• 제목/요약/키워드: Control Loading System

검색결과 530건 처리시간 0.024초

합성가스(Reforming gas)를 이용한 멀티채널 CDPF의 재생 특성 연구 (Studies on Reforming Gas Assisted Regeneration of Multi-channel Catalyzed DPF)

  • 최광춘;정진화;송순호;전광민
    • 한국자동차공학회논문집
    • /
    • 제19권3호
    • /
    • pp.138-145
    • /
    • 2011
  • Diesel particulate filter (DPF) systems are being used to reduce the particulate matter emission of diesel vehicles. The DPF should be regenerated after certain driving hours or distance to eliminate soot in the filter. The most widely used method is active regeneration with oxygen at $550{\sim}650^{\circ}C$. Syngas (synthetic gas) can be used to lower the regeneration temperature of Catalyzed DPF (CDPF). The syngas is formed by fuel reforming process of CPOx (Catalytic Partial Oxidation) at specific engine condition (1500rpm, 2bar) using 1wt.% $Rh/CeO_2-ZrO_2$ catalyst. The oxidation characteristics of PM with syngas supplied to filter were studied using partial flow system that can control temperature and flow rate independently. The filter is coated with washcoat loading of $25g/ft^3$ $Pt/Al_2O_3-CeO_2$, and multi-channel CDPF (MC-CDPF) was used. The filter regeneration experiments were performed to investigate the effect of syngas exothermic reaction on soot oxidation in the filter. For this purpose, before oxidation experiment, PM was collected about 8g/L to the filter at engine condition of 1500rpm, bmep 8bar and flow temperature of $200^{\circ}C$ Various conditions of temperature and concentration of syngas were used for the tests. Regeneration of filter started at 2% $H_2$ and CO concentration respectively and inlet temperature of $260^{\circ}C$. Filter Regeneration occurs more actively as the syngas concentration becomes higher.

흡연자와 비흡연자의 행동양상 연구 (A Study on Behavior Patterns Between Smokes and Non-Smokers)

  • 김화신
    • 대한간호학회지
    • /
    • 제20권1호
    • /
    • pp.79-87
    • /
    • 1990
  • Clinical and epedemiologic studies of coronary heart disease(CHD)have from time to time over the last three decades found associations between prevalence of CHD and behavioral attributes and cigarette smoking. The main purpose of this study is reduced to major risk factor of coronary heart disease through prohibition of smoking and control of behavior pattern. The subjects consisted of 120 smokers and 90 non-smokers who were married men older than 30 years working in officers. The officers were surveyed by means of questionnaire September 26 through October 6, 1989. The Instruments used for this study was a self-administered measurement tool composed of 59 items was made through modifications of Jenkuns Activity Survery(JAS). The Data were analysed by SAS(Statistical Analsis System) program personal computer. The statistical technique used for this study were Frequency, x$^2$-test, t-test, ANOVA, Pearson Correlation Coefficient. The 15 items were chosen with items above 0.3 of the factor loading in the factor analysis. In the first factor analysis 19 factors were extracted and accounted for 86% of the total variance. However when the number of factors were limited to 3 in order to derive Jenkins classification, three factors were derived. There names are Job-Involvement, Speed & Impatience, Hard-Driving. Each of them includes 21 items, 21 and 9, respectively. The results of this study were as follow : 1. The score of the smoker group and non-smoker group in Job-Involvement(t=5.7147, p<0.0001), Speed & Impatience(t=4.6756, p<.0001), Hard-Driving(t=8.0822, p<.0001) and total type A behavior pattern showed statistically significant differences(t=8.1224, p<.0001). 2. The score of type A behavior pattern by number of cigarettes smoked daily were not statistically significant differences. 3. The score of type A behavior pattern by duration of smoking were not significant differences. It was concluded that the relationship between smokers and non - smokers of type A behavior pattern was statistically significant difference but number of cigarettes smoked daily and duration of smoking were not significant differences. Therefore this study is needed to adequate nursing intervention of type A behavior pattern in order to elevated to educational effect for prohibition of cigarette smoking.

