• Title/Summary/Keyword: Control Volume Energy

Search Result 293, Processing Time 0.032 seconds

Effects of Volute Throat Enlargement and Fluid Viscosity on the Performance of an Over Hung Centrifugal Pump

  • Khoeini, Davood;Riasi, Alireza;Shahmoradi, Ali
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.30-39
    • /
    • 2017
  • In the current study, identifying regimes and behaviors of the various viscous fluids in a typical horizontal single-stage centrifugal pump and improving its performance by enhancing volute throat area have been surveyed numerically and experimentally. Indeed the initial pump had insufficient head at BEP (Best Efficient Point) in relevant applications. In order to solve this problem, the method of increasing the volute throat area on the prototype was used in steps and eventually the increased head values have been achieved. Then modified centrifugal pump, that has been constructed based on the modified control volume from numerical results, has been tested thoroughly. The maximum head and efficiency discrepancy between numerical and experimental results in BEP were 1.4 and 2.6% respectively. The effects of viscous fluids, from 1 cSt to 500 cSt, on the performance curves of centrifugal pump have been investigated as well and results showed that viscous fluids has significant effect on them. Indeed the highest head and efficiency in the same conditions at BEP has been obtained in viscosity 1 cst which was by 19.2% and 44% greater than the viscosity 500 cSt. It is also found that the highest viscous fluid had the highest energy consumption as the absorbed power of highest viscous fluid, 500 cSt, increased up to approximately 55% above the lowest viscous fluid, 1 cSt, values.

The Studies on the Development of Radiation Pneumonitis and Its Related Factors (방사선폐렴의 발생과 촉진요인에 관한 고찰)

  • Suh, Hyun-Suk;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.119-129
    • /
    • 1987
  • With the introduction of X-rays of higher energy that have higher penetrability, it has become possible to treat the deep-seated tumor with increased local control rate. But at the same time it has incrased the damage to the deep seated organs, especially to the lung which is known to be the less radiotolerable tissue in the body. This study analyses the 66 patients who were exposed to the irradiation of the lung, and examines the development of radiation pneumonitis and its related factors. The results of the study are summarized as follows: 1, The 66 patients were consisted of 40 cases of lung cancer, 15 cases of breast cancer and 11 cases of mediastinal tumors. There were 37 males and 29 females with the male to female ratio 1.3: 1. A male to female ratio in the lung cancer was 3: 1. 2. Among 66 patients, 26 patients $(39\%)$ developed the radiographical changes of acute radiation pneumonitis and 13 out of 26 patients $(50\%)$ showed the clinical features of acute radiation pneumonitis. 3. The onest of acute radiation pneumonitis ranged from 10 days to 6 months after the completion of radiotherapy. 4. There was a statistically significant close relationship between the development of radiation pneumonitis and the radiation dose. 5. As the irradiated lung volume increased, the development of radiation pneumonitis increased. But the statistical significance was not strong. 6. The increased incidence of radiation pneumonitis was observed when the chemotherapy was given before or concomittantly with radiotherapy. 7 There was no significant correlation between the development of radiation pneumonitis and the age, smoking and the presence of underlying lung disease.

  • PDF

Self-Assembled ZnO Hexagonal Nano-Disks Grown by RF Sputtering

  • Jeong, Eun-Ji;Kim, Ji-Hyeon;Kim, Su-Jin;Gang, Hyeon-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.461-461
    • /
    • 2013
  • Over the last decade, zinc oxide (ZnO) thin films have attracted considerable attention owing to large band gap of 3.37 eV and large exciton binding energy of 60 meV at room temperature [1-3]. Recent interest in ZnO related researches has been switched into the fabrication and characterization of low-dimensional nanostructures, such as nano-wires and nano-dots that can be applicable to manufacture the optoelectronic devices such as ultraviolet lasers, light-emitting-diodes and detectors. Since the optical properties of ZnO nano-structures might be distinct from those of bulk materials or thin films, the low-dimensional phenomena should be examined further. In order to utilize such advanced optoelectronic devices, one of the challenges is how to control the surface state related emissions that are drastically increased with increasing the density of the nano-structures and the surface-to-volume ratio. This paper reports the synthesis and characterization of self-assembled ZnO hexagonal nano-disks grown by radio-frequency magnetron sputtering. X-ray diffraction data and scanning electron microscopy data showed that ZnO hexagonal nano-disks were nucleated on top of the flat surfaces as the film thickness reached to 1.56 ${\mu}m$ and then the number of nano-disks increased with increasing the film thickness. The lateral size of hexagonal nano-disks was ~720 nm and height was ~74 nm. The strong photo luminescence spectra obtained at 10 K was also observed, which was assigned to a surface exciton emission at 3.3628 eV arising from the surface sites of hexagonal nano-disks.

