• Title/Summary/Keyword: Control Zone

Search Result 1,500, Processing Time 0.032 seconds

투사영상 불변량을 이용한 장애물 검지 및 자기 위치 인식 (Obstacle Detection and Self-Localization without Camera Calibration using Projective Invariants)

  • 노경식;이왕헌;이준웅;권인소
    • 제어로봇시스템학회논문지
    • /
    • 제5권2호
    • /
    • pp.228-236
    • /
    • 1999
  • In this paper, we propose visual-based self-localization and obstacle detection algorithms for indoor mobile robots. The algorithms do not require calibration, and can be worked with only single image by using the projective invariant relationship between natural landmarks. We predefine a risk zone without obstacles for a robot, and update the image of the risk zone, which will be used to detect obstacles inside the zone by comparing the averaging image with the current image of a new risk zone. The positions of the robot and the obstacles are determined by relative positioning. The method does not require the prior information for positioning robot. The robustness and feasibility of our algorithms have been demonstrated through experiments in hallway environments.

  • PDF

지지부 위치와 벽면 두께변화에 따른 구형 인공위성 추진제 탱크의 강도해석

  • 한근조;전언찬;김중완;안성찬;심재준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.528-532
    • /
    • 1997
  • The structure of satellite was of six parts of control system, power system, thermal control system, remote measurement command system, propellant system and thrust system. In these parts, propellant system consists of propellant tank and thrust device. What we want to perform is optimum design to minimaize the weight of propellant tank. In order to design optimal propellant tank, several parameters should be adopted form the tank geometry like the relative location of the lug and variation of the wall thickness. So the analysis was executed by finite element analysis for finding optimal design parameters. The structure was devided into 3 parts, the initial thickness zone, the transitional zone, and the weak zone,whose effects on the pressure vessel strength was investigated. Finally the optimal lug location and the three zone thickness were obtained and the weight was compared with the uniform thickness vessel.

  • PDF

Zone-Control기능을 지원하는 지능형 센서네트워크 미들웨어 (An Intelligent Sensor Network Middleware supporting Zone-control function)

  • 이지현;임경식
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2004년도 가을 학술발표논문집 Vol.31 No.2 (3)
    • /
    • pp.628-630
    • /
    • 2004
  • 센서네트워크 미들웨어는 에너지 사용에 제약을 가지는 센서네트워크의 요구사항과 다양한 서비스 제공을 위한 응용서비스의 확장성을 고려하여 센서네트워크와 응용서비스가 상호 분리되어 각각의 기능을 수행하도록 설계되어야 한다. 따라서 본 논문에서는 Zigbee기반의 센서네트워크를 구성하여 센서들의 에너지 사용을 최소화함으로써 센서네트워크의 효율성을 증대시키고. 응용 서비스의 독립된 수행과 Zone을 통한 응용서비스의 지역적인 제공이 가능한 지능형 센서네트워크 미들웨어를 제안한다. 제안된 센서네트워크 미들웨어에서는 특정 센서로부터 전달된 내용을 Context-aware과정을 통하여 다른 기능을 가진 센서들의 연속적인 센싱을 유도하고, Zone Manager를 통하여 효과적인 서비스의 지역적인 제공 기능을 수행한다.

  • PDF

곤충 행동 양식 기반의 애드 혹 네트워크를 위한 존 반경 결정 알고리즘 (Insect-Inspired Algorithm for Zone Radius Determination of Ad-hoc Networks)

  • 이혜민;김동성
    • 제어로봇시스템학회논문지
    • /
    • 제20권10호
    • /
    • pp.1079-1083
    • /
    • 2014
  • In this paper, a new zone radius determination algorithm is proposed for a nature-inspired routing protocol that emulates the foraging behavior of bees based on their ability to find an optimal route from nectar sites. Instead of changing the radius of nodes one-hop by one-hop, the proposed algorithm alters the radius of nodes as gaps of another radius and adapt quickly to network conditions. The simulation results show that the proposed algorithm has higher efficiency compared with existing studies in an aspect of computational complexity and end-to-end delay.