  • PDF

염료 분해균 증대를 통한 Pilot Plant에서의 담체 내 미생물 생태와 색도처리에 미치는 영향 (Effect of Dye-Degrading Microbes' Augmentation on Microbial Ecosystem of the Fluidizing Media and Color Treatment in a Pilot Plant)

  • 김정태;이건;박도현;강경환;김중균;이상준
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.681-695
    • /
    • 2014
  • In a pilot-scale dyeing wastewater treatment using two-type fluidizing media, each thickness of biofilm was 15 and 30 ${\mu}m$, respectively. The numbers of protozoa inhabited in small-size (PEMT A) and big-size (PEMT B) media were $7.5{\times}10^4$ and $1.25{\times}10^5$ cells/ml, respectively, and dominant species were Entosiphon sulcatus var sulcatus in PEMT A and Chlamydomonas reinhardtii in PEMT B, respectively. Flask experiments using the two media revealed that the percentages of color removal were 25.8% in PEMT A and 27.1% in PEMT B after 72-h cultivation, indicating the necessity of bioaugmentation. Experiments for bioaugmentation effect on color removal were carried out in the pilot-scale treatment for 75 d by three-step operation under the control of wastewater loading rate and microbial input rate. Dye degradation occurred mainly in the second reaction tank, and the attachment of augmented dye-degrading microorganisms to media took at least 35 d. Final value of chromaticity in effluent was 227, meeting the required standard. Therefore bioaugmentation onto media was good for color treatment. In summary, thickness of biofilm formed on the media depended upon the size of media, resulting in different ecosystem inside the media. Hence, this affected microbial community and color treatment further. Accordingly, the reduction of operation cost is expected by efficient color-treatment process using bioaugmented media.

골 재흡수 치료를 위한 파미드로네이트를 함유한 이식형 생분해성 PLGA 웨이퍼의 제조와 특성결정 (Preparation and Characterization of Pamidronate-loaded PLGA Wafer for the Treatment of Bone Resorption)

  • 유제영;김상욱;강길선;성하수;정제교
    • 폴리머
    • /
    • 제26권5호
    • /
    • pp.680-690
    • /
    • 2002
  • 골 재흡수 치료를 목적으로 파미드로네이트를 지속적으로 방출하는 제형으로 제조하기 위하여 락타이드-글리콜라이드 공중합체 (PLGA, 락타이드 : 글리콜라이드 몰비 = 75 : 25, 분자량 20000 g/mole 및 90000 g/mole)를 이용하여 직접압축 성형방법으로 생분해성 웨이퍼를 제조하였다. 약물과 고분자의 함량비 웨이퍼의 두께, PLGA 분자량 등을 조절하여 PLGA 웨이퍼를 제조하였고 이들의 형태학적 특성과 방출거동 및 분해거동을 살펴보았다. 웨이퍼의 제조는 혼합된 분말을 웨이퍼 제작용 몰드에 넣은 후 프레스를 이용하여 일정 압력으로 일정시간 동안 상온에서 가압하여 제조하였다. 제조된 웨이퍼는 약물의 초기함량이 증가할수록 방출속도가 빠르게 나타났으며, 제형의 두께가 두꺼워질수록 시간이 경과함에 따라 약물의 방출속도가 증가하였다. 또한 고분자의 분자량이 큰 것이 작은 것에 비해 상대적으로 초기 약물 방출량이 적고 방출되는 속도 또한 느려져. 저분자보다 오랫동안 약물이 방출되었다. 이러한 약물전달 시스템은 압축성형방법에 의해 제조하므로 제조가 간단하고 약물방출속도를 정확하게 제어할 수 있으므로 이식을 위한 제형으로 제조시 유용하게 쓰일 것으로 예상되었다.

오염하천의 정화를 위한 파일럿 규모의 인공습지 적용 (Performance Study on Pilot-scale Constructed Wetlands in order to Restore Contaminated Stream)

  • 김승준;최용수;배우근
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.546-556
    • /
    • 2006
  • The purpose of this study is to improve the polluted stream water quality by pilot-scale five different constructed wetlands (CWs). Cell 1 to 3 are newly designed 2SFCW (Surface-subsurface flow CW) with 1 to 3 flow shifters (FS) in the middle of the wetland system. Cell 4 and 5 are control CW (CCW), but Cell 5 is the same type as Cell 3. The FS, which converts the route of surface and subsurface flow between two wetlands connected in series, was able to enhance the treatability of TN via nitrification and denitrification and of SS due to filtration and sedimentation. The void fraction and dispersion number of Cell 1, 2 and 3 obtained from the RTD analysis were found to be 0.73 and 0.17, respectively. COD and TP removal efficiencies of Cell 1 to 3 were similar to that of Cell 4 and 5. SS removal efficiencies of Cell 1 to 3 and 5 with FS were 5-10% higher than that of Cell 4 without FS. TN removal efficiencies of Cell 1 to 3 were 3-14% higher than that of Cell 4 and 5. The average $R^2$ values of COD, SS, TN and TP obtained from nonlinear regression analysis were similar to the results of other researchers.