  • PDF

Effects of Na Restriction, K Supplement and Diuresis on Aldosterone Metabolic Clearance in the Normal Korean (한국인의 Aldosterone 대사 제거율에 미치는 Na 섭취제한, K 보충투여 및 이뇨의 영향)

  • Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.11 no.1
    • /
    • pp.37-44
    • /
    • 1977
  • In the previous study of the release, excretion, and plasma concentration of aldosterone in normal Koreans, the author found that urinary aldosterone excretion and aldosterone secretion rate of the Korean who usually take high amount of salt are significantly lower, in compared to Americans, although the plasma concentration is only tended to be low. The control of plasma aldosterone level depends on the secretion rate and the metabolic clearance of the hormone. In this experiments, the metabolic clearance rate of aldosterone was determined in normotensive korean and the effects of adrenal stimulations on the rates were also studied in the same subjects. The metabolic clearance rate of the normal Korean was not significantly different from those of the American, and shown a little increase in response to sodium restriction. These results indicate that the decrease in secretion rate rather than the increase in metabolic clearance Tate is the major factor maintaining lower plasma aldosterone level. After furosemide diuresis, on the contrary, the removal of aldosterone showed significant the decrease despite slight increase of secretion rate. This suggest that the reduction in metabolic clearance rate of the hormone during volume depletion found to be major cause of high plasma concentration. Additional potassium supply produced detectable decrease of metabolic clearance rate, but the changes were smaller than that of secretion rate, which suggested that the higher secretion rate could account for elevated plasma concentration of aldosterone rather than metabolic clearance. Above results also support author's previous evidences that the normal Korean who already adapted to a high sodium diet have ability to produce adequate aldosterone activity without producing detectable changes on the metabolic clearance rate under the condition of sodium restriction with approp riate potassium intake.

  • PDF

Increase in Voltage Efficiency of Picoinjection using Microfluidic Picoinjector Combined Faraday Moat with Silver Nanoparticles Electrode (은 나노입자 전극과 패러데이 모트를 이용한 미세유체 피코리터 주입기의 전압효율 상승)

  • Noh, Young Moo;Jin, Si Hyung;Jeong, Seong-Geun;Kim, Nam Young;Rho, Changhyun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.472-477
    • /
    • 2015
  • This study presents modified microfluidic picoinjector combined Faraday moat with silver nanoparticle electrode to increase electrical efficiency and fabrication yield. We perform simple dropping procedure of silver nanoparticles near the picoinjection channel, which solve complicate fabrication process of electrode deposition onto the microfluidic picoinjector. Based on this approach, the microfluidic picoinjector can be reliably operated at 180 V while conventional Faraday moat usually have performed above 260 V. Thus, we can reduce the operation voltage and increase safety. Furthermore, the microfluidic picoinjector is able to precisely control injection volume from 7.5 pL to 27.5 pL. We believe that the microfluidic picoinjector will be useful platform for microchemical reaction, biological assay, drug screening, cell culture device, and toxicology.

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

Failure Case Studies of Sensors for Electronic Controlled Engine in LPG Vehicle (LPG 자동차에서 전자제어엔진용 센서의 고장사례에 관한 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • The purpose of this paper analyzes and investigates the failure case studies of electronic control sensors for a LP gas engine. The malfunction of crank angle sensor, which controls a fuel injection volume of LP gas, displays an irregular and non-uniform pulse wave form. The pulse form, which is related to the noise of the crank angle sensor, displays at the rectangular peak with a saw-toothed shape and is intermittently generated with a level of 2.46V noise signal. The malfunction of No. 1 TDC sensor in which is caused from the internal disorder affects to the reduction of engine power and engine stop suddenly. If the malfunction of oxygen sensor is occurred due to a wiring problem of a sensor connector, the LP gas vehicle may produce a shaking and disharmony of an engine because of no signal supply from the oxygen sensor. The air cleaner replica produces the clogging of continuous supply of fresh air. This may cause the retardation of vehicle acceleration and engine disharmony intermittently.

