• Title/Summary/Keyword: Control Zone

Search Result 1,502, Processing Time 0.028 seconds

Zone-based Power Control Scheme for DS-CDMA Reverse Link Systems (DS-CDMA 역방향 링크에서의 Zone-based 전력제어 방식)

  • 윤승윤;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8A
    • /
    • pp.868-878
    • /
    • 2004
  • In this paper, we analyse feasibility of Zone-based Power Control (ZPC) scheme introduced for CDMA forward link(1) in the reverse link. To operate ZPC scheme in the CDMA systems the maximum power level that can be allocated to each traffic channel should be determined. Because all the service channels share the whole power resource in the forward lint a specific mechanism that determines Maximum power resource to each traffic channel is required to operate ZPC scheme in the forward link. However, ZPC scheme can be easily adopted to the reverse link, because of the fact that the whole power resource of service terminal is only confined to its traffic channel. In other words, we need not to determine the maximum power resource to be allocated in the reverse traffic channel. Simulation results show that ZPC scheme adopted to the reverse link yields a significant performance improvement compared with the conventional TPC(IS-95 TPC) scheme in terms of the power consumption and the traffic capacity of Portables, especially with the increasing number of high-rate data traffics. With the proposed scheme, not only be extended the service coverage of high-rate data traffic to the entire cell service coverage, but also the QoS of low-rate traffic can keep going through the service time, especially, in the situation that the incoming interference is much larger.

Evaluation of Corrosion Characteristics on Welding Zone of Leakage SeawaterPipe Welded by Underwater Welding Electrode (수중 용접봉으로 용접한 누수배관 용접부위의 부식 특성 평가)

  • Moon, Kyung-Man;Lee, Sung-Yul;Kim, Yun-Hae;Lee, Myung-Hyoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1240-1247
    • /
    • 2008
  • Leakage trouble on the sea water pipeline in engine room is often resulted from a localized corrosion due to severe corrosive environment caused by both high speed and high pressure of sea water flowing through the inner pipe. In addition, when the ship is in stand-by or emergency condition, underwater welding to control the leakage of sea water from a hole of its pipe is very important in an industrial safety point of view. In this study possibility of underwater welding to control leakage of sea water and corrosion property of its welding zone were investigated with the electrochemical methods by parameters of welding methods and welding electrodes when underwater welding is achieved with a such case that sea water is being leaked out with a height at 50mm from a hole of $2.5mm{\emptyset}$ of test pipe. Corrosion resistance of weld metal zone is better than the base metal and its hardness is higher than that of the base metal. However corrosion potential of weld metal zone showed a negative value than that of the base metal, therefore weld metal zone is preferentially corroded rather than the base metal by performance of galvanic cell due to difference of corrosion potential between weld metal zone and base metal. Eventually it is suggested that leakage of sea water is successfully controlled by underwater welding,

Effect of Root Zone Temperature during the Night on the Growth and yield of Perlite Cultured Tomato in Winter (겨울철 토마토 2단말식 펄라이트경에서 야간 근권 온도가 토마토의 생육 및 수량에 미치는 영향)

  • 이한철;강경희;권기범;최영하
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.30-35
    • /
    • 2001
  • This experiment was undertaken to investigate the effect of root zone temperature during the night on absorption of mineral nutrients, growth, and fruit yield of the truss-limited hydroponic tomatoes in winter. The root zone temperature was either controlled to 10, 15, 20, $25^{\circ}C$, or left uncontrolled at ambient temperatures. Temperature of the covered beds rose as root zone temperature was raised, but it in all treatments was less than 3$^{\circ}C$ higher than that in the control. Raising root zone temperature, except $25^{\circ}C$, showed positive effect on plant height, leaf length, stem diameter, and plant fresh and dry weight, but not on T/R ratio which was the greatest in the control. Root activity in all treatments except $25^{\circ}C$ increased as compared to the control. Mean fruit weight, fruit count per plant, and fruit yield were the greatest in 2$0^{\circ}C$ treatment. Root zone temperature did not significantly affect the contents of total nitrate and magnesium in leaves, stems and roots. Concentrations of phosphate and calcium increased in leaves and stems, but decreased in roots as root zone temperature increased. Overall, 2$0^{\circ}C$ treatment gave the greatest growth and energy efficiency.