Static and dynamic characterization of a flexible scaled joined-wing flight test demonstrator

  • Carregado, Jose;Warwick, Stephen;Richards, Jenner;Engelsen, Frode;Suleman, Afzal
    • Advances in aircraft and spacecraft science
    • /
    • 제6권2호
    • /
    • pp.117-144
    • /
    • 2019
  • High Altitude and Long Endurance (HALE) aircraft are capable of providing intelligence, surveillance and reconnaissance (ISR) capabilities over vast geographic areas when equipped with advanced sensor packages. As their use becomes more widespread, the demand for additional range, endurance and payload capability will increase and designers are exploring non-conventional configurations to meet the increasing demands. One such configuration is the joined-wing concept. A joined-wing aircraft is one that typically connects a front and aft wings in a diamond shaped planform. One such example is the Boeing SensorCraft configuration. While the joined-wing configuration offers potential benefits regarding aerodynamic efficiency, structural weight, and sensing capabilities, structural design requires careful consideration of elastic buckling resulting from the aft wing supporting, in compression, part of the forward wing structural loading. It has been shown already that this is a nonlinear phenomenon, involving geometric nonlinearities and follower forces that tend to flatten the entire configuration, leading to structural overload due to the loss of the aft wing's ability to support the forward wing load. Severe gusts are likely to be the critical design condition, with flight control system interaction in the form of Gust Load Alleviation (GLA) playing a key role in minimizing the structural loads. The University of Victoria Center for Aerospace Research (UVic-CfAR) has built a 3-meter span scaled and flexible wing UAV based on the Boeing SensorCraft design. The goal is to validate the nonlinear structural behavior in flight. The main objective of this research work is to perform Ground Vibration Tests (GVT) to characterize the dynamic properties of the scaled flight vehicle. Results from the experimental tests are used to characterize the modal dynamics of the aircraft, and to validate the numerical models. The GVT results are an important step towards a safe flight test program.

고정밀 레이저 스크라이버 장비의 공정 시뮬레이션 분석에 관한 연구 (A Study on the Process Simulation Analysis of the High Precision Laser Scriber)

  • 최현진;박기진
    • 한국기계가공학회지
    • /
    • 제18권7호
    • /
    • pp.56-62
    • /
    • 2019
  • The high-precision laser scriber carries out scribing alumina ceramic substrates for manufacturing ultra-small chip resistors. The ceramic substrates are loaded, aligned, scribed, transferred, and unloaded. The entire process is fully automated, thereby minimizing the scribing cycle time of the ceramic substrates and improving the throughput. The scriber consists of the laser optical system, pick-up module of ceramic substrates, pre-alignment module, TH axis drive work table, automation module for substrate loading / unloading, and high-speed scribing control S/W. The loader / unloader unit, which has the greatest influence on the scribing cycle time of the substrates, carries the substrates to the work table that carries out the cutting line work by driving the X and Y axes as well as by adsorbing the ceramic substrates. The loader / unloader unit consists of the magazine up / down part, X-axis drive part for conveying the substrates to the left and right direction, and the vision part for detecting the edge of the substrate for the primary pre-alignment of the substrates. In this paper, the laser scribing machining simulation is performed by applying the instrument mechanism of each component module. Through this study, the scribing machining process is first verified by analyzing the process operation and work area of each module in advance. In addition, the scribing machining process is optimized by comparing and analyzing the scribing cycle time of one ceramic substrate according to the alignment stage module speed.

