• Title/Summary/Keyword: Control UI

Search Result 394, Processing Time 0.025 seconds

A STUDY ON THE SHEAR BOND STRENGTH OF COMPOMER ACCORDING TO SURFACE TREATMENT (Compomer의 치면처리방법에 따른 전단 결합 강도에 관한 연구)

  • Kim, Jin-Yong;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.247-256
    • /
    • 1998
  • To evalutate the change in shear bond strength according to dentin surface treatment, 4 materials were divided into control group(A) and experimental group(B). Group A was treated according to the instruction of manufacture. Group B was treated with 32% phosphoric acid. After dentin surface treatment, each material was bonded and stored in 100% humidity during 7 days, and then, the shear bond strength was evaluated. The results were as follows: 1. In the case of treatment according to the instruction of manufacture, the shear bond strength according to material showed Z-100 to be highest with 12.42 MPa, Compoglass had the lowest shear bond strength with 4.23 MPa and there was significant difference between Compoglass and Z-100, Dyract (p<0.01). 2. The group treated with 32% phosphoric acid showed lower shear bond strength than that of the group treated according to the instruction of manufacture but there was no statistical significance. 3. As a result of observation under SEM, the fracture pattern was a mixture of cohesive and adhesive failure in group 1, and there was more adhesive failure in group 2, and in group 3 and 4 there was cohesive failure of material or tooth structure. From the results above Dyract showed shear bond strength levels between resin and resin -modified glass ionomer but Compoglass showed much lower shear bond strength than that of resin-modified glass ionomer thus indicating that even though they are the same type of material they show evident differences in physical properties. And it is thought that the treatment of dentin surface with phosphoric acid did not increase the shear bond strength, unlike enamel.

  • PDF

Emission Characteristics of Air Pollutants from Meat Charbroiling (고기구이에서 발생하는 대기오염물질의 배출 특성)

  • Park, Seong Kyu;Kim, Dae kuen;Hwang, Ui Hyun;Lee, Jeong Joo;Lee, Jun bok;Bae, Il Sang;Eo, Soo-mi;Jung, Kweon
    • Journal of Climate Change Research
    • /
    • v.6 no.4
    • /
    • pp.311-318
    • /
    • 2015
  • Emission characteristics from charbroiling of four different meats (beef, port, duck and chicken) in a pilot-scale cooking facility were investigated in this study. The analyzed air pollutants include gaseous species (CO, NO, $SO_2$, $NH_3$ and PAHs) as well as particulate matters (TSP, $PM_{10}$, $PM_{2.5}$ and black carbon). The emission factors of $PM_{10}$ and PAHs were in the range of 3~47 g-PM/kg-meat and 0.6~11.41 mg-PAHs/kg-meat, respectively, depending on the type of a meat. In addition, the results also revealed that the high ratio of $PM_{2.5}$ to TSP in a meat charbroiling should be considered to design and to operate air pollution control devices.

Effect of Horticultural Media with Recycled Coir Substrates on Growth of Chinese Cabbage and Lettuce Crop (코이어 배지를 재활용한 혼합 상토가 배추 및 상추의 생육에 미치는 영향)

  • Lee, Gyu-Bin;Choe, Yun-Ui;Park, Eun-Ji;Park, Young-Hoon;Choi, Young-Whan;Son, Beung-Gu;Kang, Jum-Soon
    • Journal of Environmental Science International
    • /
    • v.27 no.11
    • /
    • pp.937-946
    • /
    • 2018
  • This study investigated the applicability of horticultural media with recycled coir substrates the growth of Chinese cabbage (Brassica campestris L. ssp. Pekinensis) and lettuce (Lactuca sativa L.) crop. The six different types of coir based substrates were A, Coir 45: Perlite 35: Vermiculite 12: Zeolite 8 (%), B, Coir 55: Perlite 25: Vermiculite 12: Zeolite 8 (%), C, Coir 65: Perlite 15: Vermiculite 12: Zeolite 8 (%), D, Coir 75: Perlite 5: Vermiculite 12: Zeolite 8 (%), E, Coir 85: Perlite 5: Vermiculite 5: Zeolite 5 (%) and F, nursery media (control). The pH and Electric conductivity of the horticultural nursery media were 6.06-7.00 and $0.45-1.10dS/m^{-1}$, respectively. The nursery media containing coir substrates had higher level of Total N, Ca, K, Mg and P than those without coir. Additionally, it was observed that the growth of Chinese cabbage was the best on D (containing 75% coir) while that of lettuce was the best on E (containing 85% coir). In general, when substrates containg a higher percentage of coir were used, the growth of Chinese cabbage and lettuce was ideal. Additionally, the P, Ca, and Mg content in both plants was not significantly altered by the amount of coir present in the media. However, with an increase in the amount of coir substrate, the chlorophyll, N, and K content was increased. After harvesting, there was no significant difference in the chemical properties of the horticultural nursery media of both plants. Thus, it can be suggested that, coir substrate after a single use could be recycled as horticulture nursery media.

