• 제목/요약/키워드: Contrast-enhanced ultrasound (CEUS)

검색결과 20건 처리시간 0.022초

Hepatic Angiomyolipoma: Contrast Patterns with SonoVue-enhanced Real-time Gray-scale Ultrasonography

  • Wei, Rui-Xue;Wang, Wen-Ping;Ding, Hong;Huang, Bei-Jian;Li, Chao-Lun;Fan, Pei-Li;Hou, Jun;He, Nian-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권2호
    • /
    • pp.493-497
    • /
    • 2012
  • This study was conducted to retrospectively evaluate the pattern of contrast enhancement with SonoVue on gray-scale ultrasonography of hepatic angiomyolipoma (HAML). Imaging features of 33 pathologically proven HAML lesions in 33 patients who underwent baseline ultrasound and contrast-enhanced ultrasonography (CEUS) were assessed retrospectively. All lesions were enhanced in the arterial phase and showed whole-tumor filling in. Thirty-two of 33 (97%) lesions showed early positive enhancement in the arterial phase. Twenty-three of these exhibited isoechoic or hyperechoic features in the portal phase. HAML demonstrate characteristic manifestations with SonoVue-enhanced real-time gray-scale ultrasonography.

Contrast Enhanced Ultrasonography and CT Features of Gastrointestinal Stromal Tumor in a Dog

  • Saran Chhoey;Soyeon Kim;Kroesna Kang;Sath Keo;Jihye Choi
    • 한국임상수의학회지
    • /
    • 제40권5호
    • /
    • pp.375-381
    • /
    • 2023
  • A large abdominal mass was incidentally found in a 13-year-old mixed-breed dog and was confirmed to be a cecal gastrointestinal stromal tumor (GIST). Contrast-enhanced ultrasound and post-contrast computed tomography (CT) showed mild contrast enhancement of the mass, indicating low blood flow. The tumor origin was determined to be the cecum by identifying the vessels supplying the mass on post-contrast CT. The exophytic growth of the tumor left the cecal lumen intact without obstruction. This report described the CEUS and CT perfusion of the cecal GIST and perfusion evaluation can help diagnose and characterize GISTs in dogs.

The Utility of Contrast Enhanced Ultrasound and Elastography in the Early Detection of Fibro-Stenotic Ileal Strictures in Children with Crohn's Disease

  • Sarah D. Sidhu ;Shelly Joseph;Emily Dunn;Carmen Cuffari
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제26권4호
    • /
    • pp.193-200
    • /
    • 2023
  • Purpose: Crohn's disease (CD) is a chronic, idiopathic bowel disorder that can progress to partial or complete bowel obstruction. At present, there are no reliable diagnostic tests that can readily distinguish between acute inflammatory, purely fibrotic and mixed inflammatory and fibrotic. Our aim is to study the utility of contrast enhanced ultrasound (CEUS) in combination with shear wave elastography (SWE) to differentiate fibrotic from inflammatory strictures in children with obstructive CD of the terminal ileum. Methods: Twenty-five (19 male) children between 2016-2021 with CD of the terminal ileum were recruited into the study. Among these patients, 22 had CEUS kinetic measurements of tissue perfusion, including wash-in slope (dB/sec), peak intensity (dB), time to peak intensity (sec), area under the curve (AUC) (dB sec), and SWE. In total, 11 patients required surgery due to bowel obstruction. Histopathologic analysis was performed by a pathologist who was blinded to the CEUS and SWE test results. Results: Patients that underwent surgical resection had significantly higher mean area under the curve on CEUS compared to patients responsive to medical therapy (p=0.03). The AUC also correlated with the degree of hypertrophy and the percent fibrosis of the muscularis propria, as determined by histopathologic grading (p<0.01). There was no difference in the mean elastography measurements between these two patient groups. Conclusion: CEUS is a useful radiological technique that can help identify pediatric patients with medically refractory obstructive fibrotic strictures of the terminal ileum that should be considered for early surgical resection.