용수로의 친환경적 식재설계에 관한 연구 -전남 영광 지역을 대상으로- (A Study of Naturally Favorable Planting Design in Irrigation Channels)

  • 김선주;정신혜;안민우
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.241-245
    • /
    • 2001
  • In this study, we designed irrigation channel which meet function of waterquality purification and landscape as well as waterquantity using planting in Sanggye-ri Yeomsan-myeon Yeounggwang-gun Jeollanam-do. First, according to hydrology characteristic, irrigation channel is designed dividing three zone flood control zone, river-friendliness facilities zone and naturally favorable zone. Second, for designing planting, criterion of selecting plant is established. As a result, we designed planting dividing segment to harmony regional characteristic and landscape.

  • PDF

발반사 마사지가 유방암 환자의 수술 후 통증과 수면만족도에 미치는 효과 (The Effects of Foot Reflex Zone Massage on Patients Pain and Sleep Satisfaction Following Mastectomy)

  • 박지원;유혜라;이홍숙
    • 가정간호학회지
    • /
    • 제13권1호
    • /
    • pp.54-60
    • /
    • 2006
  • This study, a quasi-experimental study using a nonequivalent control group pretest-posttest design. conducted a survey on 30 patients test group and control group of IS patients sampling an adjacent population at random - who are operated on the breast cancer and are in the A University Hospital located in Suwon, to examine into the effects of foot reflex zone massage on their pain and sleep satisfaction through the nursing interventions. It gave them a foot reflex zone massage for the total 30 minutes-basic massage 10 minutes and reflex massage 20 minutes required to alleviate their pain day in day out covering a two-month period from the first of July to the first of September 2004. for the purpose of collecting data. It launched into a two-round foot reflex zone massage at 6 and 24 hours since mastectomy through a direct visit at the hospital room to measure pain intensity, physiological index(pulse and blood pressure) and sleep satisfaction of them. The results are as follows. First, it showed that there is all the difference between pain intensity of test group and that of control group. In result, the first hypothesis, pain of test group. which measure at 6(p=.000) and 24 hours(p=.001) since mastectomies, will be bigger than that of control group, was established. Second, it showed that there is all the difference between physiological index of test group and that of control group. In result. the second hypothesis, pulse(p= .025, p= .002), systolic blood pressure(p= .004, p=.012) and diastolic blood pressure(p=.004. p= .003) of test group, which investigate at 6 and 24 hours since mastectomies, will be bigger than that of control group, was established. Third, it showed that there is a significant difference between sleep satisfaction of test group and that of control group(p=.000). In result, the fourth hypothesis, sleep satisfaction of test group. which examine in the morning after mastectomies, will be bigger than that of control group, was established. In the result. a foot reflex zone massage is seen to be effective in the pain reduction and sleep promotion of patients who are operated on breast cancer, and in providing them with more qualitative care by improving confidence between them and nurses through a physical touch. Also, it can be applied to a clinical examination through an independent nursing intervention.

  • PDF

온수배관을 이용한 시설딸기 부분난방기술 개발 (Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe)

  • 문종필;강금춘;권진경;백이;이태석;오성식;남명현
    • 한국농공학회논문집
    • /
    • 제58권5호
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

리커런트 신경회로망을 이용한 공압 로드레스 실린더의 정밀위치제어 (The Precision Position Control of the Pneumatic Rodless Cylinder Using Recurrent Neural Networks)

  • 노철하;김영식;김상희
    • 한국정밀공학회지
    • /
    • 제20권7호
    • /
    • pp.84-90
    • /
    • 2003
  • This paper develops a control method that is composed of the proportional control algorithm and the learning algorithm based on the recurrent neural networks (RNN) for the position control of a pneumatic rodless cylinder. The proportional control algorithm is suggested for the modeled pneumatic system, which is obtained easily simplifying the system, and the RNN is suggested for the compensation of the modeling errors and uncertainties of the pneumatic system. In the proportional control, two zones are suggested in the phase plane. One is the transient zone for the smooth tracking and the other is the small movement zone for the accurate position control with eliminating the stick-slip phenomenon. The RNN is connected in parallel with the proportional control for the compensation of modeling errors and frictions, compressibilities, and parameter uncertainties in the pneumatic control system. This paper experimentally verifies the feasibility of the proposed control algorithm for such pneumatic systems.