing time on the LCD is decreased by 1.12% and the compiled code size is increased by 0.17% compared to the manually generated one. The automatically generated device driver has no performance degradation in the latency of hardware control at the application program level. The system development time can be reduced using the proposed device driver generation system.

3-D vision sensor for arc welding industrial robot system with coordinated motion

  • Shigehiru, Yoshimitsu;Kasagami, Fumio;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.382-387
    • /
    • 1992
  • In order to obtain desired arc welding performance, we already developed an arc welding robot system that enabled coordinated motions of dual arm robots. In this system one robot arm holds a welding target as a positioning device, and the other robot moves the welding torch. Concerning to such a dual arm robot system, the positioning accuracy of robots is one important problem, since nowadays conventional industrial robots unfortunately don't have enough absolute accuracy in position. In order to cope with this problem, our robot system employed teaching playback method, where absolute error are compensated by the operator's visual feedback. Due to this system, an ideal arc welding considering the posture of the welding target and the directions of the gravity has become possible. Another problem still remains, while we developed an original teaching method of the dual arm robots with coordinated motions. The problem is that manual teaching tasks are still tedious since they need fine movements with intensive attentions. Therefore, we developed a 3-dimensional vision guided robot control method for our welding robot system with coordinated motions. In this paper we show our 3-dimensional vision sensor to guide our arc welding robot system with coordinated motions. A sensing device is compactly designed and is mounted on the tip of the arc welding robot. The sensor detects the 3-dimensional shape of groove on the target work which needs to be weld. And the welding robot is controlled to trace the grooves with accuracy. The principle of the 3-dimensional measurement is depend on the slit-ray projection method. In order to realize a slit-ray projection method, two laser slit-ray projectors and one CCD TV camera are compactly mounted. Tactful image processing enabled 3-dimensional data processing without suffering from disturbance lights. The 3-dimensional information of the target groove is combined with the rough teaching data they are given by the operator in advance. Therefore, the teaching tasks are simplified

  • PDF

Meta-analysis of Six Randomized Control Trials of Chemotherapy Plus Anti-HER Monoclonal Antibody for Advanced Gastric and Gastroesophageal Cancer

  • Luo, Huai-Qing;Han, Li;Jiang, Yan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5343-5348
    • /
    • 2014
  • Background: A meta-analysis was performed to examine the benefit/risk ratio for the addition of anti- HER MoAbs to chemotherapy in patients with advanced gastric and gastroesophageal cancer from six randomized phase II/III trials. Materials and Methods: We searched relative trials from Pubmed, EMBASE, Cochrane library databases, China National Knowledge Infrastructure databases, Google Scholar and the NIH ClinicalTrials. Primary outcomes were overall response rate (ORR), progression-free survival (PFS), overall survival (OS). Secondary outcomes were toxicities. All analyses were performed using STATA 12.0. Results: This meta-analysis included six randomized controlled trials (RCTs) with 2, 297 patients and we demonstrated that the anti-HER MoAbs arm did have a positive effect on ORR in the anti-HER MoAbs arm (OR 1.28, 95% CI 1.00-1.64, p=0.01). There was an increasing benefit regarding OS (HR 0.74, 95% CI 0.60-0.88, p<0.05) and PFS (HR 0.72, 95% CI 0.60-0.84, p<0.05) in the anti-HER2 subgroup, but a reduction of OS (HR 1.11, 95% CI 0.87-1.36, p<0.05) and PFS (HR 1.13, 95% CI 0.98 -1.28, P<0.05) in anti-EGFR subgroup. Some grade 3-4 toxicity had a significantly higher incidence in the anti-HER MoAbs arm. There was no significant publication bias for all endpoints. Conclusions: The addition of trstuzumab MoAb to chemotherapy for gastric and gastroesophageal cancer significantly improved outcome of OS and PFS endpoints, while other MoAbs led to no improvement in results. Some adverse events were increased in anti-HER MoAbs arm compared with the control.

의료용재료의 최근 개발현황

  • 김영하
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 1989
  • The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan`s method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements.

  • PDF