• Title/Summary/Keyword: Control & Monitoring system

Search Result 2,986, Processing Time 0.031 seconds

Performance Evaluation of Combined Sewer Overflow Treatment using Filtration Pilot Device (파일럿 여과장치를 이용한 합류식하수관 월류수 처리성능 평가)

  • Lee, Jun Ho;Shin, Young Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.5
    • /
    • pp.409-417
    • /
    • 2019
  • In this study, a $480m^3/day$ pilot device was constructed through laboratory experiments based on the Ministry of Environment manual. The purpose of this study was to analyze the characteristics of CSO treatment and backwashing characteristics by applying the pilot device to the field. The purpose of this study was to acquire the basic data necessary for the design and operation management of the real scale filtration type non-point pollution control system. The filtration was conducted while maintaining the linear velocity of 20m/hour. The CSO treatment efficiencies of the pilot devices were 0.4-76.1%(mean 49.0 %), SS 51.4-91.6%(mean 77.8%), COD 22.2-59.4% (mean 38.3%) and TP 14.5-52.6%(mean 38.1%),respectively. The correlation coefficient between SS and the turbidity of influent water was 0.90, higher than that of CSO. To operate the treatment system effectively, the turbidity can be easily measured in real time as the monitoring item is the most appropriate because SS is the main target substance of the non-point source. As a result of analyzing the adsorbent treatment characteristics of PP filter material applied to this pilot device, the average particle diameter range of influent was $4.6-40.1{\mu}m$(mean $21.2{\mu}m$) and the treated water was $0.9-24.5{\mu}m$(mean $6.4{\mu}m$), respectively. Particles of approximately 10m or less are leached out, and so it is necessary to compensate for the raw water containing micro particulate matter.

Implementation of IoT System for Wireless Acquisition of Vibration and Environmental Data in Distributing Board (제진형 배전반의 진동 및 환경 데이터수집을 위한 IoT 시스템 구현)

  • Lee, Byeong-Yeong;Lee, Young-Dong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.199-205
    • /
    • 2021
  • The distributing board in directly installed on the ground or the bottom surface of the building, and when vibrations such as earthquakes or external shocks occur, the possibility of damage or malfunction of electric components such as internal power devices, wiring, and protection relays increases. Recently, the need for a seismic type distributing board is increasing, and research and development of a distributing board having a vibration damping function and product launch are being conducted. In this paper, an IoT-based data collection device system capable of measuring vibration and environmental data of distributing board was designed and implemented. When vibration occurred on the distributing board, data was stored and visualized in the MySQL DB through Node-RED for monitoring and data storage using the MQTT protocol for reliable messaging transmission. The test was conducted by attaching the IoT device of the distributing board, and data was collected in real-time and monitored through Node-RED.

Attack Detection Technology through Log4J Vulnerability Analysis in Cloud Environments (클라우드 환경에서 Log4J 취약점 분석을 통한 공격 탐지 기술)

  • Byeon, Jungyeon;Lee, Sanghee;Yoo, Chaeyeon;Park, Wonhyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.557-559
    • /
    • 2022
  • The use of open source has the advantage that the development environment is convenient and maintenance is easier, but there is a limitation in that it is easy to be exposed to vulnerabilities from a security point of view. In this regard, the LOG4J vulnerability, which is an open source logging library widely used in Apache, was recently discovered. Currently, the risk of this vulnerability is at the 'highest' level, and developers are using it in many systems without being aware of such a problem, so there is a risk that hacking accidents due to the LOG4J vulnerability will continue to occur in the future. In this paper, we analyze the LOG4J vulnerability in detail and propose a SNORT detection policy technology that can detect vulnerabilities more quickly and accurately in the security control system. Through this, it is expected that in the future, security-related beginners, security officers, and companies will be able to efficiently monitor and respond quickly and proactively in preparation for the LOG4J vulnerability.