A Prospective Study on the Value of Ultrasound Microflow Assessment to Distinguish Malignant from Benign Solid Breast Masses: Association between Ultrasound Parameters and Histologic Microvessel Densities

  • Ah Young Park;Myoungae Kwon;Ok Hee Woo;Kyu Ran Cho;Eun Kyung Park;Sang Hoon Cha;Sung Eun Song;Ju-Han Lee;JaeHyung Cha;Gil Soo Son;Bo Kyoung Seo
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.759-772
    • /
    • 2019
  • Objective: To investigate the value of ultrasound (US) microflow assessment in distinguishing malignant from benign solid breast masses as well as the association between US parameters and histologic microvessel density (MVD). Materials and Methods: Ninety-eight breast masses (57 benign and 41 malignant) were examined using Superb Microvascular Imaging (SMI) and contrast-enhanced US (CEUS) before biopsy. Two radiologists evaluated the quantitative and qualitative vascular parameters on SMI (vascular index, morphology, distribution, and penetration) and CEUS (time-intensity curve analysis and enhancement characteristics). US parameters were compared between benign and malignant masses and the diagnostic performance was compared between SMI and CEUS. Subgroup analysis was performed according to lesion size. The effect of vascular parameters on downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4A masses was evaluated. The association between histologic MVD and US parameters was analyzed. Results: Malignant masses were associated with a higher vascular index (15.1 ± 7.3 vs. 5.9 ± 5.6), complex vessel morphology (82.9% vs. 42.1%), central vascularity (95.1% vs. 59.6%), penetrating vessels (80.5% vs. 31.6%) on SMI (all, p < 0.001), as well as higher peak intensity (37.1 ± 25.7 vs. 17.0 ± 15.8, p < 0.001), slope (10.6 ± 11.2 vs. 3.9 ± 4.2, p = 0.001), area (1035.7 ± 726.9 vs. 458.2 ± 410.2, p < 0.001), hyperenhancement (95.1% vs. 70.2%, p = 0.005), centripetal enhancement (70.7% vs. 45.6%, p = 0.023), penetrating vessels (65.9% vs. 22.8%, p < 0.001), and perfusion defects (31.7% vs. 3.5%, p < 0.001) on CEUS (p ≤ 0.023). The areas under the receiver operating characteristic curve (AUCs) of SMI and CEUS were 0.853 and 0.841, respectively (p = 0.803). In 19 masses measuring < 10 mm, central vascularity on SMI was associated with malignancy (100% vs. 38.5%, p = 0.018). Considering all benign SMI parameters on the BI-RADS assessment, unnecessary biopsies could be avoided in 12 category 4A masses with improved AUCs (0.500 vs. 0.605, p < 0.001). US vascular parameters associated with malignancy showed higher MVD (p ≤ 0.016). MVD was higher in malignant masses than in benign masses, and malignant masses negative for estrogen receptor or positive for Ki67 had higher MVD (p < 0.05). Conclusion: US microflow assessment using SMI and CEUS is valuable in distinguishing malignant from benign solid breast masses, and US vascular parameters are associated with histologic MVD.

Value of Intraplaque Neovascularization on Contrast-Enhanced Ultrasonography in Predicting Ischemic Stroke Recurrence in Patients With Carotid Atherosclerotic Plaque