Study on failure behaviors of mixed-mode cracks under static and dynamic loads

  • Zhou, Lei;Chen, Jianxing;Zhou, Changlin;Zhu, Zheming;Dong, Yuqing;Wang, Hanbing
    • Geomechanics and Engineering
    • /
    • 제29권5호
    • /
    • pp.567-582
    • /
    • 2022
  • In the present study, a series of physical experiments and numerical simulations were conducted to investigate the effects of mode I and mixed-mode I/II cracks on the fracture modes and stability of roadway tunnel models. The experiments and simulations incorporated different inclination angle flaws under both static and dynamic loads. The quasi-static and dynamic testing were conducted by using an electro-hydraulic servo control device and drop weight impact system (DWIS), and the failure process was simulated by using rock failure process analysis (RFPA) and AUTODYN software. The stress intensity factor was also calculated to evaluate the stability of the flawed roadway tunnel models by using ABAQUS software. According to comparisons between the test and numerical results, it is observed that for flawed roadways with a single radical crack and inclination angle of 45°, the static and dynamic stability are the lowest relative to other angles of fractured rock masses. For mixed-mode I/II cracks in flawed roadway tunnel models under dynamic loading, a wing crack is produced and the pre-existing cracks increase the stress concentration factor in the right part of the specimen, but this factor will not be larger than the maximum principal stress region in the roadway tunnel models. Additionally, damage to the sidewalls will be involved in the flawed roadway tunnel models under static loads.

Full structure pseudo-dynamic test method and application based on OpenSees-OpenFresco-MTS

  • Zhen Tian;Yuan Cheng;Xuechong Ren;Mengmeng Yang
    • Structural Monitoring and Maintenance
    • /
    • 제11권3호
    • /
    • pp.173-185
    • /
    • 2024
  • Currently, the electro-hydraulic servo loading control system manufactured by MTS, OpenFresco hybrid test interface software and OpenSees finite element software are widely used in structure laboratories to carry out hybrid test, but there is no relevant public information about full structure pseudo-dynamic test based on the above software and hardware. In order to study the feasibility of using the above software and hardware to carry out full structure pseudo-dynamic test, the full structure pseudo-dynamic virtual experiments of a single degree of freedom (SDOF) structure and a two degrees of freedom (2DOFs) structure are carried out based on the MTS 793 Demo Mode, and the results are respectively compared with the finite element analysis method. The results show that the finite element analysis results and full structure pseudo-dynamic virtual experiment results are highly consistent, which verifies the feasibility of carrying out the full structure pseudo-dynamic test based on the above software and hardware. Then, a three story steel frame full structure pseudo-dynamic test is conducted, and the smooth implementation of full structure pseudo-dynamic test of the three story steel frame further verifies the reliability of thistesting method. The implementation method of carrying out the full structure pseudo-dynamic tests are introduced in detail, which can provide some reference for relevant research.

한강수계 비점오염원 저감시설의 생애주기비용 평가 (Lifecycle cost assessment of best management practices for diffuse pollution control in Han River Basin)

  • 이소영;;이정용;문현생;김이형
    • 한국습지학회지
    • /
    • 제18권4호
    • /
    • pp.448-455
    • /
    • 2016
  • 환경부는 비점오염원 관리를 위해 시범사업으로 12개의 비점오염 저감시설을 경안천 유역에 설치하였으며, 2006년부터 모니터링이 시작되었다. 본 연구는 비점오염 저감시설의 오염부하량, 저감효율, 유지관리 활동 등의 장기간 수행된 모니터링 결과를 바탕으로 각 시설의 경제성을 평가하기 위해 수행되었으며, 생애주기비용(Lifecycle cost, LCC)을 분석하였다. 비점오염 저감시설의 유지관리는 시설경관을 향상시키기 위한 심미적 관리가 중점적으로 수행된 것으로 나타났으며, 저류형 시설(Retention Pond, RP)이 년간 8,483$, 침투형 시설(Infiltration System, IS)이 8,888$로 대부분 비슷한 비용이 발생한 것으로 분석되었다. LCC는 인공습지(Constructed Wetland, CW)가 가장 높은 것($418,324)으로 나타났으며, 반면에 식생형 시설(Vegetated System, VS)이 가장 낮은 것($210,418)으로 분석되었다. 본 연구에서 조사된 비점오염 저감시설의 LCC와 하수처리장 등 수질처리시설의 LCC를 비교한 결과 비점오염 저감시설이 낮은 것으로 나타났다. 한편, 처리용량 대비 생애주기비용이 높아질수록 TSS와 TN의 저감효율은 높아지는 것으로 나타났다. 이러한 연구결과는 비용효율적인 비점오염 저감시설을 설계하는데 유용하게 활용될 것으로 기대되며, 향후 LCC 모델의 기초자료에도 활용될 수 있을 것으로 판단된다.