  • PDF

Modal parameter identification of tall buildings based on variational mode decomposition and energy separation

  • Kang Cai;Mingfeng Huang;Xiao Li;Haiwei Xu;Binbin Li;Chen Yang
    • Wind and Structures
    • /
    • v.37 no.6
    • /
    • pp.445-460
    • /
    • 2023
  • Accurate estimation of modal parameters (i.e., natural frequency, damping ratio) of tall buildings is of great importance to their structural design, structural health monitoring, vibration control, and state assessment. Based on the combination of variational mode decomposition, smoothed discrete energy separation algorithm-1, and Half-cycle energy operator (VMD-SH), this paper presents a method for structural modal parameter estimation. The variational mode decomposition is proved to be effective and reliable for decomposing the mixed-signal with low frequencies and damping ratios, and the validity of both smoothed discrete energy separation algorithm-1 and Half-cycle energy operator in the modal identification of a single modal system is verified. By incorporating these techniques, the VMD-SH method is able to accurately identify and extract the various modes present in a signal, providing improved insights into its underlying structure and behavior. Subsequently, a numerical study of a four-story frame structure is conducted using the Newmark-β method, and it is found that the relative errors of natural frequency and damping ratio estimated by the presented method are much smaller than those by traditional methods, validating the effectiveness and accuracy of the combined method for the modal identification of the multi-modal system. Furthermore, the presented method is employed to estimate modal parameters of a full-scale tall building utilizing acceleration responses. The identified results verify the applicability and accuracy of the presented VMD-SH method in field measurements. The study demonstrates the effectiveness and robustness of the proposed VMD-SH method in accurately estimating modal parameters of tall buildings from acceleration response data.

Current Status and Future Direction of the NIMS/KMA Argo Program (국립기상과학원 Argo 사업의 현황 및 추진 방향)

  • Baek-Jo Kim;Hyeong-Jun Jo;KiRyong Kang;Chul-Kyu Lee
    • Atmosphere
    • /
    • v.33 no.5
    • /
    • pp.561-570
    • /
    • 2023
  • In order to improve the predictability of marine high-impacts weather such as typhoon and high waves, the marine observation network is an essential because it could be rapidly changed by strong air-sea interaction. In this regard, the National Institute of Meteorological Sciences, Korea Meteorological Administration (NIMS/KMA) has promoted the Argo float observation program since 2001 to participate in the International Argo program. In this study, current status and future direction of the NIMS/KMA Argo program are presented through the internal meeting and external expert forum. To date, a total of 264 Argo floats have been deployed into the offshore around the Korean Peninsula and the Northwestern Pacific Ocean. The real-time and delayed modes quality control (QC) system of Argo data was developed, and an official regional data assembling center (call-sign 'KM') was run. In 2002, the Argo homepage was established for the systematic management and dissemination of Argo data for domestic and international users. The future goal of the NIMS/KMA Argo program is to improve response to the marine high-impacts weather through a marine environment monitoring and observing system. The promotion strategy for this is divided into four areas: strengthening policy communication, developing observation strategies, promoting utilization research, and activating international cooperation.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

Bio-floc technology application in olive flounder, Paralichthys olivaceus aquaculture according to the difference of closed recirculating systems (바이오플락 기술을 활용한 순환침전시스템에 따른 넙치(Paralichthys olivaceus)의 양성)

  • Cho, Yeong-Rok;Kim, Hyun-Soo;Kim, Su Kyoung;Kim, Su-Kyoung;Kim, Seok-Ryel;Hur, Young Baek;Kim, Jun-Hwan
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.2
    • /
    • pp.129-135
    • /
    • 2019
  • Juvenile Paralichthys olivaceus (mean weight 685.3±36.7 g) were raised in different and closed recirculating bio-floc system (control, bio-ball, and shelter) for 7 months. The water environment such as water temperature, dissolved oxygen, salinity, pH, and alkalinity according to the difference of closed recirculating system remained stable during the rearing period. No significant changes were observed in dissolved inorganic nitrogen such as ammonia, nitrite, and nitrate were observed in different closed recirculation system. The final weights according to the difference of closed recirculating were 1,524 g (control), 1,674 g (bio-ball), and 1,630 g (shelter). The survival rate was higher than 98%, and the final FCRs (Feed coefficient ratio) were 1.2, 1.1, and 1.2. The results of this study indicated high growth and survival rate in all systems.