  • Zhe Huang;Xue-Qing Cheng;Ya-Ni Liu;Xiao-Jun Bi;You-Bin Deng
    • Korean Journal of Radiology
    • /
    • 제24권4호
    • /
    • pp.338-348
    • /
    • 2023
  • Objective: Patients with a history of ischemic stroke are at risk for a second ischemic stroke. This study aimed to investigate the relationship between carotid plaque enhancement on perfluorobutane microbubble contrast-enhanced ultrasonography (CEUS) and future recurrent stroke, and to determine whether plaque enhancement can contribute to risk assessment for recurrent stroke compared with the Essen Stroke Risk Score (ESRS). Materials and Methods: This prospective study screened 151 patients with recent ischemic stroke and carotid atherosclerotic plaques at our hospital between August 2020 and December 2020. A total of 149 eligible patients underwent carotid CEUS, and 130 patients who were followed up for 15-27 months or until stroke recurrence were analyzed. Plaque enhancement on CEUS was investigated as a possible risk factor for stroke recurrence and as a possible adjunct to ESRS. Results: During follow-up, 25 patients (19.2%) experienced recurrent stroke. Patients with plaque enhancement on CEUS had an increased risk of stroke recurrence events (22/73, 30.1%) compared to those without plaque enhancement (3/57, 5.3%), with an adjusted hazard ratio (HR) of 38.264 (95% confidence interval [CI]:14.975-97.767; P < 0.001) according to a multivariable Cox proportional hazards model analysis, indicating that the presence of carotid plaque enhancement was a significant independent predictor of recurrent stroke. When plaque enhancement was added to the ESRS, the HR for stroke recurrence in the high-risk group compared to that in the low-risk group (2.188; 95% CI, 0.025-3.388) was greater than that of the ESRS alone (1.706; 95% CI, 0.810-9.014). A net of 32.0% of the recurrence group was reclassified upward appropriately by the addition of plaque enhancement to the ESRS. Conclusion: Carotid plaque enhancement was a significant and independent predictor of stroke recurrence in patients with ischemic stroke. Furthermore, the addition of plaque enhancement improved the risk stratification capability of the ESRS.

유방자기공명영상에서 추가적으로 발견된 유방 병소에 대한 조영증강 초음파의 정량적 분석을 통한 진단 능력 평가와 동적 조영증강 유방 자기공명영상 결과와의 비교 (Assessment of Additional MRI-Detected Breast Lesions Using the Quantitative Analysis of Contrast-Enhanced Ultrasound Scans and Its Comparability with Dynamic Contrast-Enhanced MRI Findings of the Breast)

  • 이세영;우옥희;신혜선;송성은;조규란;서보경;황순영
    • 대한영상의학회지
    • /
    • 제82권4호
    • /
    • pp.889-902
    • /
    • 2021
  • 목적 자기공명영상에서 추가적으로 발견된 조영증강 병소에 대한 조영증강 초음파의 진단능력을 평가하고 조영증강 초음파의 정량 분석을 사용하여 유방 동적 조영증강 자기공명영상과 유사한 운동 패턴 결과를 얻을 수 있는지 분석하였다. 대상과 방법 단일 센터 전향적 연구로 진행하였고, 총 71개의 자기공명영상에서 추가적으로 발견된 조영증강 병소가 포함되었다. 이러한 병소에 대해 조영증강 초음파를 시행하였고 Breast Imaging-Reporting and Data System (이하 BI-RADS)에 따라 분류하였다. 그리고 모든 병소의 BI-RADS 분류를 조직학적 결과와 비교하여 조영증강 초음파의 민감도, 특이도 및 진단 정확도를 계산하였다. 조영증강 초음파와 동적 조영증강 자기공명영상의 운동 패턴사이의 일치도는 가중 카파 분석을 사용하여 평가되었다. 결과 조영증강 초음파에서 총 46개의 병소가 BI-RADS 4B, 4C, 5로 분류되었고, 25개의 병소가 BI-RADS 3, 4A로 분류되었다. 자기공명영상에서 추가적으로 발견된 조영증강 병소에 대한 조영증강 초음파의 진단 능력은 84.9%의 민감도, 94.4%의 특이도 및 97.8%의 긍정적 예측값으로 우수하였다. 총 57/71 (80%) 병소는 조영증강 초음파와 동적 조영증강 자기공명영상 운동 패턴 결과가 일치하였고 가중 카파 값 0.66으로 좋은 일치도를 나타냈다. 부분 군 분석에서 양성 병소는 우수한 일치를 보였고(가중 카파 값 = 0.84), 관내암종은 좋은 일치를 보였다(가중 카파 값 = 0.69). 결론 MRI에서 추가 검출된 유방 결절에 대한 조영증강 초음파의 진단 능력은 우수했다. 양성 및 관내암종 병소에서 동적 조영증강 자기공명영상과 조영증강 초음파의 운동 패턴 결과는 좋은 일치도를 보였다.