Combined effects of a chemically cross-linked porcine collagen membrane and highly soluble biphasic calcium phosphate on localized bone regeneration

  • Kim, You-Kyoung;An, Yin-Zhe;Cha, Jae-Kook;Lee, Jung-Seok;Jung, Ui-Won;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.56 no.12
    • /
    • pp.667-685
    • /
    • 2018
  • Objectives: Aim of this study was to evaluate bone regenerative efficacy of a chemically cross-linked porcine collagen membrane (CM) when used in combination with highly soluble biphasic calcium phosphate (BCP). Materials and methods: Physiochemical properties of the experimental collagen membrane were analyzed. Four circumferential defects with diameter of 8 mm were created in each calvarium of New Zealand white rabbits (n = 10). Defects were randomly allocated to one of following 4 groups: 1) BCP-CM (BCP (20% hydroxyapatite/80% ${\beta}$-tricalcium phosphate) covered with the prepared collagen membrane), 2) BCP (only BCP used), 3) CM (only the prepared collagen membrane used), and 4) C (control; only blood clot). After 2 weeks (n = 5) and 8 weeks (n = 5), histologic and histomorphometric analyses were performed. Results: The experimental collagen membrane exhibited dense and compact structure, relatively high tensile strength and lower degradability. Histologic analyses revealed that new bone increased rapidly at 2 weeks, while defect was preserved at 8 weeks. Histomorphometric analyses revealed that the new bone areas increased in the BCP-grafted groups over 8 weeks, with BCP-CM exhibiting greater total augmented area than that of BCP group both at 2 weeks ($27.12{\pm}3.99$ versus $21.97{\pm}2.27mm^2$) and 8 weeks ($25.75{\pm}1.82$ versus $22.48{\pm}1.10mm^2$) (P < 0.05). Conclusions: The experimental collagen membrane successfully preserved localized defect for 8 weeks despite early rapid resorption of BCP. Within the study limitations, combined use of the chemically cross-linked porcine collagen membrane and highly soluble BCP aided localized bone regeneration.

  • PDF

Implementation of IoT System for Wireless Acquisition of Vibration and Environmental Data in Distributing Board (제진형 배전반의 진동 및 환경 데이터수집을 위한 IoT 시스템 구현)

  • Lee, Byeong-Yeong;Lee, Young-Dong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.199-205
    • /
    • 2021
  • The distributing board in directly installed on the ground or the bottom surface of the building, and when vibrations such as earthquakes or external shocks occur, the possibility of damage or malfunction of electric components such as internal power devices, wiring, and protection relays increases. Recently, the need for a seismic type distributing board is increasing, and research and development of a distributing board having a vibration damping function and product launch are being conducted. In this paper, an IoT-based data collection device system capable of measuring vibration and environmental data of distributing board was designed and implemented. When vibration occurred on the distributing board, data was stored and visualized in the MySQL DB through Node-RED for monitoring and data storage using the MQTT protocol for reliable messaging transmission. The test was conducted by attaching the IoT device of the distributing board, and data was collected in real-time and monitored through Node-RED.

Immediate implant placement in conjunction with guided bone regeneration and/or connective tissue grafts: an experimental study in canines

  • Lim, Hyun-Chang;Paeng, Kyeong-Won;Kim, Myong Ji;Jung, Ronald E.;Hammerle, Christoph HF.;Jung, Ui-Won;Thoma, Daniel S.
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.2
    • /
    • pp.170-180
    • /
    • 2022
  • Purpose: This study was conducted to assess the effect of hard and/or soft tissue grafting on immediate implants in a preclinical model. Methods: In 5 mongrel dogs, the distal roots of P2 and P3 were extracted from the maxilla (4 sites in each animal), and immediate implant placement was performed. Each site was randomly assigned to 1 of the following 4 groups: i) gap filling with guided bone regeneration (the GBR group), ii) subepithelial connective tissue grafting (the SCTG group), iii) GBR and SCTG (the GBR/SCTG group), and iv) no further treatment (control). Non-submerged healing was provided for 4 months. Histological and histomorphometric analyses were performed. Results: Peri-implant tissue height and thickness favored the SCTG group (height of periimplant mucosa: 1.14 mm; tissue thickness at the implant shoulder and ±1 mm from the shoulder: 1.14 mm, 0.78 mm, and 1.57 mm, respectively; median value) over the other groups. Bone grafting was not effective at the level of the implant shoulder and on the coronal level of the shoulder. In addition, simultaneous soft and hard tissue augmentation (the GBR/SCTG group) led to a less favorable tissue contour compared to GBR or SCTG alone (height of periimplant mucosa: 3.06 mm; thickness of peri-implant mucosa at the implant shoulder and ±1 mm from the shoulder: 0.72 mm, 0.3 mm, and 1.09 mm, respectively). Conclusion: SCTG tended to have positive effects on the thickness and height of the periimplant mucosa in immediate implant placement. However, simultaneous soft and hard tissue augmentation might not allow a satisfactory tissue contour in cases where the relationship between implant position and neighboring bone housing is unfavorable.