Development of Intelligent Compaction System for Efficient Quality Control (효율적 품질관리를 위한 지능형 다짐 시스템 개발)

  • Lee, Soomin;Park, Sangil;Lee, Riho;Seo, Jongwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.751-760
    • /
    • 2018
  • Currently, the quality measurement of the work is carried out by the supervisor's visual inspection, as the workers individually judge the number of resolutions, thickness, speed and vibration. After work, we are conducting follow-up work through traditional spot test, which is less representative. Therefore, it is impossible to check the results of the resolution, and there is always the possibility that problems will arise due to poor construction. This study demonstrates the feasibility of using the continuous compaction strength measurement method by comparing the continuous compaction strength measurement method and the conventional compaction strength measurement method after performing the compaction in the actual field scale in various test conditions. The validity is verified by analyzing the Compaction Meter Value of an Intelligent Compaction roller composed of a Global Positioning System and an accelerometer, Based on the proven results, a full range of quality can be confirmed without a single test. The quality confirmation is visualized in the compaction control program developed in this study, This enables the field manager to perform real-time quality monitoring at the same time as compaction.

Study on Improving the System for the Revitalization and Efficient Management of the Local Commercial Area (지역상권 활성화 및 효율적 관리를 위한 제도 개선방안 연구)

  • Kim, Seung-Hee;Kim, Young-Ki
    • Journal of Distribution Science
    • /
    • v.11 no.5
    • /
    • pp.55-62
    • /
    • 2013
  • Purpose - This study aims to determine the problems and limitations of the Commercial Area Activation System, which was created by a special law for promoting traditional markets and shopping districts to revitalize and efficiently manage the central commercial area in different regions. We also suggest different options for its improvement. Research design, data, and methodology - We also look into the problems of which is being promoted as a demonstration project, from the aspects of legal text and guidelines. Results - The current commercial area activation system has several problems. First, the establishment of a comprehensive basic plan on the commercial area activation is not a requirement. Second, the benefit principle should be established to prevent the moral laxity of merchants who serve important roles in the main components of the commercial area activation business when they conduct their business. Third, the current special law constrains the commercial management organization, as under the civil law yields a limitation on finding a profitable business model. Fourth, to efficiently, constructing a system that links the other central government businesses and is needed. into a regional development budget or a budget for funding small businesses that the central government can control, which is effective. Further, we offer some suggestions for medium- and long-term policies. First, an integrated coordination mechanism at the central office level should be installed while setting the basic policy to revitalize the Based on this policy, local governments need a system that exclusively based on the after establishing a comprehensive plan for urban regeneration and getting approval from the integration organization. Second, a system that enables an understanding of the problems with business promotion by monitoring the procedure of supporting projects and regularly assessing business achievements is needed. Third, a plan is needed for resolving conflicts between various interested parties that adopts the commercial area activation system for carrying out a total redevelopment of the commercial area where small shops are densely located. A market maintenance project has been conducted as a means to recover our traditional market, which was economically depressed, and to revive the local economy, but it is mostly conducted in the form of reconstruction or redevelopment and represents the interests of landowners and merchants. Thus, it is most likely to lead to a gradual disappearance of traditional markets. Conclusions - This study looks primarily into the problems that appeared in the legal text or the guidelines regarding the direction of improvement of the commercial area activation business that has been going on as a demonstration project since 2011 and suggests some solutions.

  • PDF