조영증강 초음파 진단에서 호흡에 의한 흔들림을 보정한 파라미터 영상 생성 기법 (Parametric Imaging with Respiratory Motion Correction for Contrast-Enhanced Ultrasonography)

  • 김호준;조윤석
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제9권2호
    • /
    • pp.69-76
    • /
    • 2020
  • 본 연구에서는 조영증강 초음파 영상에서 조영효과 확산 패턴과 동적 혈류 패턴을 가시화 하는 방법론을 제시한다. 세부적으로 조영증강 초음파 데이터에서 조영제의 전이시간, 최대 명도변화, 조영효과의 감쇄 시간 등과 같은 진단 파라미터를 영상으로 생성하는 기법을 제안한다. 간병변 진단과 같은 의료 진단에서 조영제의 전이와 확산 속도는 매우 중요한 요소가 된다. 이에 본 연구에서는 조영효과의 확산 패턴을 하나의 영상으로 표현하는 방법을 제시하였다. 이 과정에서 호흡에 의한 흔들림으로 인하여 영상의 정확도가 저하시키는 현상을 개선하기 위하여 호흡주기에 따른 동적 가중치와 모멘텀 요소를 사용하는 영상추적 기법을 제안하였다. 총 72개의 조영증강 데이터를 사용한 실험을 통하여, 제안된 기법이 초음파진단에서 육안 판별의 한계를 극복할 수 있게 하고, 호흡에 의한 흔들림을 보정함으로써 진단 파라미터의 신뢰도를 향상시킬 수 있음을 보인다.

Endovascular embolization of persistent liver injuries not responding to conservative management: a narrative review

  • Simon Roh
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.165-171
    • /
    • 2023
  • Trauma remains a significant healthcare burden, causing over five million yearly fatalities. Notably, the liver is a frequently injured solid organ in abdominal trauma, especially in patients under 40 years. It becomes even more critical given that uncontrolled hemorrhage linked to liver trauma can have mortality rates ranging from 10% to 50%. Liver injuries, mainly resulting from blunt trauma such as motor vehicle accidents, are traditionally classified using the American Association for the Surgery of Trauma grading scale. However, recent developments have introduced the World Society of Emergency Surgery classification, which considers the patient's physiological status. The diagnostic approach often involves multiphase computed tomography (CT). Still, newer methods like split-bolus single-pass CT and contrast-enhanced ultrasound (CEUS) aim to reduce radiation exposure. Concerning management, nonoperative strategies have emerged as the gold standard, especially for hemodynamically stable patients. Incorporating angiography with embolization has also been beneficial, with success rates reported between 80% and 97%. However, it is essential to identify the specific source of bleeding for effective embolization. Given the severity of liver trauma and its potential complications, innovations in diagnostic and therapeutic approaches have been pivotal. While CT remains a primary diagnostic tool, methods like CEUS offer safer alternatives. Moreover, nonoperative management, especially when combined with angiography and embolization, has demonstrated notable success. Still, the healthcare community must remain vigilant to complications and continuously seek improvements in trauma care.

In Vivo Experimental Study on the Effects of Fluid in Increasing the Efficiency of Radiofrequency Ablation