Unity Engine-based Underwater Robot 3D Positioning Program Implementation (Unity Engine 기반 수중 로봇 3차원 포지셔닝 프로그램 구현)

  • Choi, Chul-Ho;Kim, Jong-Hun;Kim, Jun-Yeong;Park, Jun;Park, Sung-Wook;Jung, Se-Hoon;Sim, Chun-Bo
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.64-74
    • /
    • 2022
  • A number of studies related to underwater robots are being conducted to utilize marine resources. However, unlike ordinary drones, underwater robots have a problem that it is not easy to locate because the medium is water, not air. The monitoring and positioning program of underwater robots, an existing study for identifying underwater locations, has difficulty in locating and monitoring in small spaces because it aims to be utilized in large spaces. Therefore, in this paper, we propose a three-dimensional positioning program for continuous monitoring and command delivery in small spaces. The proposed program consists of a multi-dimensional positioning monitoring function and a ability to control the path of travel through a three-dimensional screen so that the depth of the underwater robot can be identified. Through the performance evaluation, a robot underwater could be monitored and verified from various angles with a 3D screen, and an error within the assumed range was verified as the difference between the set path and the actual position is within 6.44 m on average.

Flood Response Disaster Prevention Facility Simulator Design and Prototype Development Using Spill and Inundation Model (유출·침수모델을 이용한 홍수대응 방재시설 시뮬레이터 설계 및 프로토타입 개발)

  • Seo, Sung Chul;Kim, Ui Hwan;Park, Hyung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.259-266
    • /
    • 2023
  • Global climate change is increasing, and the damage and scale of localized torrential rains are increasing. Pre-flood analysis simulation results should be derived from rainfall data through rainfall forecasts to prevent flood damage. In addition, it is necessary to control the use and management of flood response disaster prevention facilities through immediate decision-making. However, methods using spills and flood models such as XPSWMM and GATE2018 are limited due to professional usability and complex analytical procedures. Prototype (flood disaster prevention facility simulator) of this study is developed by calculating rainfall (short-term and long-term) using CBD software development methods. It is also expected to construct administrator and user-centric interfaces and provide GIS and visible data (graphs, charts, etc.).

Analysis of the peak particle velocity and the bonding state of shotcrete induced by the tunnel blasting (발파시 터널 숏크리트의 최대입자속도와 부착상태평가 분석)

  • Hong, Eui-Joon;Chang, Seok-Bue;Song, Ki-Il;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.247-255
    • /
    • 2010
  • Bonding strength of shotcrete is a significant influential factor which plays the role of collapse prevention of tunnel crown and of debonding prevention of shotcrete induced by the blasting vibration. Thus, the evaluation of the shotcrete bonding state is one of the core components for shotcrete quality control. In this study, the peak particle velocities induced by blasting were measured on the shotcrete in a tunnel construction site and its effect on the bonding state of shotcrete is investigated. Drilling and blasting technique was used for the excavation of intersection tunnel connecting the main tunnel with the service tunnel. Blast-induced vibrations were monitored at some points of the main tunnel and the service tunnel. The shotcrete bonding state was evaluated by using impact-echo test coupled with the time-frequency domain analysis which is called short-time Fourier transformation. Analysis results of blast-induced vibrations and the time-frequency domain impact-echo signals showed that the blasting condition applied to the excavation of intersection tunnel hardly affects on the tunnel shotcrete bonding state. The general blasting practice in Korea was evaluated to have a minor negative impact on shotcrete quality.

Effect of the Non-Elastic Taping Method of Controlling Internal Hip Joint Rotation on Hip Muscle Activity: A Preliminary Study (엉덩관절 안쪽돌림 조절을 위한 비탄력 테이핑 방법이 엉덩관절 근활성도에 미치는 영향 -예비연구-)

  • Song-Ui Bae;Ju-Hyeon Jung;Dong-Chul Moon
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.281-289
    • /
    • 2023
  • Purpose: This study investigated the effects of the non-elastic taping method for controlling internal hip joint rotation on internal and external hip rotator muscle activity in healthy people. Methods: In this study, 18 healthy volunteers were instructed to perform the small knee bending (SKB) test. All participants completed the test following two methods (using non-elastic taping and not using taping). Muscle activation during the two methods was measured using a surface electromyography (EMG) device. Surface EMG data were collected from the gluteus medius, gluteus maximus, and tensor fasciae femoris muscles while performing the SKB test with and without non-elastic taping. Results: Muscle activity in the gluteus maximus was significantly higher during the SKB test with non-elastic taping than during the conventional SKB test with taping (p < 0.05). Tensor fasciae latae muscle activity was lower during the SKB test with non-elastic taping than during the conventional SKB test (p < 0.05). Conclusion: The findings suggest that the non-elastic taping method for controlling internal hip joint rotation effectively activates the hip's external rotator muscles and minimizes unwanted internal rotator muscle use during the SKB test. Therefore, the non-elastic taping method for controlling internal hip joint rotation could be an effective intervention for those who cannot control the internal rotation of their hips.