  • PDF

THE EXPERIMENTAL STUDY ON THE CHANGES OF CONDYLAR HEAD FOLLOWING UNILATERAL DISCECTOMY IN RABBIT (가토 편측 악관절원판 제거 후 하악 과두 변화에 관한 실험적 연구)

  • Park, Kwang-Jin;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.758-770
    • /
    • 1996
  • Discectomy is the oldest and most commonly performed operation for the painful temporomandibular joint with internal derangement. It is the one operation for which there are longest follow-up study, with Eriksson, Silver, and Tolvanen et al reporting good results in patients about 30 years after discectomy. About 80% to 90% of patients clinically experience relief from pain and dysfunction after discectomy, and interestingly, the results may improve with time. However such as Myrhaug found headache and Poswillo supposed pain and limitation of movement as postoperative complications, even though this operation had the longest follow-up term, several aspects of discectomy remain unclear. The controversies to discectomy for TMJ with pain and dysfunction have laid emphasis only upon clinical results, and then the histomorphological study was planned to evaluate the morphologic change of TMJ after discectomy. To clarify the nature of the change through an observation on the morphologic changes of articular cartilage and subchondral bone of the condyle resulting from experimental unilateral discectomy in rabbit, the author excised the left articular discs of 12 male rabbits(control 4 rabbits), weighing about 3kg, and at 1, 3, 6, 9 weeks following surgery, harvested both(left surgical site and right nonsurgical sits) TMJ. The specimens were examined with light microscope after H-E and MT stain and the obtained results were as follows. 1. Histopathological features showed thickening of articular zone and active proliferation of fibrocartilaginous zone associated with slight proliferative zone in surgical site than control group. Also replacement of chondrocytes in calcified cartilaginous zone into bone cells was observed. 2. There were thinning of thickness of each zone of articular cartilage except calcified cartilagnous zone was observed in nonsurgical site. 3. In MT stain of condylar trabeculae, there was increased calcification in nonsurgical site than control and surgical site and the degree of calcification was similar in surgical site and control group. 4. In both site of experimental group no features of degenerative changes were observed. From the above results, it is presumed that the morphologic changes of surgical site discectomy are compensatory remodeling process characterized by an hyperplastic reaction of the articular zone and fibrocartilaginous zone filling the void created by removing the disc, and the bone changes are secondary to changes in the cartilage. Increased degree of calcification seen in condylar trabeculae of nonsurgical site results from the excessive use of condyle of that site.

  • PDF

New approach on prediction of fault zone ahead of tunnel face by using $x-R_s$ control chart for RMR parameters (RMR 변수의 $x-R_s$ 관리도 분석을 통한 굴착면 전방 단층대 예측 기법)

  • Yim, Sung-Bin;Kim, Kwang-Yeom;Kim, Chang-Yong;Seo, Yong-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.6
    • /
    • pp.463-473
    • /
    • 2010
  • A new approach for prediction of a fault zone ahead of tunnel face by using statistical control charts is suggested and applied to the construction site. $x-R_s$ control charts of RMR parameters were investigated as approaching and passing through fault zone. The abnormal signal from the control charts was observed and analyzed based on statistical criteria. Fault zones in the application area were predicted in advance using this method and it was verified by comparing with observation data like horizontal boring and face mapping.

Personal Monitor & TV Audio System by Using Loudspeaker Array (스피커 배열을 이용한 개인용 모니터와 TV의 오디오 시스템)

  • Lee, Chan-Hui;Chang, Ji-Ho;Park, Jin-Young;Kim, Yang-Hann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.701-710
    • /
    • 2008
  • Including a TV set and a monitor, personal audio system is raising a great interest. In this study, we applied a method to make a good bright zone around the user and dark zone to other region by maximizing the ratio of sound energy between the bright and dark zone. It has been well known as acoustic contrast control. We have attempted to use a line loudspeaker array system to localize the sound in our listening zone. It depends on the size of the zone and array parameters, for example, array size, loudspeaker unit spacing, wave length of sound. We have considered these parameters as spatial variables and studied the effects. And we have found that each spatial variable has its own characteristic and shows very different effect. Genetic algorithms are introduced to find out the optimum value of spatial variables. As a result, we can improve the result of the acoustic contrast control by optimum value of spatial variables.