  • Sun, Yi-Xin;Cheng, Wen;Han, Xue;Liu, Zhao;Wang, Qiu-Cheng;Shao, Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권14호
    • /
    • pp.5799-5804
    • /
    • 2014
  • Background: Radiofrequency ablation (RFA) is the most widely used and studied method internationally for the local treatment of liver tumors. However, the extension of coagulation necrosis in one RFA procedure is limited and incomplete coverage of the damaged area can lead to a high local recurrence rate. Objective: In this study, we compared the effects of different solutions in enhancing hepatic radiofrequency by establishing a rabbit VX2 liver cancer model. We also determined the optimal solution to maximise effects on the extent of RFA-induced coagulation necrosis. Methods: Thirty VX2 tumor rabbits were randomly assigned to five groups: group A, RFA alone; group B, RFA with anhydrous ethanol injection; group C, RFA with 5% hypertonic saline injection; group D, RFA with lidocaine injection; and group E, RFA with a mixed solution. Routine ultrasound examinations and contrast-enhanced ultrasound (CEUS) of the ablation areas were performed after RFA. Then, we measured the major axis and transverse diameter and compared the areas of coagulation necrosis induced by RFA. Results: The mean ablation area range increased in groups B, C and especially E, and the scopes were greater compared with group A. Preoperative application of anhydrous ethanol, hypertonic saline, lidocaine and the mixed solution (groups B, C, D and E, respectively) resulted in larger coagulation necrosis areas than in group A (p<0.05). Among the groups, the coagulation necrosis areas in group E was largest, and the difference was statistically significant compared with other groups (p<0.05). Pathological findings were consistent with imaging results. Conclusions: A mixture of dehydrated alcohol, hypertonic saline and lidocaine injected with RFA increases the extent of coagulation necrosis in the liver with a single application, and the mixed solution is more effective than any other injection alone.

전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구 (The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis)

  • 황성일;이학종;김길중;정진행;정현숙;전종준
    • Ultrasonography
    • /
    • 제32권2호
    • /
    • pp.132-142
    • /
    • 2013
  • 목적: 전립선암 (PC-3, LNCaP)의 이종이식쥐 모델에서 초음파 조영제를 이용하여 측정한 시간-신호강도 곡선을 통해 얻은 역학적 변수를 조직병리적 변수와 비교하고자 하였다. 대상 및 방법: 20마리의 누드마우스에 인간전립선암세포(15 PC-3, 5 LNCaP)를 다리에 주입하여 이종이식쥐 모델을 제작하였다. 이후 $500{\mu}L$의 2세대 초음파 조영제인 Sonovue를 후안와정맥을 통해 주입하였다. 관심영역은 종양의 전체를 포함할 수 있게 그린 후, 시간-신호강도 곡선을 얻고 이를 감마변량함수에 적합시켰다. 최고신호강도(A), 최고도달시간 (Tp), 최고유입률 (washin), 최고 유출률 (washout), 50초까지의 곡선하면적 ($AUC_{50}$), 유입기면적 ($AUC_{in}$), 유출기면적 ($AUC_{out}$) 등을 감마변량함수에서 도출하였다. VEGF와 CD31에 대한 면역조직화학염색법을 시행하였고, 종양부피, 시야당 VEGF 면적백분율, CD31 양성 미세혈관수 (MVD) 등을 계산한 후 이를 시간신호강도에서 얻은 역학적 변수와 상관성을 조사하였다. 결과: PC-3 와 LNCaP간 동적 및 조직병리학적 변수의 통계적 차이는 없었다. MVD는 A (r=0.625, p=0.003), washin (r=0.462, p=0.040), AUC (r=0.604, p=0.005), $AUC_{out}$ (r=0.587, p=0.007) 과 유의한 상관관계를 보였다. 또한 종양부피와 $AUC_{50}$ (r=0.481, p=0.032), washin(r=0.662, p=0.001), $AUC_{out}$ (r=0.547, p=0.012) 도 유의한 양의 상관관계를 보였으며, washout은 MVD (r=-0.454, p=0.044) 및 종양부피 (r=-0.464, p=0.039)에 모두 음의 상관관계를 보였다. 그러나 시야당 VEGF 면적백분율은 역학적 변수와 유의한 상관관계를 보이지 않았다. 결론: MVD는 다수의 역학적 변수와 상관관계를 보였다. 초음파 조영제를 이용한 초음파는 전립선암 동물모델에서 종양의 혈관성을 예측할 수 있는 가능성을 보였다.