Dynamic Soaring Optimal Path Following with Time-variant Horizontal Wind Model (시변 수평풍 모델을 적용한 동적 활공 최적 궤적 추종)

  • Park, SeungWoo;Han, SeungWoo;Kim, Linkeun;Ko, Sangho
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.5
    • /
    • pp.72-80
    • /
    • 2021
  • Albatross uses dynamic soaring technique to obtain energy from horizontal winds and fly long distances without flapping. These dynamic soaring technique can be applied to manned/unmanned aircraft to reduce the components required for the aircraft and achieve light weight and small volume to effectively perform a given task. In this paper, to simulate the dynamic soaring technique of Albatross, we defined the optimization problem and set each boundary condition to derive the optimal flight trajectory and carry out simulations to follow it. In particular, to model dynamic soaring simulations more closely with reality, we proposed a horizontal wind model that changes every moment. This identifies and analyzes the effect of the time-variable horizontal wind model on the dynamic soaring mission of unmanned aircraft.

Calcium annealing approach to control of surface groups and formation of oxide in Ti3C2Tx MXene

  • Jung-Min Oh;Su Bin Choi;Taeheon Kim;Jikwang Chae;Hyeonsu Lim;Jae-Won Lim;In-Seok Seo;Jong-Woong Kim
    • Advances in nano research
    • /
    • v.15 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Ti3C2Tx MXene, a 2D material, is known to exhibit unique characteristics that are strongly dependent on surface termination groups. Here, we developed a novel annealing approach with Ca as a reducing agent to simultaneously remove F and O groups from the surface of multilayered MXene powder. Unlike H2 annealing that removes F effectively but has difficulty in removing O, annealing with Ca effectively removed both O and F. X-ray photoelectron spectroscopy (XPS) and energy dispersive X-ray spectroscopy revealed that the proposed approach effectively removed F and O from the MXene powder. The results of O/N analyses showed that the O concentration decreased by 57.5% (from 2.66 to 1.13 wt%). In addition, XPS fitting showed that the volume fraction of metal oxides (TiO2 and Al2O3) decreased, while surface termination groups (-O and -OH) were enhanced, which could increase the hydrophilic and adsorption properties of the MXene. These findings suggest that when F and O are removed from the MXene powder, the interlayer spacing of its lattice structure increases. The proposed treatment also resulted in an increase in the specific surface area (from 5.17 to 10.98 m2/g), with an increase in oxidation resistance temperature in air from ~436 to ~667 ℃. The benefits of this novel technology were verified by demonstrating the significantly improved cyclic charge-discharge characteristics of a lithium-ion battery with a Ca-treated MXene electrode.

Impact of openings on the structural performance of ferrocement I-Beams under flexural loads

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ayman M. Elshaboury;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.90 no.4
    • /
    • pp.371-390
    • /
    • 2024
  • Investigating the impact of openings on the structural behavior of ferrocement I-beams with two distinct types of reinforcing metallic and non-metallic meshes is the primary goal of the current study. Up until failure, eight 250x200x2200 mm reinforced concrete I-beams were tested under flexural loadings. Depending on the kind of meshes used for reinforcement, the beams are split into two series. A control I-beam with no openings and three beams with one, two, and three openings, respectively, are found in each series. The two series are reinforced with three layers of welded steel meshes and two layers of tensar meshes, respectively, in order to maintain a constant reinforcement ratio. Structural parameters of investigated beams, including first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were reported. The number of mesh layers, the volume fraction of reinforcement, and the kind of reinforcing materials are the primary factors that vary. This article presents the outcomes of a study that examined the experimental and numerical performance of ferrocement reinforced concrete I-beams with and without openings reinforced with welded steel mesh and tensar mesh separately. Utilizing ANSYS-16.0 software, nonlinear finite element analysis (NLFEA) was applied to illustrate how composite RC I-beams with openings behaved. In addition, a parametric study is conducted to explore the variables that can most significantly impact the mechanical behavior of the proposed model, such as the number of openings. The FE simulations produced an acceptable degree of experimental value estimation, as demonstrated by the obtained experimental and numerical results. It is also noteworthy to demonstrate that the strength gained by specimens without openings reinforced with tensar meshes was, on average, 22% less than that of specimens reinforced with welded steel meshes. For specimens with openings, this value is become on average 10%.