Quasi-LQG/$H_{infty}$/LTR Control for a Nonlinear Servo System with Coulomb Friction and Dead-zone

  • Han, Seong-Ik
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.2
    • /
    • pp.24-34
    • /
    • 2000
  • In this paper we propose a controller design method, called Quasi-LQG/$H_{\infty}$/LTR for nonlinear servo systems with hard nonlinearities such as Coulomb friction, dead-zone. Introducing the RIDF method to model Coulomb friction and dead-zone, the statistically linearized system is built. Then, we consider $H_{\infty}$ performance constraint for the optimization of statistically linearized systems, by replacing a covariance Lyapunov equation into a modified Riccati equation of which solution leads to an upper bound of the LQG performance. As a result, the nonlinear correction term is included in coupled Riccati equation, which is generally very difficult to thave a numerical solution. To solve this problem, we use the modified loop shaping technique and show some analytic proofs on LTR condition. Finally, the Quasi-LQG/$H_{\infty}$/LTR controller for a nonlinear system is synthesized by inverse random input describing function techniques (ITIDF). It is shown that the proposed design method has a better performance robustness to the hard nonlinearity than LQG/$H_{\infty}$/LTR method via simulations and experiments for the timing-belt driving servo system that contains the Coulomb friction and dead-zone.

  • PDF

Development and Evaluation of the Upper & Lower side Ondol System in Apartment Houses (공동주택의 윗목/아랫목 온돌 제어시스템 개발 및 평가)

  • Cho, D.W.;Yu, K.H.;Yu, J.Y.;Jung, H.K.;Kim, Y.H.;Kim, S.H.;U., M.;Yang, I.H.
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.627-636
    • /
    • 2008
  • The purpose of this study is to develop the new korean district heating system for apartment houses. The upper & lower side ondol system with multi sensing control system was developed as a new korean district heating system and evaluated in 2 mock-up laboratories last winter. As a result of field measurement, when the load differences between perimeter zone and central zone are increased, the ondol system divided in the upper and lower side can be evaluated as the new ondol system with a capability for suppling proper heating energy for each zone. The user can have the freedom for changing an upper zone and a lower zone and controlling each temperature according to their needs.

  • PDF

Zone-based Power Control Mechanism of CDMA Forward Link for High-speed Wireless Data Services (고속 무선 데이터 서비스를 위한 CDMA 순방향 링크에서의 Zone-based 전력제어 방식)

  • 윤승윤;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7B
    • /
    • pp.673-685
    • /
    • 2002
  • In this paper, we analyze the pros and cons of the fast power control to the forward link in the environments where mixed traffics of voice and data produce the transmitted/received power difference. We propose the Zone-based power control scheme that can improve the performance of the fast power control scheme in the viewpoint of the resource allocation. The proposed scheme is a mechanism that controls both the power and rate of non-realtime data traffics according to location distribution of the mobile stations. The scheme is based on the conventional fast power control scheme in the CDMA systems, and it adaptively controls the transmission rate of each data traffic. Zone-based rate control of data call brings about somewhat power margin to the call. As a result, the proposed scheme saves the power consumption of portables and reduces the amount of interference. With the proposed scheme, not only be extended the service coverage of high-rate traffic to the entire cell service coverage, but also the QoS of low-rate traffic can keep going through the service time, especially, in the situation that the amount of incoming interference is much larger. The experimental results show that the proposed scheme yields a improved performance compared with the conventional scheme in terms of the power consumption and traffic throughput of portables, especially, with the increasing number of high-rate data traffics.

Quiet Zone Generation by Absorption Materials (흡음재 배치를 이용한 정숙 공간 형성 방법)

  • Park, Joo-Bae;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.403-408
    • /
    • 2000
  • An acoustic field in a 3 dimensional enclosure is caused from interference between sound sources and the complex reflections from wall. Therefore, changing an acoustic property of wall such as admittance means generating another acoustic field. The purpose of this paper is utilizing the characteristic to make a quiet zone. First, this paper shows that the control material is essentially on the same road as active noise control(ANC). That is, we can consider the control material as the control source of ANC. However we cannot control the reflection strength of it. Second, through a numerical simulation, this paper shows that the position of the control material is an important variable of the control.

  • PDF